Remove the access cover(s), then remove the foam 

4. 

insulation block. 

Remove the protective plastic cover(s) over the 

5. 

elements from their attachment point.  
Disconnect the electrical wires from the heating 

6. 

element(s) by loosening the screws (Figure 12). 

Remove the screw-in element(s) by turning the 

element(s) counterclockwise with a 1-1/2 inch socket 

wrench. Remove the existing gasket(s).

Clean the area where the gasket(s) fits to the tank 

7. 

and internal threads. If you are replacing the bottom 

element, remove any accumulated sediment on the 

bottom of the tank.
Make sure the replacement element(s) has the correct  

8. 

voltage and wattage rating by matching it to the rating 

plate on the water heater. Position the new gasket(s)  

on the element and insert it into the water heater   tank 

(Figure 13). 

NOTE:

 Apply a light coat of hand dishwashing soap 

and water to the gasket. Tighten the element by turning 

it clockwise until secure.
Close the drain valve and open the nearest hot water  

9. 

faucet. 

Then open the cold water shut off valve

 and 

allow the tank to fill completely with water.  To purge 

the lines of any excess air and sediment, keep the hot 

water faucet open for 3 minutes after a constant flow of 

water is obtained.

Check for leaks around the element(s).

10. 

Reconnect the electrical wires to the element and 

11. 

securely tighten the screws (See Figure 12).
Replace the 

12. 

protective plastic cover(s) removed earlier. 

Make sure the cover(s) are securely engaged on the 

attachment point(s).
Replace the foam block(s) and access cover(s).

13. 

Although this water heater is equipped with “Dry Fire” 

14. 

protection circuitry, be sure tank is completely filled with 

water before applying electrical power to the water heater.

Reconnect electrical power to the water heater at the 

15. 

circuit breaker/fuse box.

Press the power button to turn the water heater on. Set 

16. 

the desired water temperature and operating mode. 

NOTE:

 The water heater will conduct a system 

diagnostic (approximately 8 minutes) prior to operation. 

Screws

Wires

Element

Figure 12:

Screw-in
Element

Figure 13:

Gasket

Spud

Routine Preventive Maintenance

At least monthly, a visual inspection should be made of the 

following:

Air Filter (Remove and inspect, clean if needed, and 

• 

reinstall).
Condensate drain pan and condensate lines.

• 

The lower metal drain pan for standing water which may 

• 

indicate a clogged condensate drain pan, condensate 

lines, or plumbing leak.
Leaking or damaged water piping.

• 

Presence of corrosive materials in the installation area.

• 

Presence of combustible materials near the water heater.

• 

After servicing this water heater, check to make sure it 

• 

is working properly. (See “Operating Your Water Heater” 

section of this manual.)

IMPORTANT:

 If you lack the necessary skills required to 

properly perform this visual inspection, you should not 

proceed, but get help from a qualified person.

Cleaning the Heat Pump

Air Filter Cleaning/Replacement

IMPORTANT:

 Before attempting to clean or replace the air 

fi

 lter press the power button to place the water heater in 

Standby Mode and turn-off power to the water heater at the 
circuit breaker/fuse box.

Locate the screw securing the filter panel to the heat 

1. 

pump shroud and loosening it.
Remove (slide) the filter from the unit.

2. 

If you are replacing the filter skip to step 4. To clean the 

3. 

filter use a vacuum with a hose attachment to remove 

any dust or debris.
Place the new or cleaned filter into the water heater 

4. 

and secure the filter to the shroud with the screw 

loosened earlier. 

NOTE:

 The guides/slots when inserting the filter into 

the water heater. 
Restore power to the water heater and press the 

5. 

power button to turn the water heater on. 

NOTE:

 the 

water heater will conduct a system diagnostic prior to 

operation. 

Inspection/Cleaning of the Condensate 
Drain Pan & Condensate Drain Lines

IMPORTANT:

 Before attempting to clean or replace the 

condensate drain pan or lines press the power button to 
place the water heater in Standby Mode and shut-off power 
to the water heater at the circuit breaker/fuse box.

Remove the access panel (fan side) by loosening the 

1. 

screws securing it to the unit. 
Check the condensate drain pan and drain lines for any 

2. 

dirt or debris that might interfere with proper drainage. 

Wipe out any dirt or debris with a damp cloth.
Once the condensate drain pan and lines have been 

3. 

inspected/cleaned, secure the access panel to the water 

heater.
Restore power to the water heater and press the power 

4. 

button to turn the water heater on. 

NOTE:

 The water heater will conduct a system diagnostic 

prior to operation. 

Содержание 318258-000

Страница 1: ...Information 3 Consumer Responsibilities 3 Unpacking Instructions 3 4 Location Requirements 4 Water System Piping 5 6 Temperature Pressure Relief Valve 7 8 Electrical Requirements 8 9 Installation Checklist 10 Operating Your Water Heater 11 13 Before Using 11 Water Temperature Regulation 11 Adjusting the User Interface Module Operational Mode 12 Operational Conditions 13 Maintenance of Your Water H...

Страница 2: ...s extremely flammable To reduce the risk of injury under these conditions it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system When hydrogen is present there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow There should be no smoking or...

Страница 3: ...eipt as proof of purchase Basic Operation Fundamentals The Heat Pump Water Heater HPWH is an integrated heat pump water heater unit having an 850 watt compressor and external coil heat exchanger with backup electric elements See Figure 1 When in Efficiency Mode the heat pump draws heat from the ambient air in the room and transfers it to the water in the tank through the coil heat exchanger While ...

Страница 4: ...read all instructions before attempting to assemble and install this product After installation dispose of recycle all packaging materials Location Requirements Site location Select a location near the center of the water piping system The unit must be installed indoors and in a vertical position on a level surface The flooring beneath the water heater must be able to support the weight of the wat...

Страница 5: ...hown in Figure 4 If installing the water heater in a closed water system 5 install an expansion tank in the cold water line as specified under Closed System Thermal Expansion Install a shut off valve in the cold water inlet line It 6 should be located close to the water heater and be easily accessible Know the location of this valve and how to shut off the water to the heater Install a discharge l...

Страница 6: ...des Use appropriate primer and glue to cement the condensate drain lines to the heat pump drain pan NOTE The heat pump drain pan is ABS and the two condensate drain pipes should be PVC If a condensate pump is installed it should shut off the heat pump in the event the condensate pump fails or the float switch in the pump activates See Condensate Pump Installation section Closed System Thermal Expa...

Страница 7: ...lve and the end of the discharge line Shall terminate a maximum of six inches above a floor drain or external to the building In cold climates it is recommended that the discharge pipe be terminated at an adequate drain inside the building Shall be of material listed for hot water distribution Shall be installed to allow complete drainage of both the valve and discharge line Temperature Pressure R...

Страница 8: ...lled with water and all air is purged from the tank before making any electrical connections See Draining and Flushing Section Turn off power to the electrical wiring for the water heater at 2 the circuit breaker fuse box Remove the left louvered access panel when facing the 3 water heater by loosening the screws securing it to the water heater Loosen the screws securing the electrical junction bo...

Страница 9: ...7 Press the power button to turn the water heater on 8 and select the desired operational mode After about 8 minutes the heat pump will turn on Test the operation of the shut off switch by unplugging 9 the condensate pump and filling the condensate reservoir with water until the float switch opens the circuit The heat pump should turn off and the error code 10 CONDENSATE DRAIN ALARM will appear on...

Страница 10: ... free of leaks Heater completely filled with water See Water Piping System section Closed system pressure buildup precautions installed See Closed System Thermal Expansion section Mixing valve when applicable installed per manufacturer s instructions See Water Temperature Regulation section INSTALLATION CHECKLIST Condensate Drain Line Installation Must be located with access to an adequate drain o...

Страница 11: ...hing in the red reset button located on the ECO block If the ECO continues to shut off the water heater contact a qualified person for service Water Temperature Regulation Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at highest risk of being scalded Feel water before bathing or showering Temperature limiting valves are availab...

Страница 12: ... the User Interface are touch sensitive and require only a light touch to actuate EFFICIENCY Efficiency Mode Is the most energy efficient mode This mode uses the heat pump to heat water in the tank The elements are not used unless the ambient operating temperature is below 45 F or above 109 F If hot water demands are not met in Efficiency Mode it may be necessary to switch to Hybrid Mode HYBRID Hy...

Страница 13: ...ard These noises are common and may result from the following Normal expansion and contraction of metal parts 1 during periods of heat up and cool down Sediment buildup on or around the elements could 2 create varying amounts of noise and may cause premature tank failure Drain and flush the tank as directed under the Draining and Flushing section The heat pump compressor or fan running 3 Stacking ...

Страница 14: ...PORTANT Do not turn on power to the water heater unless it is completely filled with water To ensure that the tank is full open a hot water faucet and allow the water to run until the air is purged and the water flows uninterrupted from the faucet Press the power button to turn the water heater on 8 NOTE The water heater will conduct a system diagnostic prior to operation If the water heater is go...

Страница 15: ...Air Filter Remove and inspect clean if needed and reinstall Condensate drain pan and condensate lines The lower metal drain pan for standing water which may indicate a clogged condensate drain pan condensate lines or plumbing leak Leaking or damaged water piping Presence of corrosive materials in the installation area Presence of combustible materials near the water heater After servicing this wat...

Страница 16: ... OPEN OR AD ERROR 1 Upper Temperature Sensor is not functioning Contact a qualified person to service the unit 1 LOWER TEMP SENSOR SHORT OR OPEN OR AD ERROR 1 Lower Temperature Sensor is not functioning Contact a qualified person to service the unit 1 DISCHARGE TEMP SENSOR SHORT OR OPEN OR AD ERROR 1 Discharge Temperature Sensor is not functioning Contact a qualified person to service the unit 1 C...

Страница 17: ...n is at the top Insulate exposed piping 5 Repair hot water leaks 6 Call qualified person for service 7 Drain and flush tank Water conditioning may 8 be necessary to minimize build up HIGH OPERATION COSTS Temperature set point too high 1 Air filter dirty 2 Electric mode selected 3 Water connections to unit reversed 4 Heat lost thru long run of exposed 5 pipe Hot water leak at faucet or piping 6 Sed...

Страница 18: ...14 Drain Valve 15 Protective Plastic Cover 16 ECO Cover 17 Control Board 18 Relay 19 EPS Cover 20 Ambient Coil Discharge Temperature Sensor 21 Upper Lower Tank Temperature Sensor 22 Run Capacitor 23 Control Board Module Fuses REPAIR PARTS Repair parts may be ordered through your plumber local distributor home improvement center or by calling 1 800 365 0024 When ordering repair parts always give th...