Water Heater Location

Centrally located with the water piping system.

 

The 

fl

 ooring beneath the water heater must be able to 

 

support the weight of the water heater when 

fi

 lled with 

water (967 lbs. full).

Located indoors (such as a basement or garage) 

 

and in a vertical position. Sheltered from freezing 
temperatures.
Provisions made to shelter the area from water    

 

damage. Metal drain pan installed and piped to an 
adequate drain.
Sufficient room to service the water heater.

 

Sufficient air for the heat pump to function. 

 

The water 

heater must be located in a space 750 cubic feet or 
larger, and must have unrestricted air

fl

 ow.  As an 

example, a room that has an 8 foot tall ceiling and is 
10 feet long by 9-1/2 feet wide would contain 760 cubic 
feet. 

 

NOTE:

 For optimal ef

fi

 ciency and serviceability, the 

following clearances should be maintained: 3 feet on 
the air inlet side, 5 feet on the air outlet side, 6 inches in 
the back, and 2 feet in the front.

 

The unit cannot be placed into any type of closet or 

 

small enclosure.
The site location must be free from any corrosive 

 

elements in the atmosphere such as sulfur, 

fl

 uorine, 

and chlorine. These elements are found in aerosol 
sprays, detergents, bleaches, cleaning solvents, air 
fresheners, paint, and varnish removers, refrigerants, 
and many other commercial and household products. 
In addition excessive dust and lint may affect the 
operation of the unit and require more frequent 
cleaning (See “Cleaning the Heat Pump” section).
Ambient air temperature must be above 45°F and 

 

below 109°F. If the ambient air temperature falls 
outside these upper and lower limits the electrical 
elements will activate to meet the hot water demand.

Water System Piping

Temperature and pressure relief valve properly    

 

installed with a discharge pipe run to an adequate drain  
and sheltered from freezing (See Figure 5).
All piping properly installed and free of leaks.

 

Heater completely filled with water (See “Water Piping 

 

System” section).
Closed system pressure buildup precautions installed 

 

(See “Closed System/Thermal Expansion” section).
Mixing valve (when applicable) installed per 

 

manufacturer’s instructions (See “Water Temperature 
Regulation” section).

INSTALLATION CHECKLIST

Condensate Drain Line Installation

Must be located with access to an adequate drain or 

 

condensate pump.
Condensate drain lines installed and piped to an 

 

adequate drain or condensate pump (See Figure 4).

Electrical Connections

The water heater requires 240 VAC for proper 

 

operation.
Wiring size and connections comply with all applicable  

 

codes or in the absence of local or state codes follow 
NFPA-70, the National Electrical Code-current edition.
Water heater and electrical supply are properly    

 

grounded.
Wiring enclosed in approved conduit (if required by 

 

local codes).

Proper overload fuse or circuit breaker protection 

 

installed.

Post Installation Review

Understand how to use the User Interface Module to 

 

set the various modes and functions (See “Adjusting 
the User Interface Module/Operating Modes” section). 
Hybrid Mode is the recommended Operating Mode. 

 

Understand the various Operating Modes and which 
mode may be best based on season, ambient 
temperature, and usage (See “Operating Mode 
Description” section). 

NOTE:

 It may be necessary to temporarily change 

modes if for example filling a spa or hot tub.
Understand the importance of routine inspection/

 

maintenance of the condensate drain pan and lines 
(See “

Inspection/Cleaning of the Condensate Drain 

Pan & Condensate Drain Lines” section)

.  This is to 

help prevent any possible drain line blockage resulting 
in the condensate drain pan overflowing. 

IMPORTANT:

 Water coming from the plastic shroud is 

an indicator that both condensation drain lines may be 
blocked. Immediate action is required.
To maintain optimal operation check, remove and clean 

 

the air filter (See “Air Filter Cleaning/Replacement” 
section).
The Installation Instructions and Use & Care Guide 

 

should be kept with the water heater for reference. 

Содержание 318258-000

Страница 1: ...Information 3 Consumer Responsibilities 3 Unpacking Instructions 3 4 Location Requirements 4 Water System Piping 5 6 Temperature Pressure Relief Valve 7 8 Electrical Requirements 8 9 Installation Checklist 10 Operating Your Water Heater 11 13 Before Using 11 Water Temperature Regulation 11 Adjusting the User Interface Module Operational Mode 12 Operational Conditions 13 Maintenance of Your Water H...

Страница 2: ...s extremely flammable To reduce the risk of injury under these conditions it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system When hydrogen is present there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow There should be no smoking or...

Страница 3: ...eipt as proof of purchase Basic Operation Fundamentals The Heat Pump Water Heater HPWH is an integrated heat pump water heater unit having an 850 watt compressor and external coil heat exchanger with backup electric elements See Figure 1 When in Efficiency Mode the heat pump draws heat from the ambient air in the room and transfers it to the water in the tank through the coil heat exchanger While ...

Страница 4: ...read all instructions before attempting to assemble and install this product After installation dispose of recycle all packaging materials Location Requirements Site location Select a location near the center of the water piping system The unit must be installed indoors and in a vertical position on a level surface The flooring beneath the water heater must be able to support the weight of the wat...

Страница 5: ...hown in Figure 4 If installing the water heater in a closed water system 5 install an expansion tank in the cold water line as specified under Closed System Thermal Expansion Install a shut off valve in the cold water inlet line It 6 should be located close to the water heater and be easily accessible Know the location of this valve and how to shut off the water to the heater Install a discharge l...

Страница 6: ...des Use appropriate primer and glue to cement the condensate drain lines to the heat pump drain pan NOTE The heat pump drain pan is ABS and the two condensate drain pipes should be PVC If a condensate pump is installed it should shut off the heat pump in the event the condensate pump fails or the float switch in the pump activates See Condensate Pump Installation section Closed System Thermal Expa...

Страница 7: ...lve and the end of the discharge line Shall terminate a maximum of six inches above a floor drain or external to the building In cold climates it is recommended that the discharge pipe be terminated at an adequate drain inside the building Shall be of material listed for hot water distribution Shall be installed to allow complete drainage of both the valve and discharge line Temperature Pressure R...

Страница 8: ...lled with water and all air is purged from the tank before making any electrical connections See Draining and Flushing Section Turn off power to the electrical wiring for the water heater at 2 the circuit breaker fuse box Remove the left louvered access panel when facing the 3 water heater by loosening the screws securing it to the water heater Loosen the screws securing the electrical junction bo...

Страница 9: ...7 Press the power button to turn the water heater on 8 and select the desired operational mode After about 8 minutes the heat pump will turn on Test the operation of the shut off switch by unplugging 9 the condensate pump and filling the condensate reservoir with water until the float switch opens the circuit The heat pump should turn off and the error code 10 CONDENSATE DRAIN ALARM will appear on...

Страница 10: ... free of leaks Heater completely filled with water See Water Piping System section Closed system pressure buildup precautions installed See Closed System Thermal Expansion section Mixing valve when applicable installed per manufacturer s instructions See Water Temperature Regulation section INSTALLATION CHECKLIST Condensate Drain Line Installation Must be located with access to an adequate drain o...

Страница 11: ...hing in the red reset button located on the ECO block If the ECO continues to shut off the water heater contact a qualified person for service Water Temperature Regulation Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at highest risk of being scalded Feel water before bathing or showering Temperature limiting valves are availab...

Страница 12: ... the User Interface are touch sensitive and require only a light touch to actuate EFFICIENCY Efficiency Mode Is the most energy efficient mode This mode uses the heat pump to heat water in the tank The elements are not used unless the ambient operating temperature is below 45 F or above 109 F If hot water demands are not met in Efficiency Mode it may be necessary to switch to Hybrid Mode HYBRID Hy...

Страница 13: ...ard These noises are common and may result from the following Normal expansion and contraction of metal parts 1 during periods of heat up and cool down Sediment buildup on or around the elements could 2 create varying amounts of noise and may cause premature tank failure Drain and flush the tank as directed under the Draining and Flushing section The heat pump compressor or fan running 3 Stacking ...

Страница 14: ...PORTANT Do not turn on power to the water heater unless it is completely filled with water To ensure that the tank is full open a hot water faucet and allow the water to run until the air is purged and the water flows uninterrupted from the faucet Press the power button to turn the water heater on 8 NOTE The water heater will conduct a system diagnostic prior to operation If the water heater is go...

Страница 15: ...Air Filter Remove and inspect clean if needed and reinstall Condensate drain pan and condensate lines The lower metal drain pan for standing water which may indicate a clogged condensate drain pan condensate lines or plumbing leak Leaking or damaged water piping Presence of corrosive materials in the installation area Presence of combustible materials near the water heater After servicing this wat...

Страница 16: ... OPEN OR AD ERROR 1 Upper Temperature Sensor is not functioning Contact a qualified person to service the unit 1 LOWER TEMP SENSOR SHORT OR OPEN OR AD ERROR 1 Lower Temperature Sensor is not functioning Contact a qualified person to service the unit 1 DISCHARGE TEMP SENSOR SHORT OR OPEN OR AD ERROR 1 Discharge Temperature Sensor is not functioning Contact a qualified person to service the unit 1 C...

Страница 17: ...n is at the top Insulate exposed piping 5 Repair hot water leaks 6 Call qualified person for service 7 Drain and flush tank Water conditioning may 8 be necessary to minimize build up HIGH OPERATION COSTS Temperature set point too high 1 Air filter dirty 2 Electric mode selected 3 Water connections to unit reversed 4 Heat lost thru long run of exposed 5 pipe Hot water leak at faucet or piping 6 Sed...

Страница 18: ...14 Drain Valve 15 Protective Plastic Cover 16 ECO Cover 17 Control Board 18 Relay 19 EPS Cover 20 Ambient Coil Discharge Temperature Sensor 21 Upper Lower Tank Temperature Sensor 22 Run Capacitor 23 Control Board Module Fuses REPAIR PARTS Repair parts may be ordered through your plumber local distributor home improvement center or by calling 1 800 365 0024 When ordering repair parts always give th...

Страница 19: ...19 NOTES ...

Страница 20: ...20 Copyright 2010 State Industries Inc All rights reserved ...

Отзывы: