background image

 

 

6918900030

 

 

 

24

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
CONNECTIONS 

 

 

 

 

N° 

DESCRIPTION 

CODE 

 









10 

11 

12 
13 
14 
15 
16 
17 
18 
19 
20 
21 
22 
23 
24 
25 
26 
27 
28 
29 
30 
31 
32 
33 
34 
35 
36 
37 
38 
39 
40 
41 
42 
43 
44 
45 
46 
47 
48 
49 
50 
51 
52 
53 
54 
55 
56 
57 
58 

 

Instrumental Support 

Instrumental Plate 

Instruments panel protection 

Fixed Socket 

Knob d.29 

Front panel 

Fixed sockets support 

Logic pcb 

Motor Wire Feeder 

Resistance 

Screw 

Copper Connection 

Inverter Support 

Base 

Auxiliary transformer 

Output inductance 

Spacer 

Motor pcb 

Spacer 

Regulation pcb 

Cover 

Support 

Thermostat 

Inverter pcb 

Filter pcb 

Gas Connector support 

Cap 

Switch 

Fuse holder 

Fuse 

Cable 

Cable Grommet 

Switch Support 

Handle Support 

Handle Spacer 

Spacer 

Fan 

Electro Valve 

Screw 

Fan support 

Micro Switch 

Handle 

Reel holder 
Screw Cork 

Hinge 

Metal pcb protection 

Purge/Inch Label 

Internal Support 

No Gas Label 

Hand Screw 

Wire Feeder Support 

Spacer 

Euro Connector 

Rool Screw 

Rool 

Wire Feeder 

Side Panel 

Sliding Closing 

 

 

6203670T 
66089700 
66077700 
64280000 
66079800 

6607510C 
620365BS 

61235500 
64239000 
65030400 

62039500 
6203710T 

6203620C 

65844000 
61250400 
63180000 
61238200 

61235600 

6203630A 
6203740A 

65023700 
61248800 
61356000 

6203660C 
6607530C 

64664000 
64180000 
64250000 
64439000 
66078500 

6203680C 
6607520C 
6607870C 

63342000 

61133100 

61703000 

6203730T 
64132000 

6202120C 

66470000 

6607540C 

66468000 
6203720T 
66093600 
6203690T 
66625000 
66632000 
6204430T 
63514000 
63186000 
63469000 
63160000 

61191500 

6203640A 

664710000 

 

Содержание MIGGY 171

Страница 1: ...918900030 1 MANUALE DI ISTRUZIONE PER SALDATRICE INSTRUCTION MANUAL FOR WELDING MACHINE BETRIEBSANLEITUNG FÜR SCHWEIßERÄTE MIGGY 171 MIGGY 171 MIGGY 171 MIGGY 171 Info www stelgroup it tel 39 0444 639525 ...

Страница 2: ... 639682 www stelgroup it The following harmonized standard in force within the EEA has been used in the design EN 60974 1 Arc welding equipment Part 1 Welding power sources EN 60974 10 Arc welding equipment Part 10 Electromagnetic compatibility EMC requirements Additional information Restrictive use Class A equipment intended for use in locations other than residential By signing this document the...

Страница 3: ...A SALUTE Tenere il capo fuori dalla portata dei fumi Provvedere per una ventilazione adeguata dell area di lavoro Se la ventilazione non è sufficiente usare un aspiratore che aspiri dal basso IL CALORE GLI SCHIZZI DEL METALLO FUSO E LE SCINTILLE POSSONO PROVOCARE INCENDI Non saldare vicino a materiali infiammabili Evitare di portare con sé qualsiasi tipo di combustibile come accendini o fiammiferi...

Страница 4: ...dei cavi di saldatura I comandi sul pannello frontale consentono una facile programmazione delle sequenze di saldatura in funzione delle esigenze operative La tecnologia inverter usata ha permesso di ottenere generatori con peso e dimensioni estremamente contenuti ridotto consumo energetico eccellente risposta dinamica fattore di potenza e rendimenti molto alti caratteristiche di saldatura miglior...

Страница 5: ...i rete che si discostano fino al 20 dal valore nominale Tensione nominale 230V tensione minima 184V tensione massima 276V Miggy 171 Fuse 16A COLLEGAMENTO Prima di effettuare connessioni elettriche tra il generatore di corrente e l interruttore di linea accertarsi che quest ultimo sia aperto Il quadro di distribuzione deve essere conforme alle normative vigenti nel paese di utilizzo L impianto di r...

Страница 6: ...fuoriuscita del filo dalla torcia tenere chiuso lo sportello laterale mentre si compie questa operazione Spegnere la macchina portando l interruttore di linea in posizione OFF Riavvitare il tubetto portacorrente e l ugello Regolare la frizione del trainafilo una regolazione più accurata sarà possibile dopo alcune prove Impostare il valore del post gas con il potenziometro a vite Impostare il valor...

Страница 7: ...A MIG NO GAS Per l impiego di un filo animato speciale che prevede una saldatura senza impiego di gas procedere in questo modo 1 Collegare il cavo massa alla presa positiva del generatore 2 Inserire il connettore della torcia MIG nella presa centralizzata euro e avvitare la ghiera 3 Controllare la posizione del cavo cambio polarità aprendo lo sportello laterale per la saldatura MIG con FILO ANIMAT...

Страница 8: ... ad un impianto di riciclo ecocompatibile In qualità di proprietario delle apparecchiature dovrà informarsi presso il nostro rappresentante in loco sui sistemi IN CASO DI CATTIVO FUNZIONAMENTO RICHIEDETE L ASSISTENZA DI PERSONALE QUALIFICATO DUTY CYCLE E SOVRATEMPERATURA Il ciclo di intermittenza è la percentuale di utilizzo della saldatrice su 10 minuti che l operatore deve rispettare per evitare...

Страница 9: ...cause burns Keep the tip of the electrode far from your body and from other persons PREVENTION OF ELECTRIC SHOCKS Take the following precautions when working with a welding machine keep yourself and your clothes clean do not be in contact with damp or wet parts when working with the welding machine maintain suitable insulation against electric shock If the operator has to work in a damp environmen...

Страница 10: ...allowed the following to be obtained machines with extremely low weight and compact dimensions reduced energy consumption excellent dynamic response very high power factor and yields better welding characteristics viewing of the data and of the set functions on the display The electronic components are enclosed in a sturdy structure that is easy to carry and cooled with forced air by fans with low...

Страница 11: ...m a mains voltages differing by 20 from the rated mains value example 230V rated Minimum voltage 184V maximum voltage 276V Miggy 171 Fuse 16A CONNECTION Before making the electrical connections between the welding machine and the line switch ensure that the switch is turned off The distribution panel must comply with the regulations in force in the country of use The mains system must be of the in...

Страница 12: ... wire advance button to make the feeding motor run until the wire comes out of the torch keep the side door closed while performing this operation Switch off the machine turning the line switch to OFF position 12 Screw the current supply pipe and the nozzle back on 13 Regulate the friction of the wire feeder a more accurate regulation will be possible after a few tests 14 Set the post gas value wi...

Страница 13: ... opening the side door for MIG welding with special CORED WIRE without the use of gas it must be in position Now proceed as in the instructions in the paragraph PREPARING FOR MIG WELDING WITH GAS starting from point 6 ignoring point 14 and of course all the references to gas coming out of the torch FRONT PANEL DESCRIPTION 1 Machine live led 2 Welding enabled led 3 Over temperature led 4 Synergic M...

Страница 14: ...As the owner of the equipment you should get information on approved collection systems from our local representative By applying this European Directive you will improve the environment and human health IN CASE OF MALFUNCTIONS REQUEST ASSISTANCE FROM QUALIFIED PERSONNEL DUTY CYCLE AND EXCESSES TEMPERATURE The duty cycle is the percentage of use of the welding machine within 10 minutes which the o...

Страница 15: ...ine entflammbaren Dinge mit sich wie Feuerzeuge oder Streichhölzer Der Lichtbogen kann Brände verursachen Halten Sie die Spitze der Elektrode von Ihrem Körper sowie von Personen in Ihrer Nähe fern VORSICHTSMASSNAHMEN UM EINEN ELEKTROSCHOCK ZU VERHINDERN Treffen Sie folgende Vorkehrungen wenn Sie mit einem Schweißgerät arbeiten Halten Sie sich und Ihre Kleidung sauber Berühren Sie keine feuchten od...

Страница 16: ...sorschaltung steuert und optimiert den Transfer des Lichtbogens ungeachtet der Lastschwankung und des Schweißkabelwiderstands Die Steuerung an der Frontplatte ermöglicht ein einfaches Programmieren der Schweißfolge in Abhängigkeit der Arbeitsanforderungen Die eingesetzte Inverter Technologie ermöglicht folgende Punkte Maschinen mit extrem geringem Gewicht und kompakten Abmessungen geringerer Energ...

Страница 17: ...mit den Mitarbeitern des Verteilungsnetzes zu halten ob das Gerät angeschlossen werden kann Der einwandfreie Betrieb des Geräts wird durch eine korrekte Inbetriebnahme gewährleistet deshalb müssen Sie wie folgt vorgehen Stellen Sie das Gerät so auf dass nichts die Luftzirkulation die durch den eingebauten Lüfter gesichert wird behindert Die inneren Bauteile benötigen eine ausreichende Kühlung Stel...

Страница 18: ... ARC FORCE Wert einstellen ANEITUNG ZUM WIG SCHWEISSEN 1 Sich an die vorab gegebenen Anleitungen betreffend den Primäranschluss und die Installation halten 2 Das Massekabel an die positive Buchse des Generators anschließen 3 Den Brenneranschluss an die negative Buchse der Maschine anschließen 4 Den Umschalter auf die WIG Schweißposition stellen 5 Die Gasflasche Argon an die eigens hierfür vorgeseh...

Страница 19: ...e der Druckknopf betätigt bleibt in dem Augenblick in dem man den Druckknopf wieder auslässt beginnt die Gasnachströmung für den vorab durch den Schraubenpotentiometer eingestellten Zeitraum 17 Mit dem Potentiometer die Schweißspannung einstelle 18 Mit dem Potentiometer die Drahtgeschwindigkeit einstellen 19 Die Maschine einschalten indem man den Schalter auf dem Frontpaneel auf ON stellt 20 Mit d...

Страница 20: ...ionales Recht müssen verbrauchte Elektro und Elektronikgeräte getrennt gesammelt und einer umweltgerechten Wiederverwertung zugeführt werden Als Eigentümer des Geräts sollten Sie bei Ihrem lokalen Händler Informationen über ein lokales autorisiertes Sammel bzw Entsorgungssystem einholen Indem Sie diese Europäische Richtlinie befolgen helfen Sie mit bei der Verbesserung der Umweltbedingungen und de...

Страница 21: ...6918900030 21 WIRING DIAGRAM ...

Страница 22: ...6918900030 22 EXPLODED VIEW EXPLODED VIEW WIRE FEEDER N 56 6348100000 631860000 664620000 1 2 ...

Страница 23: ...6918900030 23 SPARE PARTS LIST ...

Страница 24: ...rommet Switch Support Handle Support Handle Spacer Spacer Fan Electro Valve Screw Fan support Micro Switch Handle Reel holder Screw Cork Hinge Metal pcb protection Purge Inch Label Internal Support No Gas Label Hand Screw Wire Feeder Support Spacer Euro Connector Rool Screw Rool Wire Feeder Side Panel Sliding Closing 6203670T 66089700 66077700 64280000 66079800 6607510C 620365BS 61235500 64239000 ...

Страница 25: ...NECTION PIN DECSRIPTION EARTH CLAMP A NEGATIVE MMA ELECTRODE B POSITIVE TYPE CONNECTION PIN DECSRIPTION TIG TORCH C NEGATIVE TIG LIFT EARTH CLAMP B POSITIVE TYPE CONNECTION PIN DECSRIPTION MIG TORCH C POSITIVE MIG EARTH CLAMP A NEGATIVE A B C ...

Страница 26: ...6918900030 26 ...

Страница 27: ...6918900030 27 Info www stelgroup it tel 39 0444 639525 ...

Отзывы: