st
eut
e T
echnol
ogies GmbH & Co. K
G
Brück
ens
tr
aße 91, 32584 Löhne, Germany
, www
.s
teut
e.c
om
//
RF Rx SW868/SW915/SW917/SW922-4W 24VAC/DC
5 / 28
Montage- und Anschlussanleitung / Funkempfänger
Mounting and wiring instructions / Wireless receiver
Instructions de montage et de câblage / Récepteur sans fil
Istruzioni di montaggio e collegamento / Ricevitore wireless
Instruções de montagem e instalação / Receptor sem fio
Инструкция по монтажу и подключению / Радио-приемник
English
Operation
mode
LED 1
LED MD Function
Standard
flashes
fast
flashes
fast
Relay energised by actua-
tion, relay and switch func-
tions are reset.
Relay functions
Standard,
inverse output
flashes
fast
on
Upon actuation: relay is de-
energised. Inverse output
signal.
Relay energised on
flashes
fast
Relay energised by providing
operating voltage.
Relay energised,
inverse output
on
on
Relay energised by providing
operating voltage, inverse
output signal.
Switch functions
Logic function
flashes
slowly
on
The logic functions OR, AND
or Xor are selectable.
Latching
function
on
flashes
slowly
Latching function/
Impulse function
Wiping
function
flashes
slowly
flashes
slowly
Wiping function. After pre-
set time: contact de-ener-
gises automatically.
Additional
functions
Battery
monitoring
off (LED
3 flash-
es)
flashes
slowly
Relay K3 indicates under-
voltage of the taught-in and
battery-powered switches/
transmitters.
Status
monitoring
off (LED
4 flash-
es)
flashes
slowly
Relay K4 indicates status
error; activates function only
in combination »switch with
status signal«.
Detected errors are additionally indicated by flashing of the
assigned channel LED.
Notice
If only one or both additional functions are activated, no further wire-
less transmitter can be taught in.
Operation mode logic function
- Select logic function. -> LED MD flashes fast.
- Set logic function push-button S2. -> Observe LED display (see table).
- When the desired LED combination is displayed, press push-button
S1 for 1 s.
Safety
Do not use the device in connection with other devices whose direct or
indirect purpose is to ensure life or health, or whose operation may
pose a threat to humans, animals or material assets.
N.B.
The electrical connection may only be carried out by authorised per-
sonnel. Subject to technical modifications. The described products
were developed in order to assume safety functions as part of an entire
plant or machine. It is the responsibility of the manufacturer of a plant
or machine to guarantee the correct general function. steute does not
assume any liability for recommendations made or implied by this de-
scription. New claims for guarantee, warranty or liability cannot be de-
rived from this document beyond the general terms and conditions
of delivery.
Variants
Mat. No.
Variant
1244986
RF Rx SW868 4W 12 VDC Status monitoring
1319798
RF Rx SW868 4W Battery/Status monitoring
In these variants the status monitoring or status and battery monitor-
ing functions are always activated (factory setting of status monitoring
to 10 s).
Start-up
Requirements:
- Device is mounted on DIN rail.
- Conductors for 24 VAC/DC voltage supply are connected.
- A maximum of 40 switches can be taught in parallelly.
- The LEDs show the operating states. When the operating voltage has
been provided to the receiver and no switch has been taught in, the
orange LED 1 flashes. When the operating voltage has been provided
to the receiver and switches have already been taught in, the orange
LED 1 is off.
Select operation mode
There are nine different operation modes (see table). They may be se-
lected only after switch-on of the receiver. Operation modes may be
selected during configuration mode only. The relay functions can be
combined with the switching functions.
1. To start the receiver in configuration mode and select an operation
mode: press push-button S1 and keep it pressed. Switch on the sup-
ply voltage. Once the LED MD is blinking: release push-button S1.
Operation mode changes consecutively every 5 s automatically or by
pressing push-button S2. For display of the LEDs: see table.
2. If the desired operation mode is displayed, press the push-button S1
for 1 s. The desired operation mode is now activated. If S1 is not ac-
tuated within 5 s, it is switched to a different operation mode.