Page 32
6017 Series Hot Oil Large Temperature Control Units
4-2 Shutting Down the Unit
UNIT SHUT DOWN (WITH AUTOVENT SOLENOID OR MANUAL VENT VALVE)
Cool the unit down by switching the
Mode
switch to the "Manual Cool" position. This will
disable the heaters ( i.e. prevent the controller from turning them on) and open the cool solenoid.
Fluid temperature can be monitored on the controller display during cool down. When fluid
temperature is below 120ºF, depress the
PUMP STOP
button to turn the unit off.
4-3 Returning Fluid to the Tank
RETURNING FLUID TO TANK
If the unit is to be moved from one process to another (i.e. mold changes, etc.), the following
steps must be taken to drain the mold and process lines. Note that this is just the opposite of unit
start up/air purge:
1. Cool fluid to 150°F (66°C) maximum.
2. Depress the
PUMP STOP
push button.
3. Close the Return Valve.
4. Open the Blow Off Valve. (with autovent, the valve will open on its own)
5. Depress and hold the
PUMP REVERSE
push-button. The pump will then run in
reverse, drawing fluid from the mold and lines, and into the reservoir tank.
6. Watch the sight glass to prevent overflow of the reservoir tank.
!
CAUTION
The reservoir tank may not have adequate volume
to contain the total system capacity of fluid.
An overflowing reservoir allows hot fluid to escape
and become a potential fire and slip hazard.
The total capacity of the tank can be found on page 14.
If it appears that the tank may overfill, connect a line from the
FILL
port of the reservoir tank to
a
clean
auxiliary container.
Содержание 6017 Series
Страница 29: ...Page 28 6017 Series Hot Oil Large Temperature Control Units Notes ...
Страница 34: ...6017 Series Hot Oil Large Temperature Control Units Page 33 Notes ...
Страница 46: ...6017 Series Hot Oil Large Temperature Control Units Page 45 Notes ...
Страница 52: ...6017 Series Hot Oil Large Temperature Control Units Page 51 ...
Страница 55: ...Page 54 6017 Series Hot Oil Large Temperature Control Units Service Notes ...
Страница 56: ...6017 Series Hot Oil Large Temperature Control Units Page 55 Service Notes ...
Страница 57: ...Page 56 6017 Series Hot Oil Large Temperature Control Units Service Notes ...