SAFETY

 

ELECTRIC SHOCK CAN KILL 

-  Disconnect  the  power  supply  before  working  on 
the welding machine. 
- Do not work with deteriorated cable sheaths. 
- Do not touch bare electrical parts. 
-  Ensure  that  all  the  panels  covering  the  welding 
machine  are  firmly  secured  in  place  when  the 
machine is connected to the mains supply. 
-  Insulate  yourself  from  the  work  bench  and  from 
the  floor  (ground):  use  insulating  footwear  and 
gloves. 
-  Keep  gloves,  footwear,  clothes,  the  work  area 
and this equipment clean and dry. 
 

PRESSURISED CONTAINERS CAN EXPLODE IF 
WELDED. 

When working with a welding machine: 
- do not weld pressurised containers . 
- do not weld in environments containing explosive 
powders or vapours. 
 

THE 

RADIATIONS  GENERATED 

BY  THE 

WELDING ARC  CAN  DAMAGE  THE  EYES AND 
CAUSE BURNING OF THE SKIN. 

- Provide suitable protection for the eyes and body. 

- It is indispensable for contact lens wearers to 
protect  themselves  with  suitable  lenses  and 
masks. 

 

NOISE CAN DAMAGE YOUR HEARING. 

-  Protect  yourself  suitably  to  avoid  hearing 
damage. 
 

FUMES  AND  GASES  CAN  DAMAGE  YOUR 
HEALTH. 

- Keep your head out of the reach of fumes. 
- Provide suitable ventilation of the work area. 
- If  the ventilation  is  not  sufficient,  use  an  exhaust 
system that sucks from the bottom. 

 
HEAT,  SPLASHES  OF  MOLTEN  METAL  AND 
SPARKS CAN CAUSE FIRES. 

- Do not weld near inflammable materials. 
- Avoid  having  any  type  of  fuel  with  you  such  as 
cigarette lighters or matches. 
- The welding arc can cause burns. Keep the tip of 
the  electrode  far  from  your  body  and  from  other 
persons. 

 

PREVENTION OF ELECTRIC SHOCKS  

Take the following precautions when working with a 
welding machine: 
- keep yourself and your clothes clean. 
- do not be in contact with damp or wet parts when 
working with the welding machine. 
- maintain suitable insulation against electric shock. 
If the operator has to work in a damp environment, 
he  must  take  extreme  care  and  wear  insulating 
footwear and gloves. 
-  check  the  machine  power  cable  frequently:  it 

must be free from damage to the insulation. BARE 
CABLES  ARE  DANGEROUS.  Do  not  use  the 
machine if the power cable is damaged; it must be 
replaced immediately. 
-  if  it  is  necessary  to  open  the  machine,  first 
disconnect  the  power  supply.  Wait  5  minutes  to 
allow  the  capacitors  to  discharge.  Failure  to  take 
this  precaution  may  expose  the  operator  to 
dangerous risks of electric shock. 
-  never  work  with  the  welding  machine  if  the 
protective cover is not in place. 
-  ensure  that  the  earth  connection  of  the  power 
supply cable is perfectly efficient. 
This  machine  has  been  designed  for  use  in  a 
professional  and  industrial  environment.  For  other 
types  of  application  contact  the  manufacturer.  If 

electromagnetic disturbances 

are found it is the 

responsibility  of  the  machine  user  to  solve  the 
problem  with  the  technical  assistance  of  the 
manufacturer. 

It is forbidden for people with PACEMAKERS to 
use or come near the machine. 

 

 

 

PREVENTION OF BURNS  

To  protect  your  eyes  and  skin  from  burns  and 
ultraviolet rays: 
- wear dark glasses. Wear suitable clothing, gloves 
and footwear. 
- use  masks  with  closed  sides,  having  lenses  and 

WARNING 

Содержание SKY-MIG 353K

Страница 1: ...SSMACHINE MANUAL DE INSTRUCCIONES PARA M QUINA DE SOLDAR SKY SKY SKY SKY MIG 353K MIG 353K MIG 353K MIG 353K 353S 353S 353S 353S SKY SKY SKY SKY MIG 453K MIG 453K MIG 453K MIG 453K 453S 453S 453S 453S...

Страница 2: ...Castegnero Vicenza Italy Tel 39 0444 639525 Fax 39 0444 639682 www stelgroup it The following harmonized standard in force within the EEA has been used in the design EN 60974 1 ed 4 Arc welding equipm...

Страница 3: ...ard in force within the EEA has been used in the design EN 60974 1 Arc welding equipment Part 1 Welding power sources EN 60974 10 Arc welding equipment Part 10 Electromagnetic compatibility EMC requir...

Страница 4: ...a dei fumi Provvedere per una ventilazione adeguata dell area di lavoro Se la ventilazione non sufficiente usare un aspiratore che aspiri dal basso IL CALORE GLI SCHIZZI DEL METALLO FUSO E LE SCINTILL...

Страница 5: ...tecnologie applicate Il circuito microprocessore controlla ed ottimizza il trasferimento dell arco indipendentemente dalla variazione del carico e dell impedenza dei cavi di saldatura I comandi sul p...

Страница 6: ...one INSTALLAZIONE ATTENZIONE Questa apparecchiatura in CLASSE A non e destinata all uso in ambienti residenziali dove la potenza elettrica e fornita dal sistema pubblico di alimentazione a bassa tensi...

Страница 7: ...llegare correttamente a terra l apparecchiatura pu provocare shock elettrici pericolosi per l utente e un non corretto funzionamento del generatore SOLLEVAMENTO ATTENZIONE SKY MIG 353K peso 87kg 191lb...

Страница 8: ...ZIONI INTERNE per TOP 304 TS 1 Pulsante Spurgo Gas 2 Pulsante Avanzamento Filo SUB MENU SELEZIONE TIPO PARTENZA Questo tipo di settaggio permette di ottimizzare la fase di innesco a seconda delle esig...

Страница 9: ...ilo o corrente Se il generatore viene spento e riacceso mantiene in memoria l ultima impostazione SMALTIMENTO APPARECCHIATURE ELETTRICHE ED ELETTRONICHE Non smaltire le apparecchiature elettriche assi...

Страница 10: ...ause burns Keep the tip of the electrode far from your body and from other persons PREVENTION OF ELECTRIC SHOCKS Take the following precautions when working with a welding machine keep yourself and yo...

Страница 11: ...and of the impedance of the welding cables The controls on the front panel allow easy programming of the welding sequences depending on the operating requirements The electronic components are enclos...

Страница 12: ...ower supply voltage Maximum power supply current Maximum effective power supply current identifies the line fuse D OTHER CHARACTERISTICS Degree of protection INSTALLATION WARNING This Class A equipmen...

Страница 13: ...er with a slow burning type fuse s In the event of damage to the power cable replacement or repair must be performed by a qualified person at an approved service centre EARTHING To ensure user protect...

Страница 14: ...MIG 2T welding mode indicating led FRONT PANEL DESCRIPTION SKY MIG 453K 553S 1 Machine live led 2 Overtemperature Led 3 Thickness Voltage Display 4 Voltage Led 5 Thickness Led 6 Wire Speed Welding Cu...

Страница 15: ...seconds the button PURGE and INCH 3 The displays show START Str and the type of start selected 4 Pressing INCH button is possible select the type of start LOW Lo MEDIUM ME HIGH HI After 3 seconds the...

Страница 16: ...s the owner of the equipment you should get information on approved collection systems from our local representative By applying this European Directive you will improve the environment and human heal...

Страница 17: ...chutzbrille Tragen Sie angemessene Kleidung Handschuhe und Schuhwerk Benutzen Sie Kopfschutzhauben mit geschlossenen Seiten sowie Linsen und Schutzgl ser gem Standard Schutzstufe DIN 10 Weisen Sie Per...

Страница 18: ...s Problem mit Hilfe des technischen Kundendiensts des Herstellers zu l sen ALLGEMEINE EIGENSCHAFTEN Diese neue Reihe von Schwei ger ten ist mit einer elektronischen Stabilisierung ausgestattet welche...

Страница 19: ...6935200020 19 TECHNISCHE DATEN A C D B...

Страница 20: ...chts die Luftzirkulation die durch den eingebauten L fter gesichert wird behindert Die inneren Bauteile ben tigen eine ausreichende K hlung Stellen Sie sicher dass der L fter keine Ablagerungen oder S...

Страница 21: ...rahtr ckbrandzeit Gasnachstr mzeit 8 Encoder zur Reguilierung des Spannung Funktionsparameter 9 Encoder zur Regulierung des Drahtgeschwindikeit 10 Taste zur Wahl des Schwei modus 11 Led Anzeige MIG 4...

Страница 22: ...dann lassen Sie den Knopf los Die Led Anzeige des gew hlten Modus wird dann blinken und HS anzeigen Nun k nnen Sie den hot start von 0 bis 50 des gew hlten Schwei stroms mit Encoder 6 max 400A einste...

Страница 23: ...ndler Informationen ber ein lokales autorisiertes Sammel bzw Entsorgungssystem einholen Indem Sie diese Europ ische Richtlinie befolgen helfen Sie mit bei der Verbesserung der Umweltbedingungen und de...

Страница 24: ...iadamente para evitar da os TANTO LOS HUMOS COMO LOS GASES PUEDEN CAUSAR DA OS A SU SALUD Alejar la cabeza de las emanaciones de humos Disponer una buena ventilaci n del rea de trabajo De no ser sufic...

Страница 25: ...ad gracias a las avanzadas tecnolog as aplicadas El circuito microprocesador controla y optimiza la transferencia del arco independientemente de la variaci n de la carga y de la impedancia de los cabl...

Страница 26: ...en edificios residenciales conectados directamente a la red p blica de BT Podr an presentarse dificultades potenciales para garantizar la compatibilidad electromagn tica en dichos ambientes a causa de...

Страница 27: ...namiento incorrecto del generador LEVANTAMIENTO ATENCI N SKY MIG 353K peso 87kg 191lbs SKY MIG 453K peso 105kg 231lbs SKY MIG 353S TOP 304TS peso 128kg 282lbs SKY MIG 453S TOP 304TS peso 128kg 282lbs...

Страница 28: ...dad del hilo DESCRIPCI N DE LAS REGULACIONES INTERNAS para TOP 304 TS 1 Bot n purga gas 2 Bot n avance hilo SUB MEN SELECCI N DEL TIPO DE CEBADO Este tipo de configuraci n permite optimizar la fase de...

Страница 29: ...de hilo o corriente Si l equipo vien parado y encendido tiene siempre en memoria la ultima impostacion ELIMINACI N DE APARATOS EL CTRICOS Y ELECTR NICOS No eliminar nunca los aparatos el ctricos junto...

Страница 30: ...5 1 5 6 5 3 5 7 5 4 6 2 6 2 8 6 6 4 7 8 6 5 7 7 7 2 12 7 4 10 4 7 6 10 2 8 3 15 6 8 5 13 5 8 9 4 17 8 9 6 16 5 9 10 5 20 10 8 18 8 10 WIRE 1mm Fe GAS Mixture 82 Ar 18 CO2 A B C D E F D E F D E F 1 0 8...

Страница 31: ...4 1 0 1 2 1 0 1 1 1 0 1 10 2 0 1 8 2 0 1 6 2 0 2 4 3 0 2 1 3 0 1 8 3 0 2 8 4 0 2 4 4 0 1 10 4 0 2 10 5 0 2 5 5 0 2 1 5 0 WIRE 1 2mm Fe GAS Mixture 82 Ar 18 CO2 A B C D E F D E F D E F 1 10 2 0 1 8 2 0...

Страница 32: ...SKY MIG 453S WIRE 0 8mm Fe GAS Mixture 82 Ar 18 CO2 A B C D E F D E F D E F 1 7 1 4 3 1 2 0 8 1 8 1 2 0 8 2 2 5 2 9 4 1 6 1 3 2 1 5 1 2 8 2 10 3 13 6 1 8 2 3 6 1 9 2 4 3 1 4 14 3 1 10 2 4 4 2 1 3 5 4...

Страница 33: ...E F D E F 1 3 1 5 0 1 1 1 0 2 1 1 1 0 2 1 10 2 0 1 2 1 5 0 3 1 2 1 5 0 3 2 8 3 0 1 3 2 0 3 1 3 2 0 3 3 2 5 0 1 4 3 0 2 1 4 3 0 2 3 5 6 0 1 5 4 0 1 1 5 4 0 1 WIRE 1mm Fe GAS Mixture 82 Ar 18 CO2 A B C...

Страница 34: ...E F 1 3 1 5 0 1 1 1 5 0 1 1 2 0 1 9 2 0 1 2 1 5 0 1 2 2 0 2 9 3 0 1 3 2 0 1 3 3 0 3 2 5 0 1 4 2 0 1 4 3 0 1 3 4 6 0 1 5 3 0 1 5 3 0 1 3 6 8 0 1 6 3 0 1 6 4 0 1 WIRE 1 2mm INOX GAS Mixture 98 Ar 2 CO2...

Страница 35: ...6935200020 35 WIRING DIAGRAM SKY MIG 353K SKY MIG 453K...

Страница 36: ...6935200020 36 SKY MIG 353S SKY MIG 453S...

Страница 37: ...6935200020 37 SKY MIG 553S TOP 304 TS...

Страница 38: ...6935200020 38 TOP 504 TS...

Страница 39: ...14 15 16 17 18 19 20 21 22 23 2 R Plate SF 170 200 PA66GF50 Pressure arm 30mm Assembly Pressure adjustment unit Retaining screw Wire inlet guide PA66 ID 3 0 L 40 Torch adapter Connecting screw M12x1...

Страница 40: ...Gear to motor Intermediary gear Gear with main axel Pressure arm 30mm assembly left Pressure arm 30mm assembly right Pressure adjustment unit red Retaining screw Wire inlet guide PA66 ID 3 0 L 40 Wire...

Страница 41: ...or pressure arm left Torsion Spring for pressure arm right Pressure adjustment unit red Pan head screw M5x10mm Intermediate wire guide Drive gear 37mm Coverplate Retaining screw Torch adapter Connecti...

Страница 42: ...935200020 42 CONNECTIONS MACHINE FRONT CONNECTIONS 1 2 3 4 5 6 3 4 2 6 5 N DESCRIPTION 1 TORCH CONNECTION 2 ON OFF 3 COMM 3 STEP not available on 353K 4 COMM 10 STEP 5 XL 1 not available on 353K 6 XL...

Страница 43: ...SE 1 3 FUSE 2 4 AWC OPTIONAL OPTIONAL 5 14 PIN 6 POSITIVE 7 COOLING LIQUID CONNECTION OPTIONAL 8 COOLING LIQUID CONNECTION OPTIONAL WATER COOLER 4 PIN CONNECTOR PIN DESCRIPTION 1 Power supply common 2...

Страница 44: ...CONNECTIONS WIRE FEEDER REAR CONNECTIONS 1 2 3 4 N DESCRIPTION 1 14 PIN 2 GAS 3 POSITIVE 4 COOLING LIQUID INPUT 5 COOLING LIQUID OUTPUT 5 1 3 2 N DESCRIPTION 1 TORCH CONNECTION 2 COOLING LIQUID CONNEC...

Страница 45: ...6935200020 45 Info www stelgroup it tel 39 0444 639525...

Отзывы: