4
Use
Handling the battery
If the charger stays connected to the mains,
it restarts a charging cycle every 48 hours
after the end of the previous charge in order to
compensate for self-discharge.
Partial recharging
The charger adapts automatically to the
battery discharge situation and therefore
allows any type of partial charging to be carried
out ("opportunity charging").
The overcharging calculation takes into
account partial recharging. The mixture is
always sufficient, without needless water
consumption, which prevents premature
wear of the batteries (often due to overlong
charging periods) and reduces the need for
maintenance.
Protection during charging
Mains micro-break protection
If the mains power is cut off, all the existing
charging parameters are stored in the memory
for 13 minutes. As soon as the mains power
returns, charging resumes from the point (I, U)
at which it was cut off, with the number of Ah
already injected stored in the memory.
If the cut-off period is longer than 13 minutes
(the truck could have been used), a complete
charging cycle is initialised.
Time protection
If the duration of phases I1 + P + U is more
than 16 hours, the charger automatically
stops. This can happen when a battery has
a short-circuited component. Simply reset the
mains to clear the fault.
Temperature safety
As the charger is cooled by ventilation, the air
inlets and outlets must never be blocked.
The fan runs when the mains power is con-
nected. It stops when charging is complete or
when the mains power is disconnected.
The charger supplies reduced power if the
ambient temperature exceeds the usage
temperature range in order to protect itself
(the charging period will be extended in this
case).
The charger stops if the micro-controller
detects a temperature measurement fault.
Using the on-board charger
NOTE
The charger is compatible with wet lead and
gel batteries with a maximum capacity of
400 Ah.
CAUTION
Risk of damaging the battery
Do not disconnect the battery connector during
charging (green indicator light flashes).
The truck cannot be operated during charging.
The on-board charger is intended for recharg-
ing the battery.
– Switch off the truck.
88
11638011651 EN - 09/2019
Содержание EXD-SF 20
Страница 1: ...Original instructions Double pallet stacker EXD SF 20 0313 0346 11638011651 EN 09 2019 ...
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 11: ...1 Introduction ...
Страница 19: ...2 Safety ...
Страница 28: ...2 Safety Safety tests 18 11638011651 EN 09 2019 ...
Страница 29: ...3 Overviews ...
Страница 40: ...3 Overviews Markings 30 11638011651 EN 09 2019 ...
Страница 41: ...4 Use ...
Страница 113: ...5 Maintenance ...
Страница 139: ...6 Technical specifications ...
Страница 140: ...6 Technical specifications EXD SF 20 datasheet EXD SF 20 datasheet 130 11638011651 EN 09 2019 ...
Страница 148: ......
Страница 149: ......
Страница 150: ...STILL GmbH 11638011651 EN 09 2019 ...