Maintenance
5
Hydraulic systems
– Remove the hood of the technical compart-
ment.
To ensure correct operation of the truck
functions, the oil level must be between the
minimum mark (3) and maximum mark (2) on
the tank.
– Remove the plug (1). If necessary, top up
via the opening.
– Refit the plug (1) afterwards.
CAUTION
Risk of damage to hydraulic components
Only use hydraulic oil that complies with the manu-
facturer's specifications (see table of recommen-
ded lubricants).
– Refit the hood of the technical compart-
ment.
– Reconnect the battery connector.
– Return the truck to service.
Checking the controlled stabiliser
hydraulic system for leaks
– Switch off the truck and disconnect the
battery connector.
– Remove the hood of the technical compart-
ment.
– Inspect the stabiliser hydraulic system:
• Tank
• Rigid pipes
• Connections from the stabiliser directional
control valve block to the cylinders
– Check the tank for leaks.
– Tighten the swivel joints on the cylinders if
necessary.
– Check the cylinders for leaks.
– Check that the rigid pipes are attached
correctly and show no signs of friction wear.
– Refit the hood of the technical compart-
ment.
– Return the truck to service.
11638011651 EN - 09/2019
123
Содержание EXD-SF 20
Страница 1: ...Original instructions Double pallet stacker EXD SF 20 0313 0346 11638011651 EN 09 2019 ...
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 11: ...1 Introduction ...
Страница 19: ...2 Safety ...
Страница 28: ...2 Safety Safety tests 18 11638011651 EN 09 2019 ...
Страница 29: ...3 Overviews ...
Страница 40: ...3 Overviews Markings 30 11638011651 EN 09 2019 ...
Страница 41: ...4 Use ...
Страница 113: ...5 Maintenance ...
Страница 139: ...6 Technical specifications ...
Страница 140: ...6 Technical specifications EXD SF 20 datasheet EXD SF 20 datasheet 130 11638011651 EN 09 2019 ...
Страница 148: ......
Страница 149: ......
Страница 150: ...STILL GmbH 11638011651 EN 09 2019 ...