10 - ELECTRICAL
B.1 ELECTRICAL WIRING SCHEMATIC- AT INSTALL
*
# FUNCTION
1 120 VAC SW2 LIGHTS
2 120VAC SW2 LIGHTS
3 120VAC SW1 MAIN FLAME
4 120 VAC SW1 MAIN FLAME
5 120 VAC SUPPLY
6 NEUTRAL
7 NEUTRAL POWERVENT
8 120VAC POWERVENT
9 24VAC FLUE DAMPER POWER
10 24VAC FLUE DAMPER NEUTRAL
11 SW3 FLUE DAMPER PROVE
12 SW3 DAMPER PROVE
13 CONNECTION FOR EXTERNAL FLUE PRESSURE SWITCH (4 SIDED ONLY)
14 CONNECTION FOR EXTERNAL FLUE PRESSURE SWITCH (4 SIDED ONLY)
NOTES:
120 VOLT LOOP
120 VOLT LOOP
120 VOLT LOOP
120 VOLT LOOP
CONNECT TO CONSTANT POWER SOURCE
CONNECT TO CONSTANT POWER SOURCE
DO NOT SHARE NEUTRAL
FROM SPEED CONTROL
OPTIONAL
OPTIONAL
OPTIONAL. USE PURPLE AND WHITE, NOT RED
OPTIONAL. USE PURPLE AND WHITE, NOT RED
FOUR SIDED ONLY
FOUR SIDED ONLY
# FUNCTION
1 120 VAC SW2 LIGHTS
2 120VAC SW2 LIGHTS
3 120VAC SW1 MAIN FLAME
4 120 VAC SW1 MAIN FLAME
5 120 VAC SUPPLY
6 NEUTRAL
7 NEUTRAL POWERVENT
8 120VAC POWERVENT
9 24VAC FLUE DAMPER POWER
10 24VAC FLUE DAMPER NEUTRAL
11 SW3 FLUE DAMPER PROVE
12 SW3 DAMPER PROVE
13 CONNECTION FOR EXTERNAL FLUE PRESSURE SWITCH (4 SIDED ONLY)
14 CONNECTION FOR EXTERNAL FLUE PRESSURE SWITCH (4 SIDED ONLY)
RS SERIES SHOWN
SHOWN WITH OPTIONAL MECHANICAL FLUE DAMPER
NOT PROVIDED BY FACTORY
INSULATION PAD
(MUST BE CUT IN CENTER TO ACCOMMODATE VENT SIZE)
MUST BE MOUNTED IN
A SERVICABLE LOCATION.
FOLLOW INSTRUCTIONS
INCLUDED WITH THE PDS KIT.
ORIENTATION IS IMPORTANT.
PDS-01
FLUE PRESSURE SWITCH
*JUNCTION BOX WITH
CAPACITOR
CAP
RS012
RS014
RSIF160
RSIF180
VAC
120
120
120
120
AMP
3.2
3.4
4.9
7.3
Supply
Voltage Chart (N/L1)
CAP
RS012
RS014
RSIF160
RSIF180
VAC
120
120
120
120
AMP
1.2
1.4
2.9
5.3
HP
1/9
1/7
3/7
13/16
Powervent
Voltage Chart
To light the fireplace: Activate the switch.
The fireplace has a pre and post timer, set at the factory for 30 seconds.
The powervent will start after the switch is activated.
The flame will not turn on for 30-60 seconds after switch is activated
and the powervent will run for 30 seconds after it has been shut off.
Figure 10B.1