SBS-PF-300/50A: 4V/4Ah
•
SBS-PF-100/10B: 4V/4Ah
•
SBS-PF-300/50B: 4V/4Ah
•
SBS-PF-150/10B: 4V/4Ah
•
SBS-PF-300/50C: 4V/4Ah
3.2.2 RATED VOLTAGE: For SBS-BW-1T/60*80: AC 9V.
For SBS-PF-A150/20, SBS-PF-60W, SBS-PF-300W, SBS-PF-
150W, SBS-PF-100W: AC 6V.
AC9V.
3.2.3 Backup power nonstop service time: Not shorter than
10 hours after complete charge (for the SBS-PF-A150/20
model: 96 hours, for the SBS-BW-1T/60*80 model: 48 hours;
for the SBS-PF-600/100 model: 168 hours).
4. DISPLAY CHARACTERISTICS
Weight window:5 digits
Unit price window:5 digits
Total amount window:6 digits
5. INSTALLATION
Pull out the down-lead of load cell from the pole, and insert
the plug into the indicator, then fix the pole and indicator.
For platform scale without pole, you just connect the down-
lead of load cell with indicator.
6. BEFORE USE
6.1 Preparation before use.
6.2 Put the scale on a solid and smooth platform. The scale
should avoid vibration, violent air current, direct sunshine
and high temperature. It is recommended to level the device
using adjustable feet (in the case of models possessing feet).
6.3 After connecting with AC power, please check whether
the AC indicator lamp lights up, if not, check relevant parts.
6.4 After power on, the scale will do self-check immediately,
during which you can find whether display and zero position
is normal.
6.5 The first thirty minutes after power on is for pre-heating,
please don’t perform weighing during that time.
6.6 For the SBS-PF-A150/20 and SBS-BW-1T/60*80 scale
models, the connection between the scale head and the
scale platform is wireless. The communication between
the head and the platform is being established right after
switching on the scale head and the scale platform. The scale
platform is equipped with three control lights:
•
AC – means that the storage battery of the platform is
charging (AC power is connected)
•
Low Voltage – means that the platform storage battery
needs to be charged
•
SIGNAL – after proper wireless connection between
the scale head and the scale platform this light will
be blinking.
3. ELECTRICAL CHARACTERISTICS
3.1 Alternating current characteristics:
3.1.1 Working voltage: 230V (+10%~-15%);
3.1.2 Power frequency: 50+2%Hz
3.2 Direct current characteristics:
3.2.1 Storage battery capacity:
•
SBS-PF-100A1: 6V 4Ah;
•
SBS-PF-100A8 / SBS-PF-100A8 foldable: 4V 4Ah;
•
SBS-PF-A150/20 / SBS-PF-60W, SBS-PF-300W, SBS-
PF-150W, SBS-PF-100W: scale head storage battery:
4V/4Ah, scale platform storage
•
battery: 4V/4Ah;
•
SBS-BW-1T/60*80: scale head storage battery:
6V/4Ah, scale platform storage
•
battery: 4V/4Ah
•
SBS-PF-600/100: 4V6Ah
•
SBS-PF-60/10A: 4V/4Ah
•
SBS-PF-100/10A: 4V/4Ah
•
SBS-PF-150/10A: 4V/4Ah
SBS-PF-100A1
SBS-PF-100A8
SBS-PF-100A8 foldable
SBS-PF-600/100
BS-BW-1T/60x80
SBS-PF-60/10A
SBS-PF-100/10A
SBS-PF-150/10A
SBS-PF-300/50A
SBS-PF-300/50B
SBS-PF-100/10B
SBS-PF-150/10B
SBS-PF-300/50C
1
2
3
1
3
2
4
4
4
4
1
4
5
4
3
4
4
4
5
4
1
4
3
4
6
4
3
4
4
4
1
4
1
4
2
4
3
4
4
4
4
4
3
4
5
4
1
Note:
e = d
2.3 ERROR RANGE
Weight
(described as e)
Error range
Outgoing
inspection
Inspection after
repair
0≤M≤500
e
±0.5e
±1.0e
500e<m≤2000e
±1.0e
±2.0e
2000e
<M≤3000
e
±1.5e
±3.0e
Note: e is verification interval
Device description
1.
Head with display and buttons
2.
Head rod
3.
Weighing platform
4. Feet
5.
Foldable head rod
6. Wheels
7.
A bag for the panel with the display
Legend
Battery type
Rechargeable lead-acid, DC 4V/4Ah
Adapter type
AC 230V / 50 Hz ~ 0.3A / DC 7V 0.5A
Adapter cable
lenght [m]
1,5
Maximum
working
time without
charging [h]
40
Battery capac-
ity [mAh]
4000
Division [g]
10
50
10
Maximum
load [kg]
60
300
150
100
Minimum
load [kg]
0,2
1
0,2
Display type
LED
Maximum
distance
between the
panel and
the weighing
platform [m]
20
Zero range
~50g
~6kg
~3kg
-
Tare range
[kg]
~60
~300
~150
-
Channel spac-
ing [MHz]
10
The number
of channels
8
Modulation
type
GFSK
Operation
frequency
[MHz]
2410-2480
The product satisfies the relevant safety
standards.
Read instructions before use.
The product must be recycled.
WARNING! or CAUTION! or REMEMBER!
Applicable to the given situation. (general
warning sign).
ATTENTION! Electric shock warning!
Class II protection device with double
insulation.
SBS-PF-A150/20 | SBS-PF-60W | SBS-PF-300W
SBS-PF-150W | SBS-PF-100W
4
1
4
4
4
3
4
7