INSTALL_3-RD-GL-R REV A
15 - MAINTENANCE
The appliance is required to be inspected at least once a year by a professional service person. The compartment below firebox (behind
lower access panel) must be cleaned at least once a year, more frequent cleaning may be required due to excessive lint from carpeting,
bedding materials, or other fibrous materials. It is imperative that the burner be cleaned once a year.
B. VENT SYSTEM
•
Annual examination of venting system by a qualified agency is required.
•
IF VENT-AIR INTAKE SYSTEM IS DISASSEMBLED FOR ANY REASON, RE-INSTALL PER INSTRUCTIONS PROVIDED WITH INITIAL
INSTALLATION.
•
The flow of combustion air must not be obstructed.
C. GLASS CLEANING & REPLACEMENT
•
Clean glass only when cool and only with non-abrasive cleansers.
•
Do not operate this fireplace with glass/frame assembly removed, cracked or broken.
•
The glass assembly shall only be replaced as a complete unit.
•
Replacement of glass & frame assembly, must only be performed by a licensed or qualified service person.
•
DO NOT SUBSTITUTE MATERIALS.
•
Do not strike or slam glass door assembly.
Refer to Section 7 - Glass Frame Assembly for more information.
There is an access panel under the floor of the firebox should more extensive service be needed. Remove the media on the screened
section to the left (clockwise) of the pilot. Remove the screws and remove that section from the fireplace. Remove the three-sided wall
that held the screen. Remove the rectangular panel below that to expose the valve.
Refer to Section 3 - Specifications for valve and electrical access schematic.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE
IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING. KEEP APPLIANCE AREA
CLEAR OF COMBUSTIBLE MATERIALS, SUCH AS GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS. VAPORS AND
LIQUIDS.
NOTE: INSTALLATION AND REPAIR SHOULD BE DONE ONLY BY QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD
BE INSPECTED BEFORE USE AND ANNUALLY BY A QUALIFIED SERVICE PERSON. MORE FREQUENT CLEANING MAY BE
REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIALS, ETC. IT IS IMPERATIVE THAT CONTROL
COMPARTMENTS, BURNERS AND CIRCULATION AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
WARNING! RISK OF INJURY! DO NOT remove glass until it is cooled to room temperature. Glass breakage could occur.
See Section 6 for glass installation and removal instructions.
A. VALVE AND ELECTRICAL ACCESS