40
Inversion Switch
ß
The inversion switch is a mercury switch
(A)
which is actu-
ated in case of an inclination of the boat in any direction
over 70°.
Via the main circuit relay the engine is shut down.
For safe
guarding reasons the inversion switch is to be checked
every 50 hrs or 6 months.
(See service- and maintenance
chart page 64).
ATTENTION:
After such an event, this temporarily
stored operating condition is to be
cancelled from the engine management
system by ignition “OFF” = “Reset”.
Without “Reset”, a new start of the engine
is not possible.
q
Interrupt crankshaft housing ventilation
“
During an activation of the mercury switch inversion, the by-
pass valve
(B)
for crankshaft housing ventilation is closed
too.
This avoids a possible oil outlet via suction through the air
filter.
Instrument Panel
The engines are supplied with the standard instrument panel.
The respective customer may use a self-adapted STEYR MOTORS instrument panel or one which corresponds to
his own ideas and requirements.
ATTENTION:
For not approved alterations which lead to engine failure, no liability can be undertaken.
q
Dry Operation
After a dry operation of the engine (without raw water cooling), check the impeller of the raw water pump for dama-
ges. Replace if necessary. Grease the impeller, use grease from special impeller kit Z011753/2.
BUKH STEYR MOTORS SOLAS
11
06012
A
12
06010
B
Содержание MO114K33
Страница 2: ......
Страница 14: ...14 ...
Страница 46: ...46 fullload speedrange 100 90 80 70 60 50 40 30 B C D RPM A OUTPUT POWER ...
Страница 62: ...62 fullload speedrange 100 90 80 70 60 50 40 30 B C D RPM A OUTPUT POWER ...
Страница 64: ...64 ...
Страница 90: ...90 ...
Страница 106: ...106 ...
Страница 118: ...118 ...