1
USER MANUAL
FOR THE
PL-9000(-i) POULTRY COMPUTER
V 01.48.0
PL-9000(-i)
Страница 1: ...1 USER MANUAL FOR THE PL 9000 i POULTRY COMPUTER V 01 48 0 PL 9000 i...
Страница 2: ...sure to have all necessary data at hand To ensure a speedy solution to the malfunction and to avoid any misunderstandings it is advisable to note down the cause and the circumstances in which the malf...
Страница 3: ...3 Cooling 14 Miscellaneous controls 14 Compensations climate control 15 Growth curves 21 Temperature overview 22 Alarm 22 House status 24 SILOS 25 Silo contents 25 Silo status 25 Fillet 25 COUNTERS 26...
Страница 4: ...sensor from the room and store it somewhere safe before cleaning the room Also screw the protection cap onto the plug of the extension cable to prevent water from penetrating into the plug When conne...
Страница 5: ...into account the climate in the house can be corrected depending on the weather conditions In the event of a power failure excessive temperature variation or excessive ventilation variation the alarm...
Страница 6: ...sing the timer Maximum 3 timers for dosage feed water and or for light control can be installed If the timer is assigned to a 0 10V input it can be used to create a light control maximum 1 light contr...
Страница 7: ...can call up the remaining settings and or measurements using the up and down cursor keys KEYBOARD Caution 2 3 1 Only press the keys with the tip of your finger Sharp objects such as a pen pencil or s...
Страница 8: ...to remove a breakpoint period provided that there is at least one period breakpoint The number of breakpoints periods is adjusted automatically 2 Function keys graphic alarm previous next control etc...
Страница 9: ...30 minutes The alarm relay will then de energize again causing an alarm if the cause of the alarm has not been removed You can clear the temporary alarm deactivation time by setting no in the line If...
Страница 10: ...f 2 001 Alarm in house alarm delay time is not yet elapse 2 001 Alarm in house alarm delay time is elapse 2 001 Main alarm is switch off Alarm 3 Heat request in house 3 No heating installed 3 All heat...
Страница 11: ...the house in use or out of use using the house status In use The poultry computer carries out its control operation in accordance with the settings Not in use All control alarm and temperature monito...
Страница 12: ...independently of the preset house temperature VENTILATION GROUPS The number of menu options in the Ventilation groups menu varies depending on the type and the number of ventilation groups Please note...
Страница 13: ...cursor is placed on or and you push the confirmation key the curve for the settings concerned will be displayed You may change the curve settings or switch off the curve Press the cancel key to retur...
Страница 14: ...l ventilation If the flap has opened too wide this leads to a cold drop in the house Left and Right Bandwidth Minimum Maximum VENTILATION Setting Temperature C Current Calculated The ventilation group...
Страница 15: ...ion control If a pressure alarm occurs the pressure control will be delayed switch off delay time 5x pressure integration time Current flap opening The current flap opening of the ventilation group is...
Страница 16: ...t flap 2 is closing O2 air inlet flap 2 is opening Tcurrent C Tcontrol Min 5 Max 80 80 O2 35 80 0 D2 30 Group Min 5 Max 80 35 30 87 5 75 D2 30 O2 35 Max 80 Group 35 30 Hyst 5 Bandwidth 12 5 Air inlet...
Страница 17: ...4 temperature sensors to a heating control The current temperature is the average of these temperature sensors Current heating In addition to the current heating status this line also shows the calcu...
Страница 18: ...ing cooling you can call up the operating hours of the cooling In addition to today s operating hours the operating hours of the past 7 days and the total number of operating hours are shown as well E...
Страница 19: ...the cooling on page 14 Temperature setting see page 8 Relative or absolute temperature setting Temperature monitoring The temperature monitoring function is activated by your installer The current mea...
Страница 20: ...ture If the user has set a maximum temperature compensation of 0 0 C the temperature compensation is switched off Example Temperature exceeded Current house temperature House temperature setting bandw...
Страница 21: ...nsation minimum ventilation The minimum ventilation can be automatically adjusted to the actual outside temperature As a result a lower minimum ventilation is obtained at low outside temperatures and...
Страница 22: ...re is low and a lower underpressure when the outside temperature is high Example Pressure setting 20 Pascal Compensation pressure 0 3Pa C Starts outside temperature 20 C Current outside temperature 10...
Страница 23: ...mpensation ventilation flap position Absolute Compensation current RH RH compensation start RH compensation factor Relative Compensation current RH RH compensation start RH compensation factor calcula...
Страница 24: ...art influence wind factor Relative Compensation current wind speed influence wind start influence wind factor calculated ventilation 100 Example Absolute Relative Calculated ventilation left 30 30 Cal...
Страница 25: ...the calculated house temperature will immediately be adjusted to the curve setting The settings obtained from a growth curve are recalculated every hour to achieve a more gradual development of the se...
Страница 26: ...e temperature compensation on behalf of alarm The following applies to all controls if the outside temperature rises to above the temperature that has been set the maximum temperature alarm limit will...
Страница 27: ...temperature You can only switch the alarm on off in these screens The alarm limits shown are the calculated alarm limits and depend on such factors as the preset house temperature limits and the pres...
Страница 28: ...n use All controls alarms and temperature monitoring functions are switched off all flaps are closed all timers are switched off In addition in this screen you can switch the growth curve on off and c...
Страница 29: ...reset to 0 automatically Attention You can only enter a positive silo content when you press the enter key any negative values are erased SILO STATUS FILLET This screen shows how much feed has been d...
Страница 30: ...r 2 will be displayed after Today in the Water column etc Day Water counter 1 Water counter 2 Water l Today 1 323 1 376 2 699 Wednesday 1 245 1 235 2 480 Tuesday 1 311 1 314 2 625 Monday 1 047 1 140 2...
Страница 31: ...When the counter is cleared the data for today is also deleted In addition the overviews of the amounts fed and the feeding times of the selected counters or of all counters are deleted ALARM To be ab...
Страница 32: ...ed to the amount setting Feeding stops when the preset amount is reached even if the stop time has not been reached yet A feed dosing alarm is generated if the stop time is reached and the amount has...
Страница 33: ...sity or vice versa is called the RUNNING TIME or Propagation time The running time can be freely adjusted from 0 to 60 minutes Example of a dawn program with lighting delay Contrary to a timer a light...
Страница 34: ...can clear the overviews by deleting the counter readings see page 27 Overview feed timer Overview of the amount fed in which the total amount is shown as well as the amount per animal if animal data i...
Страница 35: ...number to indicate when the settings of the breakpoint have to become active you also set the daily amount per animal in the dosing curve DATE TIME In addition to date and time you can set the First...
Страница 36: ...ct this by entering this as a positive value Lost Today Today s total mortality Lost Total Total shows the total mortality calculated using the mortality of the previous days and of Today Out Today If...
Страница 37: ...u enter yes at New entry The poultry computer uses these Entry date to calculate the animal age Beside that the Entry date is used to fill in the mutation table The poultry computer can store the data...
Страница 38: ...t type Input already assigned etc have to be solved first before putting the system into operation Attention NEVER FORGET TO SWITCH THE ALARM BACK ON when you have switched this feature off temporaril...
Страница 39: ...ime can be simultaneous with the next starting time Output already assigned The output has been assigned to two or more controls Outside sensor faulty Value measured by outside temperature sensor 50 0...
Страница 40: ...ing applies if TC and TF are the number of degrees Celsius and respectively the number of degrees Fahrenheit Absolute Relative F 32 C 9 5 F C 9 5 C F 32 5 9 C F 5 9 19 5 C 32 19 5 9 5 67 1 F 3 1 C 3 1...
Страница 41: ...s and in summer they can result in unwanted heating due to hot air being drawn in from between the roof and the insulating materials for example This will require the fans to work extra hard to enable...
Страница 42: ......