Cleaning the radiator and check-
ing the radiator for leak tightness
WARNING
Risk of burns due to hot components!
Cooling system components can be so hot that direct
contact may burn the skin.
–
Ensure that the cooling system has cooled down.
–
Do not grasp or touch hot components.
–
In the event of burns, seek first aid immediately.
CAUTION
Risk of component damage due to overheating!
A cooling system protects the power electronics and
the hydraulic oil against overheating. Loss of coolant
from leaking coolant hoses or from the radiator re-
duces the cooling capacity and can cause compo-
nents to overheat. If the cooling fluid level is low, this
indicates a leak in the cooling system.
–
Check the cooling system for leak tightness.
–
Park the truck securely.
–
Remove the cover on the left-hand side.
–
Check the cooling fluid level.
–
Remove the rear cover and clean the ex-
haust air grille.
–
Clean the radiator grille (1), the exhaust air
funnel (2) and the water drain (3) using a
suitable brush or blow them out using com-
pressed air (max. 2 bar).
–
To clean the radiator behind (4), unscrew
the radiator grille (1) at the screw joints (5)
and remove the radiator grille.
–
Clean the radiator fins.
–
Check the radiator and the cooling fluid ho-
ses for leak tightness.
–
Tighten clips at leaking hose connections.
–
Check whether the leakage has been elimi-
nated. If not, notify the authorised service
centre.
–
Fit the radiator grille and tightly screw on
the radiator grille.
6341_003-029
2
3
1
4
5
Maintenance
5
Preserving operational readiness
350
56358042501 EN - - 11
Содержание RX60-60
Страница 2: ......
Страница 13: ...1 Foreword ...
Страница 20: ...Overview Foreword 1 Your truck 8 56358042501 EN 11 ...
Страница 41: ...2 Safety ...
Страница 55: ...the truck correctly and without the risk of acci dents Safety 2 Residual risk 43 56358042501 EN 11 ...
Страница 70: ...Safety 2 Emissions 58 56358042501 EN 11 ...
Страница 71: ...3 Overviews ...
Страница 83: ...4 Operating ...
Страница 231: ... Load capacity Q kg 1 Lift height h mm 2 Load distance C mm 3 Operating 4 Attachments 219 56358042501 EN 11 ...
Страница 336: ...Operating 4 Decommissioning 324 56358042501 EN 11 ...
Страница 337: ...5 Maintenance ...
Страница 344: ...Maintenance 5 General maintenance information 332 56358042501 EN 11 ...
Страница 381: ...6 1000 hour maintenance annual mainte nance ...
Страница 384: ...1000 hour maintenance annual maintenance 6 Checking the reversible fork arms 372 56358042501 EN 11 ...
Страница 385: ...7 Technical data ...
Страница 398: ...Technical data 7 Fuse assignment 386 56358042501 EN 11 ...
Страница 407: ......
Страница 408: ...STILL GmbH 56358042501 EN 11 ...