INSTALLATION
Maintenance
EN
GL
ISH
www.stiebel-eltron-usa.com
UltraHot
Plus
™
& UltraHot Premium
™
|
13
16. Maintenance
WARNING Electrocution
Completely disconnect the appliance from the power
supply when performing any work on it.
f
Uninstall the appliance when performing maintenance.
16.1 Draining the appliance
WARNING Burns
Hot water may escape when draining.
f
Before you drain the appliance, unplug the power plug and
flush for at least two minutes until only cold water is coming
out of the hot water outlet of the faucet.
f
Drain the appliance via the connectors.
16.2 Clean the strainer
D00000
9
6
6
8
0
1 Disconnect the push-fit connector
D00000
9
6
6
82
2 Remove the strainer
f
Remove the cold water supply connection.
f
Disconnect the push-fit connector from the appliance.
f
Using pliers, pull the strainer out of the cold water supply
connection.
f
Descale or replace the strainer.
f
Reinstall the strainer, reinstall the push-fit connector, and
reconnect the cold water supply.
17. Specification
17.1 Dimensions and connections
2
ǪÝ
(61)
2
ǪÝ
(61)
4
Ý
(101)
17
11
/
16
Ý
(449)
19
1
/
16
Ý
(484)
7
ǬÝ
(200)
5¾
Ý
(146)
3
9
/
16
Ý
(90)
10
13
/
16
Ý
(274)
16
ǩÝ
(409)
c01
c08
i13
i13
D00000
9
65
7
7
UltraHot Plus/Premium
c01 Cold water supply
Connectors
c06 Hot water outlet
Nozzle
i13
Wall mounting bracket
17.2 Country-specific approvals and certifications
See the type plate for certifications.
17.3 Extreme operating and fault conditions
If the appliance fails, temperatures of up to 212 °F (100 °C) may