Modern poultry farming requires an optimum climate in the houses to achieve good operating results. As a rule,
this is achieved by using a mechanical ventilation system. Important in this respect is the air supply to the
animals and the creation of proper air circulation. The air distribution in the house is strongly influenced by the
type of air supply system. Effective ventilation controls, as are integrated in the PL-9000 poultry computer, can
achieve a good air quality at animal level with a low ventilation flow rate. It speaks for itself that good climate
control contributes to the animals' well-being.
The PL-9000 poultry computer enables you to fulfil virtually all your climate control wishes. The poultry
computer has practically all possible ventilation controls which are featured in modern poultry farming. The
poultry computer controls the climate in the house in such a way that the correction ratio between temperature
and ventilation is always guaranteed. To ensure that the climate in the house develops along with the growth of
your animals, the poultry computer has growth curves. By taking the influence of the weather into account, the
climate in the house can be corrected depending on the weather conditions.
In the event of a power failure, excessive temperature variation or excessive ventilation variation, the alarm will
be activated.
Since every situation is different, in daily practice only the control functions applicable to your specific situation
will be activated. This makes the operation of the poultry computer very easy and transparent.
VENTILATION GROUPS
The PL-9000 poultry computer has a maximum of 3 ventilation groups divided into:
1x main ventilation group
2x additional ventilation groups
Every ventilation group can be subdivided into a maximum of 2 ventilation controls. All ventilation controls in a
group make use of the same settings, i.e. settings per ventilation group, but have their own separate inputs and
outputs and are controlled individually.
Main ventilation group
The 1
st
ventilation control in this group is the main ventilation; this serves as the reference for house
temperature and pressure control compensation. The 2
nd
and 3
rd
ventilation controls in this group are only
switched on in support of the first control and they both have their own adjustable initial percentages. All
ventilation controls have an adjustable ventilation capacity (m
3
/h) which is combined to form the total
ventilation capacity of the main ventilation group.