SETTINGS ADJUSTMENT

DETECTION RANGE

: This faucet was supplied with a self adjusting 

sensor. The ideal detection range for the specific location will be set 

automatically. Only if necessary, use the remote control to adjust the 

sensor range as follows:
Press the 

RANGE

 button. Wait until a quick flashing of the red light in 

the sensor eye is perceived. Then, press 

+

 to increase the range and 

 

to reduce it. Every push will increase or decrease one level. 

NOTE:

 Once you have changed the detection range with the remote control, 

the distance will be remembered by the sensor, even if the power source is 

disconnected. To get back to the self adjustment mode, use the

 ADJ

 button only.

ENTRANCE TO THE SELF ADJUSTMENT MODE: 

 Check that no objects 

are in front of the sensor. Press the 

ADJ

 button. Once a quick flashing 

of the red light of the sensor eye is perceived, remove your hand 

holding the remote control and move away from the sensor area. The 

ideal sensor range for the specific location will be set automatically. 

Once the self adjustment has taken place, the solenoid valve will be 

opened and closed for 1 second as an indication that the ideal sensor 

range was set and the product is ready for use. 

SECURITY TIME:

 The Security time, prevents continuous running 

of water due to reflections or vandalism. By default, if the sensor 

is covered for more than 90 seconds the water flow will shut 

automatically. To resume regular operation any obstruction must be 

removed.

Press the 

SEC

 button. Wait until a quick flashing of the red light in the 

sensor eye is perceived. Then, press 

+

 to increase the security time 

and 

 to reduce it.

DELAY IN TIME

: It is recommended to change the delay in time for 

flush valves for urinals or toilets only. If required, the delay in time can 

also be modified in faucets as follows:
Press the IN button. Wait until a quick flashing of the red light in the 

sensor eye is perceived. Then, press + to increase the delay in time 

and – to reduce it.

Содержание 280300

Страница 1: ...1 INSTALLATION AND MAINTENANCE GUIDE BEHIND MIRROR TOUCH FREE FAUCET ...

Страница 2: ...rovided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular purpose or non infringement Stern Engineering Ltd assumes no responsibility for errors or omissions in the information presented in this document In no event shall Stern Engineering Ltd be liable for any special incidental indirect o...

Страница 3: ... pressure 0 5 8 0 bar 7 116 PSI With water pressure of more than 8 bars use a pressure reducing valve Sensor range Self adjusting sensor Adjustable with remote control Minimum sensor range 80 mm Maximum sensor range 300 mm Security time 90 seconds Can be reduced with the remote control Hot water temperature Max 70ºC BTM E 280300 ...

Страница 4: ...ze yourself with the part names and confirm that the parts are included 2 screws up to 5mm not supplied 1 x Plate with faucet spout sensor and solenoid valve TRANSFORMER IP 67 BLACK BATTERY BOX FOR 6X1 5V AA ALKALINE BATTERIES ...

Страница 5: ...n tape or metal particles to enter the faucet Shut off the water supply IMPORTANT All plumbing is to be installed in accordance with applicable codes and regulations Pay attention that the dimensions of the mirror compartment fits the dimensions of the faucet plate WARNING 1 To avoid reflection problems keep a distance of more than 300 mm between the sink and the spout 2 This faucet model with an ...

Страница 6: ... bottom of the mirror compartment for the faucet sensor and spout both The recommended hole size should be 40x60 mm 60 mm 40 mm STEP 2 INSTALLING THE FAUCET 1 Remove the protective sticker covering the sensor 2 Place the faucet assembly inside the mirror compartment with the spout sticking out of the hole ...

Страница 7: ...5 FAUCET INSTALLATION 3 Secure the plate to the wall with 2 screws not supplied 4 Connect the flexible pipe to the main water supply Turn on the central water supply and check for leaks ...

Страница 8: ...e wall in the mirror compartment and connect the battery connector For transformer versions Plug the transformer into the electricity socket and make sure the transformer connector is connected to the sensor 3 Wait about 10 seconds before you put your hands within the sensor range 10 SECONDS If the automatically adjusted sensor range is not satisfactory to your purposes please refer to the section...

Страница 9: ...on you want to adjust by pressing once on one of the function buttons After pressing once on a specific function button a quick flashing of the red light at the front of the sensor will occur At this stage you can change the setting by pressing the or the buttons every push will increase or decrease one level After finishing the adjustment turn the water supply back on DETECTION RANGE DELAY OUT TI...

Страница 10: ...ding the remote control and move away from the sensor area The ideal sensor range for the specific location will be set automatically Once the self adjustment has taken place the solenoid valve will be opened and closed for 1 second as an indication that the ideal sensor range was set and the product is ready for use SECURITY TIME The Security time prevents continuous running of water due to refle...

Страница 11: ... To activate the hygiene flush press the clock button Wait until a quick flashing of the red light in the sensor eye is perceived Then press to activate the hygiene flush or to deactivate it TEMPORARY OFF FUNCTION This function is ideal to perform any kind of activity in front of the sensor without operating the system for example cleaning The faucet will remain shut for 1 minute when this button ...

Страница 12: ...es NOTE Do not mix used batteries with new ones NEW BATTERY NEW BATTERY NEW BATTERY NEW BATTERY NEW BATTERY NEW BATTERY 4 Close the box NEW BATTERY NEW BATTERY NEW BATTERY NEW BATTERY NEW BATTERY NEW BATTERY When the battery weakens the red indicator light will blink at a constant rate when the user s hands are within the sensor range The battery must be replaced within two weeks IMPORTANT Spent b...

Страница 13: ...LVE SERVICING The solenoid valve diaphragm requires periodical cleaning every six 6 month Remove the diaphragm from the solenoid valve and examine it for dirt in case it is dirty or clogged wash it under running water and reassemble it Do not attempt to dismantle the solenoid valve if you are unfamiliar with electronic solenoid valves CARE AND CLEANING OF CHROME AND SPECIAL FINISHES DO NOT use ste...

Страница 14: ...ntial costs other than those noted above In no event shall the liability of Stern Engineering Ltd exceed the purchase price of the shower valve or control If you believe that you have a warranty claim contact your Stern Distributor Dealer or Plumbing Contractor Please be sure to provide all pertinent information regarding your claim including a complete description of the problem the product model...

Страница 15: ...d 3 Red light in the sensor flashes once when user s hands are within the sensor s range Clean the orifice or replace diaphragm 2 The central orifice in the diaphragm is plugged or the diaphragm is torn Reduce the supply water pressure or install a pressure reducer valve 3 The water supply pressure is higher than 8 bar 116 PSI Shut off water supply and un screw one of the flexible pipes in order t...