How does SteriPEN
®
Adventurer
Opti
disinfect water?
SteriPEN
®
Adventurer
Opti
uses short wave germicidal UV light
to disinfect water. This range of UV light disrupts the DNA
within bacteria, viruses and protozoa, rendering them unable
to reproduce and therefore, harmless. For more detailed
information, visit our web site at ww.steripen.com.
Testing
At Hydro-Photon, we believe that careful testing is an important
part of successful and responsible product development and
quality control. A wide range of testing has gone into development
and production of your SteriPEN
®
Adventurer
Opti
. To see our full
microbiological test reports conducted at the University
of Arizona, Tucson; University of So. Maine, Portland; University
of Maine, Orono; Ryerson University, Toronto Ontario; A&L
Laboratory, Auburn, ME; and Oregon Health Sciences University,
Portland, visit the “Testing”section of our web site at:
www.steripen.com/testing.html.
Distributors/Importers
© 2010 by Hydro-Photon, Inc.
All rights reserved.
U.S.A.
Hydro-Photon, Inc.
P.O. Box 675
262 Ellsworth Rd.
Blue Hill, Maine 04614 USA
Toll-Free: (888) 783-7473
Tel: (207) 374-5800
Fax: (207) 374-5100
[email protected]
www.steripen.com
SteriPEN
®
water purifiers are sold around the world. To find your nearest
distributor, visit www.steripen.com/dealerlocator.
SteriPEN
®
is tested and certified
by the Water Quality Association
against the US EPA Microbiological
Water Purifier Standard.
• AdventurerOpti is intended for use with clear water but in
emergencies may be used in moderately turbid water. See
"Treating Turbid, Murky or Cloudy Water" section above
before deciding to use SteriPEN
®
on turbid water.
• AdventurerOpti is designed to treat 0.5 or 1.0 liter (16 or 32 fl. oz.)
of clear water. If in doubt about volume of water to be treated,
confirm volume with a measuring device such as a measuring cup.
• Do not store AdventurerOpti for long periods with batteries
installed. Batteries may in rare instances leak or corrode and
cause damage to device.
• When operating properly, the AdventurerOpti’s UV lamp will
emit visible light as well as UV. If UV lamp is not emitting
visible light, it is not functioning properly, and should not be
used until repaired.
• The AdventurerOpti lamp assembly must be clean prior to use.
• If AdventurerOpti is below 32°F/0°C it should be warmed above
32°F/0°C before operating.
• Do not allow impact to the lamp end. If lamp assembly (lamp or
quartz sleeve) is cracked, chipped or damaged, do not operate.
Return to your local distributor/importer for repair.
• Do not use in liquids other than clear water.
• Do not use in water with ice.
• Do not use in water above 140°F/60°C.
• UV light can be harmful to eyes and skin. Never look at an
unshielded UV lamp during operation.
• Do not operate near skin.
• Do not operate near eyes.
• Do not insert into bodily orifices.
• While carefully controlled microbiological testing has been
conducted, use of AdventurerOpti in non-laboratory conditions
may produce results that vary from our laboratory test data.
• Do not use in any manner other than instructed in this
User’s Guide.
Certifications & Patents
Conforms to EN61010-1:1993 + A1 + A2 and EN 61326
Listed 3058969. Conforms to Standard UL 61010A-1
Certified to CAN/CSA Standard C22.2, No. 1010.1-92
U.S.E.P.A. Company #73679, U.S. EPA Establishment #07369-ME-
001 U.S. Patent Numbers 5,900,212 & 6,110,424 & 6,579,495
Patents and patents pending in U.S. and worldwide.
SteriPEN
®
is a registered trademark of
Hydro-Photon, Inc. © 2010 Hydro-Photon, Inc.
All rights reserved.
www.steripen.com
Hydro-Photon, Inc.
P.O. Box 675
262 Ellsworth Rd.
Blue Hill, ME 04614 USA
Tel: (207) 374-5800
Fax: (207) 374-5100
[email protected]
MANOP1002