background image

                                                                                                 SD1200 - Sectional Garage Door Opener 

Page 2 

 

                            Installation & Operating Instructions 

V2.09/19

 

 

 

Important Safety Instructions

 

 
 

 

 

 

FAILURE TO COMPLY WITH THESE SAFETY RECOMMENDATIONS AND 
LOCAL  SAFETY  REGULATIONS  MAY  RESULT  IN  SERIOUS  INJURY, 
DEATH OR DAMAGE TO PROPERTY

 

PLEASE  READ  CAREFULLY  AND  ENSURE  THAT  ALL  SAFETY  RECOMMENDATIONS 
AND REGULATIONS ARE CONSIDERED AND ADHERED TO. 

 

 

 
 
 
 
 
 
 

 
 

 

This appliance is not intended for use by children or persons with reduced physical, sensory or mental 
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction 
by a person responsible for their safety. 

 

Do not wear watches, rings or loose clothing while installing or servicing a garage door opener. Ensure 
that gloves, safety goggles and suitable protective clothing is worn where appropriate. 

 

The opener must not be installed in a wet or damp space exposed to weather. 

 

The opener must not be used on a door with a wicket door (a door within a door). 

 

Keep garage door balanced. Do not let the opener compensate for a binding or sticking garage door. 
Binding, sticking or unbalanced doors must be repaired before installing this opener. 

 

To avoid serious personal injury from entanglement, remove all ropes, chains and locks connected to the 
garage door before installing the door opener. 

 

Installation and wiring must be in accordance with your local building and electrical codes. 

 

Install the wireless remote control (transmitter) in a location where the garage door is visible, at a height 
of no less than 1.5m and out of reach of children. Do not allow children to operate push buttons or 
transmitters. Serious personal injury from a closing garage door may result from misuse of the opener. 

 

Permanently fasten the Warning Labels in prominent places, adjacent to wall controls and on manual 
release cord as a reminder of safe operating procedures. 

 

Ensure that the safety reverse system is tested every month. The garage door must reverse on contact 
with a 40mm high object placed on the floor. Adjust if necessary and repeat test. Failure to adjust 
properly may result in serious personal injury from a closing garage door. 

 

Disconnect electric power to the door opener before making repairs. 

 

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly 
qualified persons in order to avoid hazard. 

 

Frequently examine the door installation paying particular attention to the cables, springs and mountings 
for signs of wear, damage or imbalance. Springs and hardware are under extreme tension and a fault 
can cause serious personal injury. Do not use if repair or adjustment is needed. 

 

Ensure that the opener is operated only when door is in full view, free of obstructions and the opener is 
properly adjusted. No one should enter or leave the garage while the door is in motion. 

 

Do not allow children to play near the door, or with door controls. Keep remotes away from children. 

 

The door may operate unexpectedly, therefore do not allow anything to stay in the path of the door. 

 

SAVE THESE INSTRUCTIONS- it is important for the safety of persons to follow all instructions.

 

 
An emergency key release must be installed if there is no pedestrian door or other access into the garage. 
 
 
 

 

Note: It is highly recommended that safety beams are included with all installations. Correctly installed safety 
beams will prevent the door from closing if a person or object is located within the door area. If the beam is 
broken during the door’s downward travel it will reverse back to the open position.  

This accessory must be used for all installations where the closing force is greater than 400N (40kg 
of force) as measured at the bottom of the door.

 

Содержание SD1200

Страница 1: ...19 SD1200 Sectional Garage Door Opener Installation and Operating Instructions THIS MANUAL CONTAINS IMPORTANT SAFETY INFORMATION DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THIS MANUAL THOROU...

Страница 2: ...tructions Safety beams or an equivalent safety device are recommended for any automated door for additional safety Standard Operation of the Door If the door is OPENING When the programmed remote cont...

Страница 3: ...s in prominent places adjacent to wall controls and on manual release cord as a reminder of safe operating procedures Ensure that the safety reverse system is tested every month The garage door must r...

Страница 4: ...A Up to 2500mm 3300mm 3000mm 3330mm Rail B Up to 3500mm 4300mm 4000mm 4330mm 14 13 12 10 9 8 5 7 6 4 2 1 15 11 1 SD1200 opener powerhead 2 Hand transmitter 2 3 Wall transmitter 4 Door bracket 5 Lintel...

Страница 5: ...clevis pin 15 and R clip 15 Slide fixing bracket onto rail at the drive end STEP 3 Adjust the belt tension by adjusting the nut located at the end of the rail assembly Always ensure that the trolley...

Страница 6: ...damage You may require help with this step if the door spring is in the way STEP 7 Disengage the trolley mechanism and slide back towards the powerhead securing the straight arm up into the rail asse...

Страница 7: ...closed insert the curved door arm 6 into the door bracket and secure with clevis pin 11 and R clip 11 With the trolley disengaged bring the straight arm and curved door arm together and secure using t...

Страница 8: ...ng Initiates programming modes saves the settings Button Up Open Opens the door Increases settings in programming mode Button Down Close Closes the door Decreases settings in programming mode LED Indi...

Страница 9: ...button to bring the door to the desired open position At this point you can make slight adjustments up and down until the door is in the desired position STEP 4 Press the P button once to save the op...

Страница 10: ...ain on indicating that the opener is now in normal operating mode Safety Reverse Test It is important that a safety reverse system test is carried out The garage door must reverse on contact with a 40...

Страница 11: ...lose force STEP 2 ADJUSTING THE CLOSE FORCE 1 Press and release the button to increase the force or button to decrease the force to the desired setting the numbers 1 to 8 indicate lowest to highest fo...

Страница 12: ...r will automatically return to standby mode Note A maximum of 10 codes can be learned by the opener If you want to program another transmitter and the memory is already full the first code will be del...

Страница 13: ...y do not obstruct the door movement see Fig 1 Ensure that the lenses are aligned One sensor is a sending sensor and one sensor is a receiving sensor Avoid positioning the sensors in direct sunlight as...

Страница 14: ...Press the P button once LED 6 starts flashing 4 Press the P button once LED 1 starts flashing 5 Press the P button once LED 8 starts flashing 6 Press the button once all LED lights turn off except LED...

Страница 15: ...until there is a long beep then release there will be three 3 beeps indicating the service counter has been set to 3 000 cycles After eight 8 seconds the cycle count will be saved and you can operate...

Страница 16: ...ensions Dimensions Powerhead 390mm L x 210mm W x 120mm H Length overall inc rail Rail A 3330mm Rail B 4330mm Weight Powerhead 5kg Safety Personal Push button stop in UP and DOWN direction Automatic sa...

Страница 17: ...utomatically reverses to the open position before closing completely If door is not correctly balanced call a garage door professional to correct the problem Re set the travel limits see pages 8 9 Inc...

Страница 18: ...nty period if you suspect the Product may be defective contact the retailer that you purchased the Product from or contact our technical support team and they will diagnose the issue and arrange for r...

Отзывы: