![SteelMax SM-D1 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/steelmax/sm-d1/sm-d1_operators-manual_1370072013.webp)
D1
- 13 -
D1 9/2011
Operators Manual for Drilling Machine
Uninstalling the cooling system:
a) Place the machine in the vertical position,
b) Raise the drive and the slide up by using the lever,
c) Remove the end of the cooling hose (2) on the connection end (4) in the reducer,
d) Remove the cooling system.
6. MAINTENANCE AND SERVICE
-
The D1 machine is equipped with a maintenance free system for
adjustment of guide slides.
-
Check condition of carbon brushes after every 100 hours of work.
Replacement of brushes is possible without removal of motor unit from the unit. (see
point 6.1) Other repair work should be done only by authorized service points,
appointed by distributor.
-
To prevent the machine from rusting (especially when used outdoors) all steel
parts should be covered with thin layer of grease film.
WARNING: The safety strap and web must be replaced after
every occurrence when machine came loose from steel and hung or
pulled on the strap and web.
If work piece thickness is less than 3/16” (5mm), the magnetic adhesion detection
system will not allow the motor to start. The same system will turn the motor OFF
after even a slight movement of the magnetic base.
Caution:
In the case that the machine falls on a hard surface,
from a height, is wet or is subjected to other unfortunate events that
could affect its technical state - work should be terminated
immediately and the machine should be sent to service for
inspection as soon as possible.