lIMITED warraNTy

Y. Stern Engineering Ltd. warrants that its electronic products will be free of defects in 

material and workmanship during normal use for two years from the date the product is 

purchased. 

If a defect is found in normal use, Y. Stern Engineering Ltd. will, at its discretion, repair, 

provide a replacement part or product, or make appropriate adjustments. Damage 

caused by accident, misuse, or abuse is not covered by this warranty. Improper care 

and cleaning will void the warranty. proof of purchase (original sales receipt) must be 

provided to Stern Engineering Ltd. with all warranty claims. 

Stern Engineering Ltd is not responsible for labor charges, installation, or other incidental 

or consequential costs other than those noted above. In no event shall the liability of 

Stern Engineering Ltd. exceed the purchase price of the product. 

If you believe that you have a warranty claim, contact your Stern Distributor, Dealer or 

plumbing Contractor. please be sure to provide all pertinent information regarding your 

claim, including a complete description of the problem, the product, model number, 

the date the product was purchased, from whom the product was purchased and the 

installation date. Also include your original invoice. 

Y. STERN ENGINEERING AND/OR SELLER DISCLAIM ANY LIABILITY FOR SpECIAL, 

INCIDENTAL OR CONSEQUENTIAL DAMAGES. This warranty excludes product damage due 

to installation error, incorrect maintenance, wear and tear, battery,  product abuse, or 

product misuse, whether performed by a contractor, service company, or the consumer. 

This warranty does not cover product damage caused by the following: 
- Incorrect installation. 
- inversions of supply pipes.
- pressures or temperatures exceeding recommended limits.
- Improper manipulation, tampering, bad or lapsed maintenance. 
- Foreign bodies, dirt or scale introduced by the water supply or soap tank.
- Use of the soap outside of viscosity specifications.
- Alteration of the original soap/foam dispenser components (including pipes).

TrouBlEshooTINg

* “Security Mode”: If the sensor is covered for more than 90 sec. the faucet will automatically shut off water flow. 

To return to normal operation remove any blockage.
** In this case, the water flow will stop anyway after 90 seconds because of the security time.

soluTIoN

causE

 INDIcaTor

 ProBlEM

Replace battery

Low battery.

1. Sensor flashes 

continuously 

when user’s 

hands are within 

the sensor’s 

range.

No water 

coming out 

of the faucet:

Increase the range

1. Range is too short.

2. LED in the 

sensor does not 

flash once when 

user’s hands   

are within the 

sensor’s range.

Decrease the range

2. Range is too long.

The battery must be replaced. 

3. Battery is completely used up 
4. Unit is in “Security Mode”*

Eliminate cause of reflection. 

5. Sensor is picking up reflections from the 

washbasin or another object.

Connect the electronic unit 

connectors to the solenoid.

1. Connectors between the electronic unit and 

solenoid are disconnected.

3. LED in the 

sensor flashes 

once when 

user’s hands 

are within the 

sensor’s range.

Unscrew solenoid, pull out the 

plunger and the spring from 

the solenoid and clean them. 

Use scale remover material if 

needed. When replacing the 

plunger, please make sure that 

the spring is in vertical position. 

2. Debris or scale in solenoid.

Clean the orifice or replace 

diaphragm. 

3. The central orifice in the diaphragm is plugged 

or the diaphragm is torn

Reduce the supply water 

pressure.

4. The water supply pressure is higher than 8 bar.

Shut off water supply and 

unscrew one of the flexible 

pipes in order to reduce the 

pressure that blocks the 

product.

5. The water supply pressure is under 8 bars and 

yet the pressure in the faucet’s body is higher. 

This situation could be caused by a sudden 

increase in the water supply pressure that the 

back check prevents from dropping, even after 

water supply pressure drops under 8 bars.

Clean the orifice or replace 

diaphragm. 

Debris or scale in diaphragm

1. Sensor flashes 

once when 

user’s hands 

are within the 

sensor’s range. 

Water flow 

from spout 

does not 

stop:

Clean or eliminate case of 

interference.

1. Sensor is dirty or covered.**

2. LED in the 

sensor does not 

flash once when 

user’s hands 

are within the 

sensor’s range.

Decrease the range or eliminate 

cause of reflection. 

2. Sensor is picking up reflections from the 

washbasin or another object.

Remove, clean, re-install

Filter or aerator is clogged

Water flow 

diminished

Содержание DOLPHIN 1000 F Series

Страница 1: ...I n sta l l at i o n a n d m a i n t e n a n c e g u i d e ELECTRONIC LAVATORY FAUCET DOLPHIN f DOLPHIN 1000 f...

Страница 2: ...optional remote control Minimum sensor range 80 mm 3 15 Maximum sensor range 300mm 11 81 Security time 90 seconds can be reduced with optional remote control Hot water temperature Max 70 C 1 TECHNICAL...

Страница 3: ...x Filter 2 x Filters 1 x Filter adapter 1 x solenoid and housing 1 x Allen Key 1 x Faucet and attachments 1 x Faucet and attachments b VERSIONS e VERSIONS 9V battery box 9V Switching transformer b VE...

Страница 4: ...r supply lines thoroughly before installing the faucet Do not allow dirt Teflon tape or metal particles to enter the faucet Shut off water supply Important All plumbing is to be installed in accordanc...

Страница 5: ...upply inlet to the adapter at the solenoid valve housing 3 Turn on the central water supply and the shut off valve angle valve and check for leaks 1 INLET VERSION 2 INLETS VERSION Step 4 Connecting th...

Страница 6: ...the LED in the sensor eye is perceived Then press to increase the one level and to reduce it every push will increase or decrease one level Note Once you have changed the detection range with the rem...

Страница 7: ...until a quick flashing of the LED of the sensor eye is perceived Then press to increase the security time and to reduce it 24 hour hygiene flush This model includes a 24 hours hygiene flush which is d...

Страница 8: ...er flow has decreased this can be because the filter is clogged The filter can be cleaned as follows 1 Shut off the water shut off valve angle valve 2 Remove the filter located between the solenoid va...

Страница 9: ...omatically shut off water flow To return to normal operation remove any blockage In this case the water flow will stop anyway after 90 seconds because of the security time SOLUTION CAUSE INDICATOR PRO...

Страница 10: ...07 18 015270170 B 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com tech sternfaucets com...