Sterling Power Products AB12160 Скачать руководство пользователя страница 8

fa

n

fa

n

engine

alternator

ENSURE ALL NEGS ARE COMMON

DOMESTIC BATTERY SYSTEM

3

5

 a

m

p

 f

u

s

e

+

+

ENGINE STARTER

BATTERY

fuse

7

R

ig

h

t H

a

n

d

 S

id

e

L

e

ft 

H

a

n

d

 S

id

e

1

   

2

   

3

   

4

ON

1  

 2

O

N

1

  

 2

O

N

WHAT CABLE TO USE IN sq mm

A charger or inverter up to        cable run distance 0-1.5 mtr           1.5 - 4 mtr

          0-25 amps                                 6 mm sq                                      10 mm sq
        25-45 amps                               16 mm sq                                      25 mm sq
        45-85 amps                               25 mm sq                                      35 mm sq   
      85-125 amps                               35 mm sq                                      50 mm sq
   125- 180 amps                               50 mm sq                                      70 mm sq
    180-330 amps                               70 mm sq                                      90 mm sq 

Please note that if there is a problem obtaining for example 90 sq mm cable, 
simply use 2 x 50 sq mm or 3 x 35 sq mm. The cable is simply copper, and 
all you require is the copper. It does not matter if it is one cable or 10 cables 
as long as the cross-section adds up. Performance of any product can be 
improved by thicker cable, so if in doubt round up.

fa

n

fa

n

engine

alternator

ENSURE ALL NEGS ARE COMMON

DOMESTIC BATTERY SYSTEM

200 amp shunt

engine battery current

( optional remote kit )

Battery

temperature 

sensor

cable

( supplied )

Remote control

and information panel

( optional remote kit )

Starter motor

solonoid

3

5

 a

m

p

 f

u

s

e

+

+

+

Engine 

starter

key

ENGINE STARTER

BATTERY

light

light

CE

on/off

on/off

beep

beep

1
2
3
4

2

2

4

4

3

3

1

1

Power Management

with

AMP Hr Counter

Sterling power products

Amp

hr

Amps                              Volts

14.35 v  m Pos 4
37amps 435 a/hrs

Sterling power products

CE

on/off

alarm

light

temp

System

Default

Low voltage warning

System Disengaged

System Trip

System Within Limits

Screen

Help

Bat 14.4v Timer
Alt 15.4v 134m

set up

volts

temp sensor

temp sensor

fuse

1

2

3

4

5

Alternator

temperature 

sensor

cable

( supplied )

8

Advanced Alternator Regulator

R

ig

h

t H

a

n

d

 S

id

e

L

e

ft 

H

a

n

d

 S

id

e

10

14

1

   

2

   

3

   

4

This unit comes set up for the standard 
Sterling 200 amp shunt (1mV = 1 amp). 
However it can be reprogrammed to 
accept a 500 amp shunt (0.1mV = 1 
amp).

 

13

a a

b

a

b

b

ON

1  

 2

O

N

1

  

 2

Low  alternator regulator  voltage 
adjustment:

 This  should only be used 

if the alternator’s standard voltage 
regulator is set below 13.8

 

volts. Only 

if this is the case, switch switch 1 on. 
Switch 2 is not in use.

O

N

15

17

200 amp shunt

alternator current

( optional remote kit )

a

b

9

F

ULL

 S

YSTEM

 W

IRING

(

INCLUDING

 

OPTIONAL

 

REMOTE

 

KIT

 - 

)

KIT

 

PARTS

 

IN

 

GREEN

B

ASIC

 S

YSTEM

 W

IRING

8

9

12

11

6

OPEN
LEAD ACID

GEL-
BATTERIES
(EXIDE SPECIFICATION)

SEALED LEAD
ACID & AGM

GEL & AGM
(US SPECIFICATION)

O

N

1

  

 2

1

  

 2

O

N

1

  

 2

O

N

1

  

 2

LED

COLOUR

MAX. CHARGING

VOLTAGE

ABSORBTION

TIME

FLOATING

VOLTAGE

YELLOW

GREEN

RED

GREEN FLASHING

FOR 5 SEC.

14.8V / 20°C

14.4V / 20°C

14.4V / 20°C

14.2V / 20°C

13.65V / 20°C

13.8V / 20°C

13.65V / 20°C

13.5V / 20°C

1 - 10 HRS.

12 - 24 HRS.

4 - 8 HRS.

4 - 10 HRS.

O

N

6

OPEN
LEAD ACID

GEL-
BATTERIES
(EXIDE SPECIFICATION)

SEALED LEAD
ACID & AGM

GEL & AGM
(US SPECIFICATION)

O

N

1

  

 2

1

  

 2

O

N

1

  

 2

O

N

1

  

 2

LED

COLOUR

MAX. CHARGING

VOLTAGE

ABSORBTION

TIME

FLOATING

VOLTAGE

YELLOW

GREEN

RED

GREEN FLASHING

FOR 5 SEC.

14.8V / 20°C

14.4V / 20°C

14.4V / 20°C

14.2V / 20°C

13.65V / 20°C

13.8V / 20°C

13.65V / 20°C

13.5V / 20°C

1 - 10 HRS.

12 - 24 HRS.

4 - 8 HRS.

4 - 10 HRS.

O

N

7

Содержание AB12160

Страница 1: ...technology 4 DUR A L B A L T I E G I D D E S C I I G M N ANYD ProDigital RoHS compliant www sterling power com English Deutsch Français Español Italiano Nederlands Svenska Alternator to Battery Chargers and Remote Control STERLING POWER PRODUCTS ...

Страница 2: ...f water and soap nearby in case battery acid comes in 4step charging of the domestic battery including temperature contact with skin clothes or eyes Wear complete eye compensation protection and protective clothing Avoid touching the eyes No interference with engine electronics Because the system while working with a battery does not increase the voltage of the starter battery there is no risk of ...

Страница 3: ...ires on the other end to the small terminals marked battery temp Be careful not to Sealed lead acid batteries and AGM batteries These batteries damage or alter the temperature sensor in any way The system are also charged at an absorption voltage of 14 4V however with will then sense the battery temperature and change the output a shorter absorption time voltage in accordance with the recommended ...

Страница 4: ... the bulk charge phase A flashing green LED indicates that the unit is in pause mode to provide additional charge capacity for the starter battery LED 2 TIME CONTROL ON yellow This LED indicates that the voltage is approaching or has reached the absorption level It will come on only in addition to LED 1 LED 3 FLOAT POWERPACK green This LED indicates that the absorption charge has been finished and...

Страница 5: ...tandard lead acid and the time period between and What you can see here is that by domestic battery is 3 x 100 amp hr standard lead acid The engine switching off the amplifier to help the engine battery getting more battery was discharged to 11 volts about 10 engine starts and charge the engine battery voltage curve increases during that the domestic bank to about 11 volts will no longer run an in...

Страница 6: ...remote control will show 2 Top Mounting without Frame the software release of the charger and the remote control unit In case you are experiencing a problem with your alternator to Slide the small left and right hand covers A off the front panel battery charger please take a note of these numbers before you which will expose the screws Unscrew and remove the frame contact us B Use the inside of th...

Страница 7: ...in per cent Pressing this key a working correctly third time will show the software release of the remote control R and the charger C as well as the system voltage Special Functions 4 Key temp Auto Pause Function Pressing this key once will display the temperature of the The alternator to battery charger is programmed in such a way alternator ALT and the temperature of the battery BAT In that the ...

Страница 8: ...taining for example 90 sq mm cable simply use 2 x 50 sq mm or 3 x 35 sq mm The cable is simply copper and all you require is the copper It does not matter if it is one cable or 10 cables as long as the cross section adds up Performance of any product can be improved by thicker cable so if in doubt round up BASIC SYSTEM WIRING 8 6 OPEN LEAD ACID GEL BATTERIES EXIDE SPECIFICATION SEALED LEAD ACID AG...

Страница 9: ...ed 8 Advanced Alternator Regulator Right Hand Side Left Hand Side 10 14 1 2 3 4 This unit comes set up for the standard Sterling 200 amp shunt 1mV 1 amp However it can be reprogrammed to accept a 500 amp shunt 0 1mV 1 amp 13 a a b a b b ON 1 2 ON 1 2 Low alternator regulator voltage adjustment This should only be used if the alternator s standard voltage regulator is set below 13 8 volts Only if t...

Страница 10: ...rbeitet explosiver Gase zu vermeiden stellen Sie sicher dass die Batterien mindestens 4 Stunden vor Beginn der Das Lichtmaschinen Batterie Ladegerät maximiert die Installationsarbeiten nicht geladen wurden Ausgangsleistung der Lichtmaschine und zieht dabei deren Ausgangsspannung auf ca 13V herunter Diese bei hohem Ausgangsstrom anliegende niedrige Spannung wird anschließend im Gerät auf eine höher...

Страница 11: ...t sich dann zwar starten aber die Lichtmaschine Kabelstärke die mindestens für einen doppelt so hohen Strom erzeugt unter Umständen keine Spannung Zur Lösung des geeignet sind als eigentlich erforderlich Wenn Sie z B eine 70A Problems nutzen Sie die mit starter solenoid feed bezeichnete Lichtmaschine haben dann verwenden Sie mindestens ein 140A Geräteklemme und verbinden diese mit der Anlasser Kle...

Страница 12: ...nte Software des auf eine defekte Lichtmaschine oder Batterie Gerätes berechnet automatisch die optimale Ausgleichsladezeit zwischen 1 und 24 Stunden LED 5 HIGH BAT V TEMP FL rot Wenn die Batterien vollständig geladen sind wird die Spannung Eine konstant rot brennende LED 5 bedeutet dass das Gerät abgesenkt und es liegt eine konstante Erhaltungsladespannung sich aufgrund einer Überspannung an der ...

Страница 13: ...es Fehler nach dem Neustart immer noch vorhanden ist setzen Sie sich bitte mit dem Sterling Kundendienst in Verbindung STARTER BATTERY SHUNT optional Anschluss für den Starterbatterie Messwiderstand Bestandteil LED 10 UNIT FAILURE LHS rot des Fernbedienungspaketes Diese LED zeigt einen Fehler auf der linken Seite der integrierten Trenndiode an Starten Sie das Gerät neu Wenn der Fehler nach dem Neu...

Страница 14: ...n Sie das Gerät mit nicht neben Leitungen die hohe Ströme leiten Durch die Nähe geeigneten Schrauben kann es zu Störungen in der Datenübertragung kommen Es handelt sich um eine reine Datenverbindung die mit sehr geringen Spannungen arbeitet 2 Montage als Einbaugerät Wir empfehlen Ihnen dringend dieses Kabel nicht zu kürzen Im Entfernen Sie die Aufbaublende B vom Gerät durch Abziehen Falle einer Au...

Страница 15: ...ner Standardanzeige diese Taste nochmals die Funktion des Ladegerätes nicht aus Bitte überprüfen Sie die gedrückt so erscheint im Display die nach dem letzten Ausgangsspannung Ihrer Lichtmaschine und Ihre Einschalten des Gerätes verstrichene Zeit ON sowie die Kabelverbindungen kumulierte Boost Zeit des Gerätes BOOST 4 System within limits grün 2 Taste ê Alle Systemparameter und funktionen sind nor...

Страница 16: ... after return of the product to the company Sterling Power Products Ltd will ship the repaired or replaced product back to the customer This warranty is in lieu of all others expressed or implied Vordringliches Ziel unseres Unternehmens ist die Zufriedenheit unserer Kunden Falls Sie zu irgendeinem Zeitpunkt Schwierigkeiten mit der Funktion oder der Bedienung Ihres Sterling Produktes haben sollten ...

Отзывы: