12
13
sParE ParTs lIsT
SEALS & SCREWS KIT DOLphIN FB/FE
07210099
SEALS & SCREWS KIT DOLphIN 1000FB/1000FE
07210100
10-pACK SENSOR KIT DOLphIN FB/FE
07220430
10-pACK SENSOR KIT DOLphIN 1000FB/1000FE
07220362
10-pACK SOLENOID VALVE KIT
07232000
INSERT KIT DOLphIN FB/FE
07240006
INSERT KIT DOLphIN 1000FB/1000FE
07240028
8-pACK SOLENOID hOUSING KIT DOLphIN FB/FE
07221119
SpOUT KIT DOLphIN FB/FE
07271035
SpOUT KIT DOLphIN 1000FB/1000FE
07271016
NIppLE KIT DOLphIN 1000FB/1000FE
07246007
hANDLE KIT DOLphIN 1000FB/1000FE
07260013
MIxER hANDLE KIT DOLphIN 1000FB/1000FE
07260012
BATTERY BOx FOR 9V BATTERY
06530080
12-pACK 9V TRANSFORMER (EU pLUG)
06540002
REMOTE CONTROL 13B (OpTIONAL)
07100005
SOAp & WATER REMOTE CONTROL (OpTIONAL)
07100014
MaINTENaNcE
FILTER CLEANING INSTRUCTIONS
This faucet is provided with one stainless steel filter preventing foreign particles to enter
the lines. It is recommended to clean the filter every six (6) months. If the water flow has
decreased, this can be because the filter is clogged. The filter can be cleaned as follows:
1. Shut-off the water shut off valve (angle valve).
2. Remove the filter located between the solenoid valve housing and the inlet adapter \
shut off valve.
3. Wash the filter under running water.
4. Reassemble the parts.
5. Make sure that there is no water leakage.
CARE AND CLEANING OF ChROME AND SpECIAL FINIShES
DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or the like.
Use of any prohibited cleaning or maintenance products or substances could damage the
surface of the faucet. For surface cleaning of faucet use ONLY soap and water, then wipe dry
with clean cloth or towel. When cleaning bathroom tile, the faucets should be protected
from any splattering of harsh cleansers.
SOLENOID VALVE SERVICING
The solenoid valve diaphragm requires periodical cleaning every six (6) months. Remove
the diaphragm from the solenoid valve and examine it for dirt. in case it is dirty or clogged,
wash it under running water and reassemble it.
Do not attempt to dismantle the solenoid valve if you are unfamiliar with electronic
solenoid valves.