7 Technical data
StecaGrid 2010+ D
Master
StecaGrid 2010+
Master
StecaGrid 2010+
Slave
DC input side (PV-generator)
Maximum start voltage
410 V
Maximum input voltage (V
dcmax
)
450 V (higher voltages can damage the device)
Minimum input voltage (V
dcmin
)
80 V
Start-up input voltage (V
dcstart
)
50 V
Rated input voltage (V
dc,r
)
300 V
Minimum input voltage for rated output
13 V
MPP voltage (V
mppmin
… V
mppmax
)
80 V … 400 V
Maximum input current (I
dcmax
)
x 8 A [current limited by inverter] or 1 x 16 A [parallel inputs]
Rated input current
7 A
Maximum input power
1,075 W [per input] or ,150 W [ parallel inputs]
Rated input power
1,075 W [per input] or ,150 W [ parallel inputs]
Maximum recommended PV power
,400 Wp
Grounding
internal function grounding of the negative input for connecting amorphous and micromorphic thin-
film modules
Derating / limiting
automatic when
- input power is higher (> 1,075 W / input)
- the device is not cooled sufficiently
- input currents > x 8 A or 1 x 16 A (parallel inputs)
(higher currents are limited by the equipment and therefore will not damage the inverter)
AC output side (Grid connection)
Grid voltage (V
acmin
… V
acmax
)
190 V ... 65 V [depending on regional settings]
Rated grid voltage (V
ac,r
)
30 V
Maximum output current (I
acmax
)
10 A
Rated output current
8.7 A at 30 V
Maximum output power
,000 W
Rated power (P
ac,r
)
,000 W
Rated frequency (f
r
)
50 Hz
Grid type
L / N + PE
Frequency (f
min
… f
max
)
47.5 Hz ... 5 Hz [depending on regional settings]
Night-time power loss
1.3 W
1.0 W
0 W
Feeding phases
single-phase
Power factor
> 0.95
Distortion factor
< 5 % (max. power)
Disconnection value during stand-alone operation
[See table of countries (enclosed)]
Characterisation of the operating performance
Maximum efficiency
95 %
European efficiency (
η
EU
)
93.3 %
93.5 %
MPP efficiency
> 99 %
Operating efficiency (at 5 %, 10 %, 0 %, 5 %, 30 %, 50 %,
75 %, 100 % of rated power)
78.8 %, 86.8 %, 91.7 %, 9.6 %,
93.3 %, 94.4 %, 94,7 %, 95.0 %
78.8 %, 86.8 %, 91.7 %, 9.6 %,
93.3 %, 94.4 %, 94,7 %, 95.0 %
80. %, 87.5 %, 9.0 %, 9.9 %,
93.5 %, 94.6 %, 94,9 %, 95.1 %
Efficiency reduction in the case of a rise in ambient temperature
(with temperatures > 40 °C)
% / °C
Efficiency reduction in the case of deviation from the DC rated
voltage
0.006 % / V
Power derating at full power
from 40 °C (Tamb)
Switch-on power
0 W
Shut-down power
18 W
Standby power
3 W
Safety
Protection class
I
Isolation principle
HF-transformer with galvanic separation and amplified isolation
Grid monitoring
MSD, compliant with DIN VDE
016-1-1
see table of countries
via master
Isolation monitoring
none, because of galvanic isolation through the HF transformer in the device
Thermal monitoring
yes
Wrong polarity protection
yes
Safety directive
EN 6103 (EN 50178) and IEC 60950*
Operating conditions
Electromagnetic compatibility (EMC)
EN 61000-6-3 (EN 55014 and EN 550 class B)
EN 61000-6-
Service category
exterior
Area of application
indoor rooms with or without air conditioning, outdoors with or without protection
Rate of pollution
II