Fuse replacement
●
Turn off the truck and perform the prelimi-
nary maintenance operations.
CAUTION
Before replacing the fuse, eliminate the cause that
led to its blowing. The blown fuse must only be re-
placed with a fuse of the same amperage. Do not
tamper with the truck's electrical system.
●
Access the fuses as indicated in the "Inter-
nal Accessibility" section.
Service fuses (1) and (2)
●
Remove the cover and replace the blown
fuse, then replace the cover.
Power fuses (3) and (4)
●
Loosen the screws, replace the fuses and
retighten the screws.
Fuse values
●
(1) Fuse = 7.5 A
●
(2) Fuse = 5 A
●
(3) Traction motor protection fuse = 200 A
●
(4) Lifting motor protection fuse = 150 A