Attenuator? U
55
US
High Power Alarm?
V
56
US
Low power alarm?
W
57
US
Transmit X
58
UC
Set Address
Y
59
UC+p
Set baud rate
Z
5A
UC+p
Type:
UC
user
command
UC+p user command with parameter
US
user
status/data
request
Note:
Input power is not monitored.
Data requests will be serviced with the amplifier in either local or remote mode. However, for other
commands to be executed, (with the exception of remote enable) the amplifier must be in remote
mode. Commands will be rejected as un-executable with the amplifier in local mode.
6.3 EXAMPLES OF COMMAND AND RESPONSE MESSAGES
Examples of each command type are given in a generalised, ASCII and hexadecimal form using the
address 5 (35H) for specific examples. The expected response message for each command is show
using the same format.
Note:
•
ASCII non-printable characters are enclosed thus < >.
•
The final character in each example is the checksum.
.3.1
Simple Command Message (no return of data)
A
II
Hex
6
Command SC
Enable manual redundancy mode
5
35
Enable auto redundancy mode
6
36
This amplifier to antenna
7
37
This amplifier to load
8
38
Enable RF
E
45
Helix current record top of file
F
46
Go to local
L
4C
Inhibit RF
N
4E
Off O
4F
Remote enable
R
52
Standby S
53
Transmit X
58
> checksum
Command
Gen
<STX> address S <ETX
ASCII
<STX>
5S
<ETX>
g
Hex
02
35
53
03
67
> chec
Response
Gen
<ACK> address S <ETX
ASCII
<ACK>
5S
<ETX>
c
ksum
Hex
06
35
53
03
63
© e2v technologies (uk) limited 2010
DAS768892AA
Version
1,
page
30