background image

Safety

SteriPEN

®

Adventurer

Opti

may be used in glass, plastic, ceramic or

metal containers. They all absorb and reflect UV light, thereby
shielding the user from UV exposure. AdventurerOpti should not
be used in quartz containers. The air/water interface at the top
of any drinking container is highly reflective to UV and reflects
UV back into the container.

Optical Water Sensor

SteriPEN

®

Adventurer

Opti

features an advanced proprietary

optical water sensing technology. This is an important safety feature
intended to prevent UV exposure by permitting operation only when
lamp is completely immersed in water. Never attempt to bypass this
feature. If the SteriPEN

®

Adventurer

Opti

does not detect water

within 15 seconds of being activated, it will deactivate.

Agitation of Water

Agitation of the water by stirring with AdventurerOpti or rocking
the container throughout the dose is essential for proper operation
as this insures uniform exposure of all water to germicidal UV light.

Cold Weather Considerations

Bring AdventurerOpti up to a temperature above 32°F/0°C
before using. Battery performance may be adversely affected
by cold weather.

Lamp Life

After Lamp Life = 8,000 Treatments, lamps must be replaced
by manufacturer or licensed technician.

Battery Selection & Installation

SteriPEN

®

Adventurer

Opti

uses two CR123 batteries. CR123

batteries are nominally 3 volts and are available in both
rechargeable and non-rechargeable (disposable) varieties.
One double-cell CR123 battery may also be used.

Use high quality name brand batteries. Our testing has shown
that a single set of non-rechargeable (disposable) CR123’s will

3

4

1

SteriPEN

®

Adventurer

Opti

treats two ranges of

water volume:

A

—up to 0.5 liter (16 fl. oz.)

B

—between 0.5 – 1.0 liter (16 and 32 fl. oz.)

1

Install two CR123 batteries with polarities as shown;
or install one double-cell CR123 battery.

2

Tighten coin screw on battery end cap until snug (do
NOT over-tighten screw as this may cause damage).

3

Remove lamp cover – pull cover off body.

4A

Push Activation button

twice

– green indicator LED

(near button) and white optical sensor (near lamp) will
flash for up to 15 seconds indicating Adventurer

Opti

is

ready to treat up to .5 liter (16 fl. oz.).

4B

Push Activation button

once

– green indicator LED

(near button) and white optical sensor (near lamp) will
flash for up to 15 seconds indicating AdventurerOpti is
ready to treat up to 1 liter (32 fl. oz.).

5

While green indicator LED and white optical sensor
flashes, dip the ultraviolet (UV) lamp into the water
to be treated such that lamp and optical sensor are
completely immersed. When water is detected, lamp
turns on automatically, emitting both UV and visible
light.

IMPORTANT NOTE:

If visible light from UV lamp

is not evident, the AdventurerOpti UV lamp is not on,
and water should not be consumed.

6

Agitate the water throughout the dose by stirring with
the AdventurerOpti until the lamp automatically turns
off. Once lamp turns off, green indicator LED will turn
on to show that the UV dose is complete.

NOTE:

If

red LED turns on after lamp shuts off, the dose was
not complete.

7

Remove AdventurerOpti from water. Dry off lamp and
optical water sensor with clean cloth.

IMPORTANT

NOTE:

Many brands of CR123 batteries have built-in

protection circuitry that instantly disables battery
function when batteries reach a specific low charge
threshold. If this “disable” function is triggered during
operation the AdventurerOpti will be unable to give the
“Low Battery” signal (blinking red LED). Until batteries
are replaced or recharged the AdventurerOpti will
not be operational.

8

To activate the flashlight, press and hold the activation
button for 3 seconds. The flashlight will automatically be
on for 3 minutes; reactivate as needed. To turn off the
flashlight, push the activation button once. To protect
UV lamp when using the flashlight, operate with lamp
cover in place.

5

6

7

2

Thank you for buying your SteriPEN

®

Adventurer

Opti

and

congratulations on your purchase. Years of careful research,
development and testing have gone into the creation of this
unique product.

Directions for Use

40 C.F.R. §156.10(i)(2)

It is a violation of Federal law to use this product in a manner
inconsistent with its labeling.

40 C.F.R. §156.10(i)(2)(ii)

SteriPEN

®

exceeds U.S. EPA Guide Standard and Protocol

for Testing Microbiological Water Purifiers, destroying over
99.9999% of bacteria, 99.99% of viruses, and 99.9% of protozoa
when used as directed. SteriPEN

®

is not a sterilizer.

Operating the SteriPEN

®

Adventurer

Opti

Quick Start Guide

Use SteriPEN

®

Adventurer

Opti

with clear water. Discolored or dirty water

should be pre-filtered until clear prior to SteriPEN

®

Adventurer

Opti

treatment.

See also “Treating Turbid, Murky, or Cloudy Water”

Operating Signals

Green, fast flashing (after button push)

Green, slow flashing: 1 second on,
1 second off (after dose completion)

Green, steady (after dose completion)

Green blinks for 15 seconds followed
by a quick Red flash

Green flash followed by Red flash

Red, steady

Battery Warnings

Red, fast flashing

Green slow blinking with Red flashes

Green, steady with Red flashes

Indicator LED will not come on

Lamp Warnings

Red 2 flashes, Green 2 flashes
(repeating)

Red 3 flashes, Green 1 flash (repeating)

Normal indicator LED function, yet UV
lamp emits no visible light

Unit is armed and ready to treat water

1 liter (32 fl. oz.) dose completed

0.5 liters (16 fl. oz.) dose completed

Time expired, try again. The user has 15
seconds to put the SteriPEN

®

in water

after activation.

(1)

Dry water sensing pins before use.

(2)

Press activation button for 1 second to

activate for 32 oz. timer; again for 16 oz.

(3)

Clean water sensing pins.

Dose incomplete. Repeat treatment.

Low battery warning; replace
or recharge batteries

1 liter (32 Fl. Oz.) dose completed;
battery getting low

0.5 liter (16 Fl. Oz.) dose completed;
battery getting low

(1)

Check battery orientation

(2)

Charge or replace batteries

(3)

Clean battery contacts

(4)

Return SteriPEN

®

for repair

Over 7,900 treatments completed; lamp
replacement needed in under 100 doses

Lamp failure; replace lamp

Lamp failure. Do not consume water.
Follow warranty procedure.

SteriPEN

®

Adventurer

Opti

LED Signals

LED Color and Pattern Display

Indication

8

Содержание Adventurer Opti

Страница 1: ...ver 2 UV Lamp Assembly 3 Optical water sensor 4 Activation Button 5 Indicator LED Light Emitting Diode shows activation status 6 Battery Compartment End Cap 7 Battery Compartment End Cap Screw SteriPEN AdventurerOpti User s Guide See Water in a Whole New Light ...

Страница 2: ... the UV dose is complete NOTE If red LED turns on after lamp shuts off the dose was not complete 7 Remove AdventurerOpti from water Dry off lamp and optical water sensor with clean cloth IMPORTANT NOTE Many brands of CR123 batteries have built in protection circuitry that instantly disables battery function when batteries reach a specific low charge threshold If this disable function is triggered ...

Страница 3: ... and Cleaning When not in use AdventurerOpti should be kept in a clean dry non abrasive area or container AdventurerOpti should not be exposed to ambient temperatures above 140 F 60 C or below 4 F 20 C When storing AdventurerOpti for long periods remove batteries To clean AdventurerOpti wash with a soft cloth and a mild soap solution Rinse soap from device and dry with a clean soft cloth Note that...

Страница 4: ...r If in doubt about volume of water to be treated confirm volume with a measuring device such as a measuring cup Do not store AdventurerOpti for long periods with batteries installed Batteries may in rare instances leak or corrode and cause damage to device When operating properly the AdventurerOpti s UV lamp will emit visible light as well as UV If UV lamp is not emitting visible light it is not ...

Отзывы: