11 | Appendix
STOBER
52
11/2019 | ID 442710.03
11.2.3
Error codes
The following table shows the possible error codes along with the coding of the cause of error.
Value
0 hex
Parameter unfamiliar or configuration stopped
1 hex
Access to read-only parameter
2 hex
Access to parameter with value outside the limit
3 hex
Access to unavailable subindex (array parameter)
B hex
User level not reached
11 hex
Parameter may not be changed in the current device state; deactivate release
14 hex
Invalid value within maximum limits; only occurs in the case of selection parameters with a broken
definition range
16 hex
One or more incorrect values in the attribute, Number_of_elements, Parameter_number and subindex
elements
17 hex
Invalid format specification
18 hex
Contrary value in the Number_of_elements and Number_of_values elements
21 hex
Invalid Request_ID = Service not supported; applies to errors in the header of the request block
A5 hex
Error cannot be specified in more detail
B0 hex
Parameter service currently not possible or valid parameter description not present
B2 hex
Unfamiliar parameter address (parameter or element does not exist)
B3 hex
Read/write access not possible for specified parameter address
B9 hex
Parameter service: Value in definition gap (observe ENUM list)
BA hex
Parameter service: Clash with other values
C0 hex
Parameter service: Error in pre-read function
C1 hex
Parameter service: Error in post-write function; value has already been received
Tab. 14: RDREC, WRREC: Error codes