background image

O P E R A T I O N S   M A N U A L

Standard Charger 
& Custom Charger

Содержание Custom Charger

Страница 1: ...O P E R AT I O N S M A N U A L Standard Charger Custom Charger ...

Страница 2: ...de 11 Regulatory Information Safety Information 13 FCC Information 16 The Standard Charger is designed to be a portable charger for standard style lithium ion rechargeable hearing aids The Custom Charger is designed to be a portable charger for custom style lithium ion rechargeable hearing aids Both chargers work when plugged into a wall or on the go with an on board battery that will charge a pai...

Страница 3: ...3 2 1 6 7 Features Controls and Identification 1 Desiccant puck holder 2 Cleaning brush 3 Earbud earmold reservoir 4 Charging ports posts 5 Hearing aid charging LEDs 6 On board battery LEDs 7 Power supply port Standard charger only 5 5 3 2 4 4 ...

Страница 4: ...harging occurs with the lid open or closed Hearing aids will be fully charged in under 3 hours It is safe to store hearing aids in the charger after they are fully charged and any time that you are not wearing them Hearing aids will automatically power on when removed from the charger To illuminate LEDs when the charger is not plugged in remove a hearing aid from its charging port post for three s...

Страница 5: ...in 4 Solid 75 3 Solid 75 2 Solid 50 1 Solid 25 1 Blinking Charge Low Power On Off ON The hearing aids will power on automatically after removing them from the charger There is a delay that allows you time to insert your hearing aid into your ear ON If the hearing aid is manually powered off pressing the user control for three seconds will power it on The delay exists to give you time to insert the...

Страница 6: ...harging hearing aids no LEDs are illuminated On board battery save mode To illuminate LEDs remove hearing aid from its charging port post for three seconds then reinsert it LEDs will remain illuminated for 10 seconds Troubleshooting 11 Charger Care Keep your charger clean Heat moisture and foreign materials can result in poor performance Using the provided cleaning brush keep the charging ports po...

Страница 7: ...terference caused by power line disturbances airport metal detectors electromagnetic fields from other medical devices radio signals and electrostatic discharges If you use other medical devices or wear implantable medical devices such as defibrillators or pacemakers and are concerned that your hearing aids might cause interference with your medical device please contact your physician or the manu...

Страница 8: ...sions and immunity tests IEC 60601 1 2 radiated and conducted emissions requirements for a Group 1 Class B device as stated in CISPR 11 Harmonic distortion and voltage fluctuations affecting the power input source as stated in Table 2 of IEC 60601 1 2 RF radiated immunity at a field level of 10 V m between 80 MHz and 2 7 GHz as well as higher field levels from communications devices as stated in T...

Страница 9: ... follow one of two options Option 1 Insert pry bars between the plastic and the microUSB metal housing top and bottom Pry apart to break the seam Clip battery wires and dispose battery Option 2 Using the style groove as a guide sever the plastic case on all 4 sides with a dremel blade ultrasonic knife hot wire or band saw blade In each case establish a limit guide so entrance over 3 32 inch beyond...

Страница 10: ...Notes Notes ...

Страница 11: ... 2019 Starkey All Rights Reserved 86375 007 12 19 BKLT3089 00 EE SG The Starkey logo and Starkey Hearing Technologies are trademarks of Starkey Laboratories Inc ...

Отзывы: