REMOVAL
INSTALLATION
Check the packaging for transport damage be-
fore removing the device. Do not use pointed or
sharp objects to open the packaging. Remove
the device, drilling template, screws and dowels
as well as the charging device from the card-
board box.
Attention: The rechargeable battery is not
fully charged and must be fully charged be-
fore commissioning.
1. Removing the front cover: By verticallypulling
the strap on the bottom of the device (refer to pg.
01 / item 2)
2. Removing the internal cover: By slightly
pulling with the index finger in the inspection win-
dow and simultaneously pulling forward.
3. Assembling the rear wall: Check the instal-
lation site for levelness. By means of the drilling
template, fix the rear wall to the wall using the
dowels and screws. Attach the device at a height
of approx. 90 cm above the ground (or 70 cm if
predominantly used by children; distance between
the bottom of the Steripower and the ground).
4. Rechargeable battery connection: charging is
only possible with the cable correctly connected to
the rechargeable battery (refer to pg. 01 / item 7).
5. Charging procedure: Plug the charging device
into the socket (at the bottom of the device on the
left; refer to pg. 01 / item 5). The charging proce-
dure is continued as long as the LED of the char-
ging device is green. Charging duration approx.
24 hrs.
6. Setting the quantity: The liquid quantity is
controlled via a pressure switch. A value of 1.5 ml
is pre-set ex works. When pressing the switch,
the LED flashes red. The switch is located on the
printed circuit board (refer to pg. 13 / item C).
Adjustment steps:
The red LED flashes:
1x = 0,5 ml
6x = 3,0 ml
2x = 1,0 ml
7x = 3,5 ml
3x = 1,5 ml
8x = 4,0 ml
4x = 2,0 ml
9x = 4,5 ml
5x = 2,5 ml
10x = 5,0 ml
Should the liquid quantity be to low or too high,
fine tuning can be performed by turning a
watchmaker‘s screwdriver to the right or left.
(refer to pg. 13 / item L)
Attention: Risk of electrocution!
The Steripower with integrated power sup-
ply unit (art. 10047) must only be installed
by technical personnel. Before assembly,
disconnect the wall cable from the power
supply (e.g. by switching off the fuse).
EN
REMOVAL & INSTALLATION
REMOVAL & INSTALLATION | 06