sParE ParTs lIsT  

SEALS & SCREWS KIT DOLphIN FB/FE 

07210099

SEALS & SCREWS KIT DOLphIN 1000FB/1000FE

07210100

10-pACK SENSOR KIT DOLphIN FB/FE

07220430

10-pACK SENSOR KIT DOLphIN 1000FB/1000FE

07220362

10-pACK SOLENOID VALVE KIT

07232000

INSERT KIT DOLphIN FB/FE

07240006

INSERT KIT DOLphIN 1000FB/1000FE

07240028

8-pACK SOLENOID hOUSING KIT DOLphIN FB/FE

07221119

SpOUT KIT DOLphIN FB/FE

07271035

SpOUT KIT DOLphIN 1000FB/1000FE

07271016

NIppLE KIT DOLphIN 1000FB/1000FE

07246007

hANDLE KIT DOLphIN 1000FB/1000FE

07260013

MIxER hANDLE KIT DOLphIN 1000FB/1000FE

07260012

BATTERY BOx FOR 9V BATTERY

06530080

12-pACK 9V TRANSFORMER (EU pLUG) 

06540002

REMOTE CONTROL 13B (OpTIONAL)

07100005

SOAp & WATER REMOTE CONTROL (OpTIONAL)

07100014

MaINTENaNcE

FILTER CLEANING INSTRUCTIONS
This faucet is provided with one stainless steel filter preventing foreign particles to enter 

the lines. It is recommended to clean the filter every six (6) months. If the water flow has 

decreased, this can be because the filter is clogged. The filter can be cleaned as follows:

1. Shut-off the water shut off valve (angle valve).
2. Remove the filter located between the solenoid valve housing and the inlet adapter \ 

shut off valve.
3. Wash the filter under running water.
4. Reassemble the parts. 
5. Make sure that there is no water leakage.

CARE AND CLEANING OF ChROME AND SpECIAL FINIShES
DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or the like. 

Use of any prohibited cleaning or maintenance products or substances could damage the 

surface of the faucet. For surface cleaning of faucet use ONLY soap and water, then wipe dry 

with clean cloth or towel. When cleaning bathroom tile, the faucets should be protected 

from any splattering of harsh cleansers.

SOLENOID VALVE SERVICING
The solenoid valve diaphragm requires  periodical cleaning every six (6) months.    Remove 

the diaphragm from the solenoid valve and examine it for dirt. in case it is dirty or clogged, 

wash it under running water and reassemble it.

Do not attempt to dismantle the solenoid valve if you are unfamiliar with electronic 

solenoid valves.

Содержание DOLPHIN 1000 F Series

Страница 1: ...I n sta l l at i o n a n d m a i n t e n a n c e g u i d e ELECTRONIC LAVATORY FAUCET DOLPHIN f DOLPHIN 1000 f...

Страница 2: ...optional remote control Minimum sensor range 80 mm 3 15 Maximum sensor range 300mm 11 81 Security time 90 seconds can be reduced with optional remote control Hot water temperature Max 70 C 1 TECHNICAL...

Страница 3: ...x Filter 2 x Filters 1 x Filter adapter 1 x solenoid and housing 1 x Allen Key 1 x Faucet and attachments 1 x Faucet and attachments b VERSIONS e VERSIONS 9V battery box 9V Switching transformer b VE...

Страница 4: ...r supply lines thoroughly before installing the faucet Do not allow dirt Teflon tape or metal particles to enter the faucet Shut off water supply Important All plumbing is to be installed in accordanc...

Страница 5: ...upply inlet to the adapter at the solenoid valve housing 3 Turn on the central water supply and the shut off valve angle valve and check for leaks 1 INLET VERSION 2 INLETS VERSION Step 4 Connecting th...

Страница 6: ...the LED in the sensor eye is perceived Then press to increase the one level and to reduce it every push will increase or decrease one level Note Once you have changed the detection range with the rem...

Страница 7: ...until a quick flashing of the LED of the sensor eye is perceived Then press to increase the security time and to reduce it 24 hour hygiene flush This model includes a 24 hours hygiene flush which is d...

Страница 8: ...er flow has decreased this can be because the filter is clogged The filter can be cleaned as follows 1 Shut off the water shut off valve angle valve 2 Remove the filter located between the solenoid va...

Страница 9: ...omatically shut off water flow To return to normal operation remove any blockage In this case the water flow will stop anyway after 90 seconds because of the security time SOLUTION CAUSE INDICATOR PRO...

Страница 10: ...07 18 015270170 B 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com tech sternfaucets com...

Отзывы: