O P E R A T I O N & S E R V I C E
6. If temperature is Ok and that there is no water in hose, you can open the fill & drain hose
connector located below the cylinder, to do so:
◦
Push on button and pull on the flexible hose on right side of the connector.
◦
Once open, you can tilt the cylinder to have some more remaining water dripping in the
bottom pan
7. You can now proceed to remove the cylinder
◦
Remove the safety pin securing the latch
◦
Open the latch
8. You can now disengage the cylinder from the back support and remove the cylinder.
9. You can dispose of the scale flakes accumulated at the bottom of the cylinder
Risk of damage.
Do not use chemical nor scraping with any metal tool to remove scale
from cylinder, heating element of temperature sensor surface.
10. If the use use of plastic brush or clean cloth is not enough to remove the scale from surface and
that scale deposit is more than 15mm thick, you can use a solution of muriatic acid at 10% (1 to
10) dilution with cold water or white vinegar.
In case of use of acidic solution or white vinegar
do not spray
such solution.
Best results are obtained by pouring cylinder with this solution and letting it rest for few hours.
11. A full and throughout clear water rinsing is required before to re-assemble the cylinder and to
put
steamOres
humidifier back in operation.
Ensure that drain port and hose is not blocked by scale or debris.
12. Proceed to re-assembly with same above steps in reverse order.
◦
Make sure that the cylinder is properly engaged and secured.
◦
Re-install the safety pin on latch to prevent from any unintentional cylinder opening.
◦
Reconnect Fill & Drain connector
13. Re-connect
steamOres
humidifier to power supply it will re-start automatically.
26