11
MANUAL SETTINGS ADJUSTMENT
The sensor range is the range an object can be away from the sensor in order to activate
the faucet. The sensor is factory preset. If necessary, it can be adjusted as follows:
1
Disconnect the power supply, battery or transformer, from the sensor.
2
Make a short circuit between the (+) and the (-) of the sensor.
You can use a screw driver or another conductor material to make this
short circuit. Alternatively, after disconnecting the power supply, activate
the sensor three or four times.Do not make a short circuit on the power
supply or on the sensor when the power supply is connected to the
sensor.
3
Reconnect the power supply to the sensor.
4
To go into the adjusting mode, put your hand in front of the sensor at a
distance of 2”(5cm) to 4”(10cm) within 5 seconds after the reconnection
of the power supply.
NOTE: If you will not put your hand in front of the sensor after connecting the power
supply, the sensor will not enter into adjusting mode and the previous setting will
return.
5
When the sensor goes into the adjusting mode and your hand is in front
of the sensor, a slow flashing of the red light at the front of the sensor will
occur.
6
Keep your hand at the front of the sensor until the slow flashing changes
into quick flashing. At this point, move your hand to the required distance
from the sensor and wait until the red light will stop flashing.
7
When the red light has turned off, the sensor has been adjusted to the
required distance.
8
Check the distance you have set and if it is not satisfactory, repeat steps
1-6.