15
04/24999913
Fields of application
Frame brackets K28/B and K29/B with 2 special clamping screws for the side clamping guides.
Can be used up to 500 mm stroke over the whole length of the drive, from 500 mm stroke in the first third of the drive.
Frame bracket K27/B with slide bracket for the bottom clamping guide. Can be used over the whole length of the drive.
The slide bracket has to be fixed at the linear drive with a starting power of 7.5 Newton meter (+/- 0.5 Nm).
Frame bracket K31 with 2 grub screws with points for the side assembling.
Load switch off function
This function is operated using the electronic load switch fitted and does not require a limit switch.
Internal mechanical limit stops provide exact limits without disruptive stroke after-running. When these limit stops are
reached or block a drive in the UP-direction, the electronic load switch off switches all drives off thanks to the increased
engine power. As the motor power is proportional to the shear and tensile forces this switch off takes place at exactly
defined forces.
Caution
:
Destruction of the motor. Never operate the linear drive without load switch off.
Operate the load switch in general with 24 V protective extra low voltage.
Linear drive M3/...-500N:250N/LA/AC