Principle of operation
STP1612PW05
14/35
Doc ID 15819 Rev 4
6
Principle of operation
Table 12.
Control command
Signals combination
Description
Command name
LE
Number of CLK
rising edge when
LE is asserted
The action after a falling edge of LE
Data latch
High
1
Serial data are transferred to the buffers
Global latch
High
2 or 3
Buffer data are transferred to the comparators
Read configuration
High
4 or 5
Move out “configuration register” to the shift
register
Enable “error
detection”
High
6 or 7
Detect the status of each output’s LED
Read “error status
code”
High 8
or
9
Move out “error status code” of 16 outputs to
the shift registers
Write configuration
High
10 or 11
Serial data are transferred to the
“configuration register”
Reset to 16-bit shift
register length
High
12 or 13
Set to 16-bit the shift register length