34
ALARM
Here you can switch the main alarm on and off. When the main alarm is off, the LED in the alarm key will flash
to indicate that the main alarm is off. No alarm is generated anymore.
Test (alarm test)
Test “yes”
: This enables you to test the operation of
the alarm relay (siren). If you enter "yes" in the line
Test
, the alarm relay (siren) will be switched on for
10 seconds.
You can clear the alarm test time by setting "no" in
the line
Test
.
(alarm temporary off)
Off “yes”:
This enables you to temporarily switch off
the alarm (siren). This does not apply to the hardware
alarms which cannot be switched off temporarily. The
main alarm is switched off for 30 minutes (the lamp
will blink irregularly). The main alarm is switched on
automatically again after 30 minutes. The alarm relay
will then de-energize again, causing an alarm, if the
cause of the alarm has not been removed.
You can clear the temporary alarm deactivation time
by setting "no" in the line
.
If no access code has been installed or if you have already entered the correct access code, you can switch off
the main alarm.
Installation errors such as “Output already assigned”, “Incorrect output type”, “Input
already assigned” etc. have to be solved first before putting the system into operation.
Attention: NEVER FORGET TO SWITCH THE ALARM BACK "ON"
when you have switched this feature off
'temporarily', e.g. to solve a problem. Failing to switch it back on may have adverse effects for
humans, animals, equipment or property.
Preferably use the
(alarm retard) function to solve a problem.
LATEST ALARMS HOUSE
The last 5 alarm causes which caused the alarm relay to de-energize will be stored. The date and time of the
alarm are displayed in addition to its cause.
Alarm 0:
The cause of the
alarm that occurred the last
is shown behind “Alarm 0”. In addition, the time until
which the alarm is/was active is shown.
You can call up the data of the previous alarms by pressing the Arrow down key.
ALARM CODES
Alarm code
Description
Alarm unknown (xxx)
An unknown and non-documented alarm code has occurred. Note down the
number that is displayed and contact your supplier.
Beginning new day in period The “Beginning new day” time is in a period; this is not allowed. The “
Beginning
new day” time MUST BE BEFORE the first period.
CO2 sensor faulty
The CO
2
sensor value measured is outside the preset limits
CO2 too high
The CO
2
measured is higher than the maximum alarm limit calculated
CO2 too low
The CO
2
measured is below the minimum alarm limit calculated