12.3 Connecting to a water filter (required in hard
water areas)
!
Property damage
The UltraHot Plus/Premium appliance must be operated
with a water filter when water hardness values are great-
er than or equal to 8.76 gpg (1.5 mmol/l). This will prevent
limescale buildup in the appliance. Using the appliance
without an external water filter at values above these will
void the appliance warranty. Damage to the appliance
caused by limescale or a high mineral concentration is
not covered by the warranty.
In areas with hard water, when water hardness values are greater
than or equal to 8.76 gpg (1.5 mmol/l), the UltraHot Plus/Premium
appliance must be operated with a water filter (not supplied). For
the water filter to work properly, it should be installed between
the wall connection and the faucet.
Note
Follow the filter manufacturer‘s operating and instal-
lation instructions when installing the water filter (not
supplied).
12.3.1 Connecting the recommended water filter and a 3-in-1
kitchen faucet
D00000
97
28
7
2
5
4
3
6
1
1
Cold water supply to the appliance Plastic hose with push-fit connector
2
Hot water outlet on appliance
7
/
16
˝ plastic hose
3
Warm water supply to the faucet
Short flexible hose with red braid
4
Cold water supply to the faucet
Short flexible hose with blue braid
5
Cold water supply to the filter
6
Suggested water filter (not sup-
plied)
12.3.2 Connecting the recommended water filter and single
near-boiling water faucet
4
3
5
2
1
D00000
97
28
8
1
Cold water supply to the appliance Plastic hose with push-fit connector
2
Hot water outlet
7
/
16
˝ plastic hose
3
Cold water supply to the faucet
Short flexible hose with blue braid
4
Cold water supply to the filter
5
Suggested water filter (not sup-
plied)
12.4 Electrical connection
WARNING Electrocution
Carry out all electrical connection and installation work
according to instructions.
!
Property damage
The voltage indicated on the type plate must match the
utility voltage.
f
Note the type plate.
The following electrical connection options are permitted:
- Connection to a freely accessible grounded receptacle with
an appropriate plug.
13. Commissioning
WARNING Electrocution
Commissioning may only be performed by a qualified
contractor in compliance with safety codes.
Note
You must set the weekday and time at initial startup
and after long periods disconnected from power (ap-
prox. 8 hours).