Page 48
6017 Series Hot Oil Large Temperature Control Units
Servicing the Unit Monthly or Every 500 Hours
•
Lubricate the pump
at the grease fittings with a high-
quality polyurea grease rated at 320ºF or higher.
Recommended: Chevron Black Pearl;
do not over-lubricate
.
•
Adjust
the pump drive
belt tension
. Use the belt tensioning
specifications listed in this chapter on
Page 51
. Make sure
that the motor pulley is properly aligned with the pump
pulley; use a straightedge to check. Tighten motor mounting
bolts after realignment.
•
Inspect the screen in the Y strainer for accumulations of
debris. Clean as needed.
Servicing the Unit Every Three Months
Remove and clean the screen in the Y-strainer. Replace the screen
if it is damaged.