SF-HC25C3 Height Controller
17
parameter is careful, the Settings may cause shock, set the range 0 to 20.
P17: the time of the impact of the collision, the time of lifting after the stop state
cutting moment impact plate, 0 does not use this function, the unit: seconds, the
setting range is 0~ 10.
P18: arc rolling into time, when the block to the plasma power source signal and
the arc after waiting for a period of time to detect arc pressure, to avoid the
punch when unstable voltage, can be understood as rev arc delay, as part of the
unit: second, setting the range of 0 ~ 10.
P19: start up time, prevent the pan from scraping to the cutting gun, when
starting up, you can set a lift distance, 0 do not use this function, the unit:
seconds, set range 0~ 10.
P20: the time of the arc raising gun, after cutting completion, raise a distance to
prevent the scraping gun, 0 do not use this function, the unit: seconds, set the
range of 0~ 10.
P21: dynamic perforation rise time, set this time can be cut moment in
perforated while increasing a certain distance, then fell to the height of the
original, can avoid the slag splashing up appropriately cut mouth adhesion. 0 do
not use this function, the speed of P22 is used when lifting, and P04 speed is
used when descending, unit: seconds, setting range 0~ 2.
P22: dynamic perforation is rising faster, use with P21 P21 is zero this parameter
meaningless, because the motor for dc motor used this speed is greater than the
appropriate P04 speed, set the range 0 to 120.
P23: output 2 function definition, set to 0, output 2 is defined as the initial
location to complete the feedback signal, setting range 0~ 1.
P24: partial pressure ratio calibration, block and plasma display voltage difference
from the actual voltage can adjust the parameters, the numerical increase the
block shows the voltage increase, and vice, set range 32 ~ 255.
P26: upper and lower limit effective level, 0 low and effective, 1 high and
effective, if not used please set to 0.
P27: location switch effectively level, 0 is effective, 1 is effective.
P28: rise down effective level, 0 low effective, 1 high effective.
P29: corner signal effective level, 0 low and effective, 1 high and effective.