background image

OpEraTiON 

 

General information

www.stiebel-eltron.com 

HSBB 200 S (GB) | 

3

OpEraTiON

1.  General information

The chapters "Special Information" and "Operation" are intended 

for both the user and qualified contractors.
The chapter "Installation" is intended for qualified contractors.

 

Note

Read these instructions carefully before using the appli-

ance and retain them for future reference.

Pass on the instructions to a new user if required.

1.1  Relevant documents

 

 

Operating and installation instructions for the WPM heat 

pump manager

 

 

Operating and installation instructions for the connected 

heat pump

 

 

Operating and installation instructions for all other sys-

tem components

1.2  Safety instructions

1.2.1  Structure of safety instructions

!

 

KEYWORD Type of risk

Here, possible consequences are listed that may result 

from failure to observe the safety instructions.

f

f

Steps to prevent the risk are listed.

1.2.2  Symbols, type of risk

Symbol

Type of risk

 

 

Injury 

 

 

 

Electrocution 

 

 

 

Burns

(burns, scalding) 

1.2.3  Keywords

KEYWOrD

meaning

DANGER 

Failure to observe this information will result in serious 

injury or death.

WARNING 

Failure to observe this information may result in serious 

injury or death.

CAUTION 

Failure to observe this information may result in non-seri-

ous or minor injury.

1.3  Other symbols in this documentation

 

Note

General information is identified by the adjacent symbol.

f

f

Read these texts carefully.

Symbol

meaning

 

 

Material losses

(appliance damage, consequential losses and environmen-

tal pollution)

 

 

Appliance disposal 

 

f

f

This symbol indicates that you have to do something. The ac-

tion you need to take is described step by step.

…

…

These symbols show you the software menu level (in 

this example level 3).

1.4  Information on the appliance

Connections

Symbol

meaning

 

 

Inlet / intake 

 

 

 

Drain / outlet 

 

 

 

Domestic hot water 

 

 

 

DHW circulation 

 

 

 

Heat pump 

 

 

 

Central heating 

 

1.5  Units of measurement

 

Note

All measurements are given in mm unless stated oth-

erwise.

!

!

Содержание 236916

Страница 1: ...OPERATION AND INSTALLATION Cylinder and hydraulic module HSBB 200 S GB...

Страница 2: ...ring diagram 20 16 4 Details on energy consumption 22 16 5 Data table 22 GUARANTEE ENVIRONMENT AND RECYCLING SPECIAL INFORMATION The appliance may be used by children aged 8 and older and persons with...

Страница 3: ...nt the risk are listed 1 2 2 Symbols type of risk Symbol Type of risk Injury Electrocution Burns burns scalding 1 2 3 Keywords KEYWORD Meaning DANGER Failure to observe this information will result in...

Страница 4: ...nce description The appliance comprises a hydraulic module and an integral DHW cylinder and is equipped with a removable front casing The appli ance is connected hydraulically and electrically to the...

Страница 5: ...If you cannot remedy the fault notify your qualified contractor To facilitate and speed up your request provide the number from the type plate 000000 0000 000000 No 000000 0000 000000 Made in Germany...

Страница 6: ...osses Store and transport the appliance at temperatures be tween 20 C to 60 C Handling If possible transport the appliance to the installation site on the non returnable pallet Alternatively transport...

Страница 7: ...ements or steel pipes Material losses The products of corrosion e g rusty sludge can settle in the heating system components and can result in a lower output or fault shutdowns due to reduced cross se...

Страница 8: ...ine Stainless steel copper and plastic are approved materials 11 4 2 Installing the DHW circulation line if applicable A DHW circulation line with external DHW circulation pump can be fitted to the DH...

Страница 9: ...re position so that the heating circuit and the heat exchanger for DHW heating are filled evenly When power is switched on the 3 way diverter valve automatically switches to heating mode To fill or dr...

Страница 10: ...dance with relevant regulations Before any work on the appliance disconnect all poles from the power supply WARNING Electrocution Only use a permanent connection to the power supply Ensure the applian...

Страница 11: ...rol voltage Appliance function Effect of the electric emergency booster heater Mono energetic operation If the heat pump undershoots the dual mode point the electric emergency booster heater safeguard...

Страница 12: ...xtra low voltage X1 1 CAN A L H L H CAN connection for heat pump and WPE heat pump extension X1 2 CAN B L H L H CAN connection for FET remote control and ISG Internet Service Gateway X1 3 Signal Earth...

Страница 13: ...PE 2nd heat source heating X2 13 L N PE L N PE Cooling X2 14 Mixer OPEN N PE Mixer CLOSE 5 N PE 6 Mixer heating circuit 2 X2 14 1 Mixer OPEN X2 14 2 Mixer CLOSE X2 15 Mixer OPEN N PE Mixer CLOSE 5 N P...

Страница 14: ...doors or air ducts Observe the following minimum clearances 2 5 m above the ground and 1 m to the side of windows and doors Installation f f Remove the cover f f Secure the base with the screw suppli...

Страница 15: ...e observe the rules of the relevant Health Safety at Work Act during commissioning For further details check with your local authorising body 13 1 Checks before commissioning the heat pump manager Mat...

Страница 16: ...Condensation caused by the temperature falling below the dew point can lead to material losses HSBB is there fore exclusively approved for area cooling Adjusting the heat pump manager settings for ar...

Страница 17: ...fication Dimensions and connections Checking replacing the protective anode f f Check the protective anode after the first two years of use and replace if necessary Check that the maximum transition r...

Страница 18: ...80 92 92 177 347 432 517 10 20 177 D0000070858 HSBB 200 S GB b01 Entry electrical cables c01 Cold water inlet Male thread G 1 c06 DHW outlet Diameter mm 22 c10 DHW circulation Male thread G 1 2 c12 Sa...

Страница 19: ...m tundish with continuous fall 11 Equipotential bond 12 Drain valve 13 Cylinder 14 DHW outlet 15 T P valve 16 Metal discharge pipe D1 from T P valve to tundish 17 Expansion vessel 18 Expansion relief...

Страница 20: ...heating circuit BT01 Temperature sensor heat pump flow BT02 Temperature sensor heat pump return BT06 Temperature sensor heat pump buffer cylinder not for HSBB or TSBB eco BT20 Temperature sensor DHW...

Страница 21: ...X1 7 Connector heating circuit temperature sensor 3 AA01 X1 8 Connector DHW cylinder sensor BT20 AA01 X1 9 Connector source sensor AA01 X1 10 Connector heat source 2 AA01 X1 11 Connector flow cooling...

Страница 22: ...l min 22 6 Max operating temperature heating water C 89 Application limits Max permissible pressure Design Pressure DHW cylinder MPa 0 7 Test pressure DHW cylinder MPa 1 5 Max permissible pressure Des...

Страница 23: ...cordance with national regulations HSBB 200 S GB set Values Expansion vessel volume l 12 Expansion vessel pre charge pressure MPa 0 15 Nominal design flow rate of heating system at A 7 W35 and 7 K m h...

Страница 24: ...land STIEBEL ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 743...