CONTROL BOX RE-INITIALIZATION:
•
In the event that a ‘Soft Reset’ does not restore normal operation, a ‘Hard
Reset’ may be required.
•
Currently, it is necessary to use a Digital / Preset Controller to perform this
operation.
•
To reset the Control Box to its factory settings:
1. Press memory positions
1
,
2
and the
up
button simultaneously for
10 seconds
2. Display shows
s5
3. Press the
up
button
4. Display shows
s7
5. Press the
up
button
6. Display shows
s0
7. Press ‘
Save
’; the unit is reset to factory settings
8. The display shows
E61
after factory reset. Soft reset the control box
(unplugging and replugging in the power cord)
9. Synchronize the lifting columns
SYNCHRONIZING / INITIALIZING LIFTING COLUMNS:
Note:
When legs are not synchronized, the desk will only move in the down
direction at a slower speed. Follow the steps below to synchronize the desk:
1. Operate the desk all the way down to the lowest position, and release the
down
button.
2. Press the
down
button again, and hold.
•
After a few seconds, the desk will visibly move up and down, settling to
its correct ‘bottom’ position.
•
The lifting columns are now synchronized via the software in the
control box.
3. Operate the desk all the way up and down to confirm proper function.
TESTING INDIVIDUAL LIFTING COLUMNS:
•
The control box is coded to operate only when all lifting columns are
properly connected. It is not possible to operate lifting columns individually
for troubleshooting purposes.
•
To properly identify faulty lifting columns, refer to step D of the
troubleshooting steps.
Note:
Contact your Steelcase dealer for troubleshooting assistance.