Stirling PA19W Скачать руководство пользователя страница 2

2

AFTER SALES SUPPORT

1300 886 649

[email protected]

AUS

MODEL: PA19W   PRODUCT CODE: 703227    11/2020

Important safety precautions concerning refrigerant R290

WARNING: Combustible & Dangerous

This symbol alerts you to take care as the appliance contains 
a flammable refrigerant: R290 (propane). Take extra care when 
installing the unit and when carrying out maintenance. R290 is 
a colourless and odourless hydrocarbon gas. It is an efficient 
refrigerant with a low Global Warming Potential (GWP) and no 
potential for ozone depletion. 

While R290 is highly flammable, there will be no risk of burning and explosion if the 
appliance is properly installed and maintained following all instructions and safety 
advice in the supplied manuals.

R290-Specific Safety Advice

WARNING! 

•  The room in which this air conditioner is installed must have a minimum area of more 

than 4m

2

. (This unit is designed for use in a room of approximately 10–14m

size.)

•  The appliance shall be stored in a well-ventilated area without continuously 

operating sources, such as open flames, an operating ignition gas appliance or an 
operating electric heater. Do not expose the appliance to high heat, sparks and open 
flames.

•  Do not pierce or burn the appliance. 

•  Do not use means to accelerate the defrosting process or to clean, other than those 

recommended by the manufacturer.

•  Be aware that refrigerants may not contain an odour. 

•  The ratings of the fuse installed in the built-in control unit are T, 2AL, 250V~.

•  This air conditioner has been fully charged with refrigerant at the factory. Should a 

recharge become necessary, it may only be recharged by a professional installer. 

•  Maintenance must only be carried out by properly qualified, authorised personnel. If 

the appliance requires maintenance or service, contact our after sales support centre. 

•  The service technician must strictly comply with: 

– all safety instructions in the manual provided with the appliance 
– all relevant provisions of gas-related local laws and regulations.

•  After servicing the appliance, the service technician must: 

– check that air cannot enter the refrigerant system 
– check for refrigerant leaks when moving the air conditioner 
–  carry out a test cycle under controlled conditions after installing the unit and record 

the operating data.

Содержание PA19W

Страница 1: ...AFTER SALES SUPPORT 1300 886 649 info tempo org AUS MODEL PA19W PRODUCT CODE 703227 11 2020 Model Number PA19W Wi Fi Portable Air Conditioner 1 9kW Cooling SERVICE MANUAL ...

Страница 2: ...as open flames an operating ignition gas appliance or an operating electric heater Do not expose the appliance to high heat sparks and open flames Do not pierce or burn the appliance Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer Be aware that refrigerants may not contain an odour The ratings of the fuse installed in the built in ...

Страница 3: ...stallation of pipe work shall be kept to a minimum Pipe work shall be protected from physical damage and shall not be installed in an unventilated space Compliance with national gas regulations shall be observed Mechanical connections made by brazing or welding shall be accessible for maintenance purposes Table Minimum room area m2 R290 LFL kg m3 h0 m Charge amount M kg Minimum room area m2 0 152k...

Страница 4: ...riate refrigerant detector prior to and during work to ensure the technician is aware of potentially toxic or flammable atmospheres Ensure that the leak detection equipment being used is suitable for use with all applicable refrigerants i e non sparking adequately sealed or intrinsically safe 1 4 Presence of fire extinguisher If any hot work is to be conducted on the refrigeration equipment or any...

Страница 5: ... being used the secondary circuit shall be checked for the presence of refrigerant marking to the equipment continues to be visible and legible Markings and signs that are illegible shall be corrected refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components unless the components are const...

Страница 6: ...th the manufacturer s specifications NOTE The use of silicon sealant can inhibit the effectiveness of some types of leak detection equipment Intrinsically safe components do not have to be isolated prior to working on them 5 Repair to intrinsically safe components 5 1 Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible...

Страница 7: ... by means of shut off valves in a part of the system remote from the leak Oxygen free nitrogen OFN shall then be purged through the system both before and during the brazing process 9 Removal and evacuation 9 1 When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However for flammable refrigerants it is important that best practi...

Страница 8: ...ried out prior to leaving the site 11 Decommissioning Before carrying out this procedure it is essential that the technician is completely familiar with the equipment and all its detail It is recommended good practice that all refrigerants are recovered safely Prior to the task being carried out an oil and refrigerant sample shall be taken in case analysis is required prior to re use of reclaimed ...

Страница 9: ... are employed Ensure that the correct number of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant i e special cylinders for the recovery of refrigerant Cylinders shall be complete with pressure relief valve and associated shut off valves in good working order Empty recovery cylinders a...

Страница 10: ... specially equipped for servicing units with flammable refrigerants Ensure sufficient ventilation at the repair place Be aware that malfunction of the equipment may be caused by refrigerant loss and a refrigerant leak is possible Discharge capacitors in a way that won t cause any spark The standard procedure to short circuit the capacitor terminals usually creates sparks Reassemble sealed enclosur...

Страница 11: ... spark Remove the refrigerant If the recovery is not required by national regulations drain the refrigerant to the outside Take care that the drained refrigerant will not cause any danger In doubt one person should guard the outlet Take special care that drained refrigerant will not float back into the building Evacuate the refrigerant circuit Purge the refrigerant circuit with nitrogen for 5 min ...

Страница 12: ...ecommend that you ask your licensed service technician to fill in the details below so you have them on record should you need to contact the technician in the future Please fill in the details below Name of service technician Licence number Date of service Signature Service Manual Version 1 1 July 2020 Technical specifications Model PA19W Cooling capacity 1 9kW Refrigerant quantity R290 140g Perm...

Отзывы: