Safety Reversal Force Adjustment

 

 

 

 
 
 
 
 
 
 

 

The force, as measured at the bottom of the door, should not exceed 400N (40kgf). If this force is 
exceeded safety beams must be installed. 

 

STEP 1. ADJUSTING THE OPEN FORCE 

 

1)

 

Hold down “P” button for 6 seconds

 (LED 2 will begin flashing) 

2)

 

Press the “P” button twice

 (LED 6 will begin flashing) 

3)

 

Press and release the “+” button to increase the force or “

“ button to decrease the force to the 

desired setting

 (the numbers 1 to 8 indicate lowest to highest force setting) 

4)

 

Press the “P” button once to save

 (LED 1 will begin flashing to indicate the open force is now 

programmed and you are ready to adjust the close force) 

 

STEP 2. ADJUSTING THE CLOSE FORCE 

 

1)

 

Press 

and release the “+” button to increase the force or “

“ button to decrease the force to the 

desired setting

 (the numbers 1 to 8 indicate lowest to highest force setting) 

2)

 

Press the “P” button once to save

 (LED 3 will remain on indicating the close force is now 

programmed) 

 
 
 
 
 
 

 
 
 
 
 
 

ener

 

 

 

 
 
 
 
 
 
 
 

 
 

 

CAUTION

- Force settings are 

automatically 

set during the programming phase, 

after travel limit setting procedure on pages 8-9. 

 

Too much force will cause improper operation of the safety reversal mechanism and 
may cause serious injury. The higher the force is set the less sensitive the opener is 
to detecting an obstruction. 

 

Force settings should only be adjusted by a suitable qualified technician.  

 

OPENER FORCE IS NOW SET 

 

The safety reversal system must now be tested by placing a 40mm high 
object on the floor and ensuring the door reverses on contact, see page 9. 
Adjust force again if necessary. 

Содержание SD1200

Страница 1: ...19 SD1200 Sectional Garage Door Opener Installation and Operating Instructions THIS MANUAL CONTAINS IMPORTANT SAFETY INFORMATION DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THIS MANUAL THOROU...

Страница 2: ...tructions Safety beams or an equivalent safety device are recommended for any automated door for additional safety Standard Operation of the Door If the door is OPENING When the programmed remote cont...

Страница 3: ...s in prominent places adjacent to wall controls and on manual release cord as a reminder of safe operating procedures Ensure that the safety reverse system is tested every month The garage door must r...

Страница 4: ...A Up to 2500mm 3300mm 3000mm 3330mm Rail B Up to 3500mm 4300mm 4000mm 4330mm 14 13 12 10 9 8 5 7 6 4 2 1 15 11 1 SD1200 opener powerhead 2 Hand transmitter 2 3 Wall transmitter 4 Door bracket 5 Lintel...

Страница 5: ...clevis pin 15 and R clip 15 Slide fixing bracket onto rail at the drive end STEP 3 Adjust the belt tension by adjusting the nut located at the end of the rail assembly Always ensure that the trolley...

Страница 6: ...damage You may require help with this step if the door spring is in the way STEP 7 Disengage the trolley mechanism and slide back towards the powerhead securing the straight arm up into the rail asse...

Страница 7: ...closed insert the curved door arm 6 into the door bracket and secure with clevis pin 11 and R clip 11 With the trolley disengaged bring the straight arm and curved door arm together and secure using t...

Страница 8: ...ng Initiates programming modes saves the settings Button Up Open Opens the door Increases settings in programming mode Button Down Close Closes the door Decreases settings in programming mode LED Indi...

Страница 9: ...button to bring the door to the desired open position At this point you can make slight adjustments up and down until the door is in the desired position STEP 4 Press the P button once to save the op...

Страница 10: ...ain on indicating that the opener is now in normal operating mode Safety Reverse Test It is important that a safety reverse system test is carried out The garage door must reverse on contact with a 40...

Страница 11: ...lose force STEP 2 ADJUSTING THE CLOSE FORCE 1 Press and release the button to increase the force or button to decrease the force to the desired setting the numbers 1 to 8 indicate lowest to highest fo...

Страница 12: ...r will automatically return to standby mode Note A maximum of 10 codes can be learned by the opener If you want to program another transmitter and the memory is already full the first code will be del...

Страница 13: ...y do not obstruct the door movement see Fig 1 Ensure that the lenses are aligned One sensor is a sending sensor and one sensor is a receiving sensor Avoid positioning the sensors in direct sunlight as...

Страница 14: ...Press the P button once LED 6 starts flashing 4 Press the P button once LED 1 starts flashing 5 Press the P button once LED 8 starts flashing 6 Press the button once all LED lights turn off except LED...

Страница 15: ...until there is a long beep then release there will be three 3 beeps indicating the service counter has been set to 3 000 cycles After eight 8 seconds the cycle count will be saved and you can operate...

Страница 16: ...ensions Dimensions Powerhead 390mm L x 210mm W x 120mm H Length overall inc rail Rail A 3330mm Rail B 4330mm Weight Powerhead 5kg Safety Personal Push button stop in UP and DOWN direction Automatic sa...

Страница 17: ...utomatically reverses to the open position before closing completely If door is not correctly balanced call a garage door professional to correct the problem Re set the travel limits see pages 8 9 Inc...

Страница 18: ...nty period if you suspect the Product may be defective contact the retailer that you purchased the Product from or contact our technical support team and they will diagnose the issue and arrange for r...

Отзывы: