Regulatory Information | 15
14 | Regulatory Information
We are required by regulations to provide the following warnings:
WARNING:
Use of wireless hearing aids or charger directly next to other
electronic equipment should be avoided because it could result in improper
performance. If such use is necessary, note as to whether your hearing aids and
the other equipment are operating normally.
WARNING:
Use of accessories, components or replacement parts other than
those provided by the manufacturer of your hearing aids or charger could result
in increased electromagnetic emissions and decreased electromagnetic immunity
and could result in degradation of performance.
WARNING:
If Portable Radio Frequency communications equipment is used
closer than 30 cm (12 inches) from your hearing aid or charger, degradation of
the performance of your hearing aid or charger could result. If this occurs, move
away from the communications equipment.
DO NOT OPEN HEARING AID OR CHARGER,
NO USER-SERVICEABLE PARTS INSIDE
The Standard Charger and Custom Charger have a rating of IP 5X per IEC 60529.
This means that the chargers are protected from dust.
The service life of both the Standard Charger and Custom Charger is 3 years.
The Standard Charger and Custom Charger have been tested to, and have
passed, the following emissions and immunity tests:
• IEC 60601-1-2 radiated and conducted emissions requirements for a Group 1
Class B device as stated in CISPR 11.
• Harmonic distortion and voltage fluctuations affecting the power input source
as stated in Table 2 of IEC 60601-1-2.
• RF radiated immunity at a field level of 10 V/m between 80 MHz and 2.7 GHz
as well as higher field levels from communications devices as stated in Table 9
of IEC 60601-1-2.
• Immunity to power frequency magnetic fields at a field level of 30 A/m.
• Immunity to ESD levels of +/- 8 kV conducted discharge and +/- 15 kV air
discharge.
• Immunity to Electrical fast transients on the power input at a level of +/- 2 kV at
a 100 Hz repetition rate.
• Immunity to Surges on the power input of +/- 1 kV line to line.
• Immunity to conducted disturbances induced by RF fields on the power input
as stated in Table 6 of IEC 60601-1-2.
• Immunity to voltage dips and interruptions on the power input as stated in
Table 6 of IEC 60601-1-2.
FCC NOTICE
These devices comply with part 15 of the FCC rules and with ISED Canada
license-exempt RSS standards. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause
undesired operation of the device.
Note: The manufacturer is not responsible for any radio or TV interference caused
by unauthorized modifications to this equipment. Such modifications could void
the user’s authority to operate the equipment.
Содержание Custom Charger
Страница 1: ...O P E R AT I O N S M A N U A L Standard Charger Custom Charger ...
Страница 10: ...Notes Notes ...