1. Loosen the threaded ring
5
on the prefilter
cover
4
by turning it counterclockwise.
2. Lift the prefilter cover
4
with the threaded
ring off the pump housing.
3. Insert the large O-ring seal
20
into the
groove on the pump housing.
4. Insert the prefilter
32
into the pump.
The prefilter is already inserted into the pump
at the factory.
5. Place the prefilter cover
4
on the pump
housing.
6. Guide the threaded ring over the prefilter
cover.
7. Turn the threaded ring clockwise until it is
hand-tight.
8. Insert the small O-ring seal
18
into the prefilter cover.
9. Screw the hose adapter
21
clockwise into the prefilter cover until it is hand-tight.
10. Place the medium O-ring seal
19
into the recess of the pump outlet
28
.
11. Screw a hose adapter
21
clockwise into the pump outlet until hand-tight.
The pump is ready for operation. You can now connect it to the lines.
Mounting the pump on the base plate
1. Insert the threaded screws of the screw set
for fastening the pump
13
from below into the
two hexagonal holes in the base plate
12
.
2. Place the pump
3
on the base plate
12
so
that the threads protrude through the
fastening opening in the pump base.
3. Push the washer and then the serrated lock
washer over the screw thread.
4. Put on one winged screw each and tighten it.
The pump is mounted on the base plate.
5. Connect the base plate
12
to the filter vessel
2
.
The base plate is connected to the filter vessel.
Preparing the filter vessel
1. Undo the locking ring
7
by turning the screw
counter-clockwise. Use the Allen wrench
22
for
this purpose.
2. Put aside the locking ring and its screws.
3. Mount the drainage screws set
11
on the
drainage opening
24
.
1
5
4
20
32
19
18
28
21
36
36
2
3
34
Содержание 040310
Страница 2: ......
Страница 3: ...36 16 18 19 20 3 1 2 3 6 7 8 10 11 12 13 14 15 16 22 23 17 4 5 21 9 3 de...
Страница 4: ...A 24 25 27 29 30 29 28 31 32 33 B 30 14 26 4...
Страница 265: ...0 5 32 38 7 DIN EN 12904 Steinbach 265 bg...
Страница 266: ...16A 30 mA RCD 266...
Страница 267: ...267 bg...
Страница 268: ...1 2 3 4 5 6 7 268...
Страница 269: ...FILTER FILTERN NACHSP LEN 20 30 R CKSP LEN Steinbach 2 0 3 0 6 bar GESCHLOSSEN ENTLEEREN WINTER 269 bg...
Страница 270: ...2 24 3 5 Active Balls Active Balls 1 5 4 2 4 3 O 20 4 32 5 4 6 7 8 O 18 1 5 4 20 32 19 18 28 21 270...
Страница 271: ...9 21 10 O 19 28 11 21 1 13 12 2 3 12 3 4 5 12 2 1 7 22 2 3 11 24 4 9 8 5 8 2 6 9 7 2 3 4 271 bg...
Страница 272: ...8 1 3 2 9 10 10 11 12 6 1 13 14 PUMP 15 7 5 6 7 8 272...
Страница 273: ...16 17 25 18 16 23 19 20 21 1 32 38 INTEX www steinbach group com 9 10 11 12 273 bg...
Страница 274: ...1 2 3 PH1 1 2 3 4 PH1 INTEX 1 INTEX INTEX 2 INTEX 14 A 1 13 14 15 274...
Страница 275: ...2 1 31 1 2 R CKSP LEN 3 2 WASTE 30 4 5 Active Balls Active Balls 3 31 1 1 2 5 5 2 3 275 bg...
Страница 277: ...9 9 8 10 11 12 13 4 12 5 C 1 3 2 3 4 5 6 7 8 31 1 9 WINTER 277 bg...
Страница 278: ...1 bar 278...
Страница 280: ...Classic 310 1 16 16 1 2 14 3 4 13 19 18 20 21 22 19 29 28 26 26 24 23 27 25 22 21 20 5 6 11 14 15 16 17 12 7 8 9 10 280...
Страница 282: ...Classic 400 1 17 17 1 2 3 4 13 19 18 20 21 22 19 29 28 26 26 24 23 27 25 22 21 20 5 6 11 14 15 16 17 12 7 8 9 10 282...