14 - MAINTENANCE
The appliance is required to be inspected at least once a year by a professional service person. The compartment below fi rebox (behind
lower access panel) must be cleaned at least once a year, more frequent cleaning may be required due to excessive lint from carpeting,
bedding materials, or other fi brous materials. It is imperative that the burner be cleaned once a year.
A. VENT SYSTEM
•
Annual examination of venting system by a qualifi ed agency is required.
•
IF VENT-AIR INTAKE SYSTEM IS DISASSEMBLED FOR ANY REASON, RE-INSTALL PER INSTRUCTIONS PROVIDED WITH INITIAL
INSTALLATION.
•
The fl ow of combustion air must not be obstructed.
B. GLASS CLEANING & REPLACEMENT
•
Clean glass only when cool and only with non-abrasive cleansers.
•
Do not operate this fi replace with glass/frame assembly removed, cracked or broken.
•
The glass assembly shall only be replaced as a complete unit, as supplied by Stellar Hearth Products.
•
Replacement of glass & frame assembly, must only be performed by a licensed or qualifi ed service person.
DO NOT SUBSTITUTE MATERIALS.
•
Do not strike or slam glass door assembly.
C. REPLACEMENT PARTS LIST
PART
MANUFACTURER
PART NUMBER
Powervent
Enervex
SEE PAGE 17
Valve
Honeywell Smart Valve
SV9501
Pilot
Honeywell Smart Valve
Q3450C1185
Vacuum Switch
Cleveland Controls
AFS-405
Flue Pipe
Approved
SEE PAGE 17
24vac Transformer
Dayton
24vac 40 VA
Orifi ces
Custom
SEE PAGE 6
Glass Media
CRYSTAL
Glass Panel Sizes
CONTACT STELLAR DIRECTLY
VALVE AND ELECTRICAL ACCESS
There is an access panel under the fl oor of the fi rebox should more extensive service be needed. Remove the inner and outer glass
panels. Remove the glass media on the end with the pilot. The end fl oor lifts out; remove the screws and lift it out. Remove the burner and
loosen the pilot bracket. There is a panel under the fl oor you removed. Remove the 6 screws and slide the panel up.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE
IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING. KEEP APPLIANCE AREA
CLEAR OF COMBUSTIBLE MATERIALS, SUCH AS GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS. VAPORS
AND LIQUIDS.
NOTE: INSTALLATION AND REPAIR SHOULD BE DONE ONLY BY QUALIFIED SERVICE PERSON. THE APPLIANCE
SHOULD BE INSPECTED BEFORE USE AND ANNUALLY BY A QUALIFIED SERVICE PERSON. MORE FREQUENT CLEANING
MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIALS, ETC. IT IS IMPERATIVE THAT
CONTROL COMPARTMENTS, BURNERS AND CIRCULATION AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
Содержание 4-SS-2-GL
Страница 2: ...INS_CUST UL REV D Page 2 ...
Страница 20: ...INS_CUST UL REV D Page 20 Figure 8F 2 F HORIZONTAL TERMINATION VENT CAP LOCATION CLEARANCES 8 VENTING ...
Страница 26: ...INS_CUST UL REV D Page 26 9 GALAXY ELECTRIC Figure 9B B INSTALL ...
Страница 27: ...Page 27 16400 7800 GSS REV D 9 GALAXY ELECTRIC C SERVICE TROUBLESHOOTING Figure 9C ...