![Stellar Hearth Products 3-RD-2-GL Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/stellar-hearth-products/3-rd-2-gl/3-rd-2-gl_installation-and-operating-manual_1371587008.webp)
Page 8
INSTALL_3-RD-GL-R REV A
WARNING: NON-COMBUSTIBLE ZONE: USE ONLY NON-COMBUSTIBLE MATERIAL IN THIS AREA FOR ENTIRE WIDTH OF
FIREPLACE. DO NOT USE WOOD, SHEETROCK, ETC., IN THIS ZONE.
NOTE: OTHER CLEARANCES APPLY. ALL CLEARANCES MUST BE MAINTAINED.
REFER TO SPECIFICATIONS 3C FOR MORE INFORMATION.
3 - SPECIFICATIONS
3X .375-16 UNC THREADED ROD
THE HOOD SHALL BE SUPPORTED USING
QTY 3, .375-16 UNC THREADED RODS
TEMPORARY SUPPORTS SHALL BE PROVIDED
FOR INSTALLATION
TOP & BOTTOM
3” [76] STEEL
SURFACE SHALL NOT
BE COVERED OR THE
GLASS WILL NOT
COME OFF
OTHER CLEARANCE NOTES:
DO NOT PLACE ON CARPET, VINYL OR SOFT SURFACES.
COMBUSTIBLE FRAMING AND FINISHING MAY BE PLACED ON THE FIREPLACE ANYWAY BELOW THE BOTTOM OF GLASS VIEWING
PLEASE PLAN FOR THE FINISHING OF THE ELECTRIC ACCESS PRIOR TO ANY FRAMING
TOP & BOTTOM 3” [76] STEEL SURFACE SHALL NOT BE COVERED. TRIM MUST BE REMOVABLE TO INSTALL AND REMOVE GLASS.
FIREPLACE IS NOT
LOAD BEARING
12” [305] CLEARANCE TO COMBUSTIBLES ALL THE WAY AROUND FIREPLACE GLASS
AND TOP AND BOTTOM 3” [76] TRIM TO BE ABLE TO GET THE GLASS OFF
6”
[152]
NO COMBUSTIBLE
MATERIAL WITHIN
6” [152] OF THE TOP OF
THE FIREPLACE
12”
[305]
0
0”
0
0
12”
[305]
Figure 3C