background image

iNSTallaTiON 

 

Specification

www.stiebel-eltron.com 

HSBB 200 S (GB) | 

21

D

00000

800

11

X2.2

X2.3

X2.4

X2.5

X2.6

X2.7

X2.8

X2.9

X2.10

X2.11

X2.12

X2.13

X2.14

X2.15

X1.1

CAN A

X1.19

CAN A

X1.18

CAN B

X1.17

X1.16

X1.15

X1.14

X1.13

X1.12

X1.2

CAN B

X1.3

X1.4

X1.5

X1.6

X1.7

X1.8

X1.9

X1.10

X1.11

X2.1

XD02

L

N

L

1

3

4

22

12

11

21

BT55

<T

AA07

KF22

KF21

KF20

1

3

3

1

3

1

EB01

MFG

X59

L

L

N

N

2

5

N

MA15

BP10

BF01

M

1~

M

1~

PWM

GND

3

2

1

1

4

4

p

OUT
+5V

GND

Hz

T2

T1

+5V

OUT

GND

PT 1000

AA07 

(MFG)

X71

X72

X70

X69

X68

X67

X66

X65

X63

X62

X61

X60

KF20

KF21

KF22

H

L

X64

BT02

BT01

BT06

BT20

MA14

ws (PWM)

br (GND)

L

MA10

M
1~

N

L

M

1~

N

4

3

2

1

4

3

2

1

3

2

1

2

1

4

3

2

1

1

2

3

4

5

6

1

2

3

4

5

6

3

2

1

1

2

1

2

3

4

5

1

2

3

4

5

1

2

1

2

1

2

XD01.1

2

N

2

3

4

L1

1

X27

AA06

4 3 2 1

1 = H

2 = L

3 = 

4 = +12V

L’

2

L

1

+

-

L

H
+
-
L
H

1
2
1
2
1
2
1
2

1
2
1
2
1
2
1
2
1
2

1
2
1
2
3
+

INT

+

INT

1
2
1
2
+

-

L

H
+
-
L
H

L
L
N

PE

L‘

L*
L
N

PE

L
N

PE

L
N

PE

L
N

PE

L
N

PE

L
N

PE

L
N

PE

L
N

PE

L
N

PE

L
N

PE

L
N

PE

N

PE

N

PE

T

+

AA01 (WPM)

XD01.2

XE03

AA01-X1.4

Connector, buffer temperature sensor BT06 

(not for HSBB or TSBB eco)

AA01-X1.5

Connector, flow temperature sensor

AA01-X1.6

Connector, heating circuit temperature sensor 2

AA01-X1.7

Connector, heating circuit temperature sensor 3

AA01-X1.8

Connector, DHW cylinder sensor BT20

AA01-X1.9

Connector, source sensor

AA01-X1.10 Connector, heat source 2
AA01-X1.11 Connector, flow, cooling
AA01-X1.12 Connector, DHW circulation sensor
AA01-X1.13 Connector, remote control FE7
AA01-X1.14 Connector, analogue input 0-10 V
AA01-X2.14 Connector, mixer, heating circuit 2 

(X2.14.1 Mixer OPEN/X2.14.2 Mixer CLOSE)

AA01-X2.15 Connector, mixer, heating circuit 3 

(X2.15.1 Mixer OPEN/X2.15.2 Mixer CLOSE)

AA06-X27

Terminal, programming unit

AA07-X60

Connector, temperature sensor, heat pump flow BT01

AA07-X61

Connector, temperature sensor, heat pump return BT02

AA07-X62

Not assigned – connector, temperature sensor, heat pump return

AA07-X63

Not assigned – connector, temperature sensor, DHW cylinder, 

internal

AA07-X64

Connector, temperature and flow rate, heating circuit, BF01

AA07-X65

Not assigned

AA07-X66

Rast 2.5 connector (heating system pressure) BP01

AA07-X67

Not assigned

AA07-X68

Connector, switching, motor, diverter valve central heating / DHW

AA07-X69

Not assigned

AA07-X70

Connector, switching, pump, heating circuit PWM/1-10V

AA07-X71

Not assigned

AA07-X72

Connector, CAN bus

EB01-X59

Terminal, MFG

Содержание 236916

Страница 1: ...OPERATION AND INSTALLATION Cylinder and hydraulic module HSBB 200 S GB...

Страница 2: ...ring diagram 20 16 4 Details on energy consumption 22 16 5 Data table 22 GUARANTEE ENVIRONMENT AND RECYCLING SPECIAL INFORMATION The appliance may be used by children aged 8 and older and persons with...

Страница 3: ...nt the risk are listed 1 2 2 Symbols type of risk Symbol Type of risk Injury Electrocution Burns burns scalding 1 2 3 Keywords KEYWORD Meaning DANGER Failure to observe this information will result in...

Страница 4: ...nce description The appliance comprises a hydraulic module and an integral DHW cylinder and is equipped with a removable front casing The appli ance is connected hydraulically and electrically to the...

Страница 5: ...If you cannot remedy the fault notify your qualified contractor To facilitate and speed up your request provide the number from the type plate 000000 0000 000000 No 000000 0000 000000 Made in Germany...

Страница 6: ...osses Store and transport the appliance at temperatures be tween 20 C to 60 C Handling If possible transport the appliance to the installation site on the non returnable pallet Alternatively transport...

Страница 7: ...ements or steel pipes Material losses The products of corrosion e g rusty sludge can settle in the heating system components and can result in a lower output or fault shutdowns due to reduced cross se...

Страница 8: ...ine Stainless steel copper and plastic are approved materials 11 4 2 Installing the DHW circulation line if applicable A DHW circulation line with external DHW circulation pump can be fitted to the DH...

Страница 9: ...re position so that the heating circuit and the heat exchanger for DHW heating are filled evenly When power is switched on the 3 way diverter valve automatically switches to heating mode To fill or dr...

Страница 10: ...dance with relevant regulations Before any work on the appliance disconnect all poles from the power supply WARNING Electrocution Only use a permanent connection to the power supply Ensure the applian...

Страница 11: ...rol voltage Appliance function Effect of the electric emergency booster heater Mono energetic operation If the heat pump undershoots the dual mode point the electric emergency booster heater safeguard...

Страница 12: ...xtra low voltage X1 1 CAN A L H L H CAN connection for heat pump and WPE heat pump extension X1 2 CAN B L H L H CAN connection for FET remote control and ISG Internet Service Gateway X1 3 Signal Earth...

Страница 13: ...PE 2nd heat source heating X2 13 L N PE L N PE Cooling X2 14 Mixer OPEN N PE Mixer CLOSE 5 N PE 6 Mixer heating circuit 2 X2 14 1 Mixer OPEN X2 14 2 Mixer CLOSE X2 15 Mixer OPEN N PE Mixer CLOSE 5 N P...

Страница 14: ...doors or air ducts Observe the following minimum clearances 2 5 m above the ground and 1 m to the side of windows and doors Installation f f Remove the cover f f Secure the base with the screw suppli...

Страница 15: ...e observe the rules of the relevant Health Safety at Work Act during commissioning For further details check with your local authorising body 13 1 Checks before commissioning the heat pump manager Mat...

Страница 16: ...Condensation caused by the temperature falling below the dew point can lead to material losses HSBB is there fore exclusively approved for area cooling Adjusting the heat pump manager settings for ar...

Страница 17: ...fication Dimensions and connections Checking replacing the protective anode f f Check the protective anode after the first two years of use and replace if necessary Check that the maximum transition r...

Страница 18: ...80 92 92 177 347 432 517 10 20 177 D0000070858 HSBB 200 S GB b01 Entry electrical cables c01 Cold water inlet Male thread G 1 c06 DHW outlet Diameter mm 22 c10 DHW circulation Male thread G 1 2 c12 Sa...

Страница 19: ...m tundish with continuous fall 11 Equipotential bond 12 Drain valve 13 Cylinder 14 DHW outlet 15 T P valve 16 Metal discharge pipe D1 from T P valve to tundish 17 Expansion vessel 18 Expansion relief...

Страница 20: ...heating circuit BT01 Temperature sensor heat pump flow BT02 Temperature sensor heat pump return BT06 Temperature sensor heat pump buffer cylinder not for HSBB or TSBB eco BT20 Temperature sensor DHW...

Страница 21: ...X1 7 Connector heating circuit temperature sensor 3 AA01 X1 8 Connector DHW cylinder sensor BT20 AA01 X1 9 Connector source sensor AA01 X1 10 Connector heat source 2 AA01 X1 11 Connector flow cooling...

Страница 22: ...l min 22 6 Max operating temperature heating water C 89 Application limits Max permissible pressure Design Pressure DHW cylinder MPa 0 7 Test pressure DHW cylinder MPa 1 5 Max permissible pressure Des...

Страница 23: ...cordance with national regulations HSBB 200 S GB set Values Expansion vessel volume l 12 Expansion vessel pre charge pressure MPa 0 15 Nominal design flow rate of heating system at A 7 W35 and 7 K m h...

Страница 24: ...land STIEBEL ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 743...

Отзывы: