SF-HC25C3 Height Controller
15
function.
P18
5
0-2.0
Unit: second, time to introduce arc pressure
delay.
P19
0
0-9.9
Unit: seconds, starting up time, 0 do not use this
feature.
P20
0
0-9.9
Unit: seconds, turn off the arc time, 0 do not use
this function.
P21
0
0-9.9
Unit: second, dynamic punch rise time, 0 do not
use this feature.
P22
50
30-99 Dynamic piercing increases speed.
P23
1
0-1
Output 2 function definition.
P24
128
32-
255
Partial pressure ratio calibration, setting range of
32~ 255.
P26
0
0-1
Upper and lower limit effective level, 0 is
effective, 1 is effective.
P27
0
0-1
The positioning switch is effective level, low and
effective, 1 high and effective.
P28
0
0-1
The rise drop is effective level, 0 is effective, 1 is
effective.
P29
0
0-1
Corner signal effective level, 0 low and effective,
1 high efficiency.
P30
0
0-1
Arc signal effective level, 0 low and effective, 1
high and effective.
P31
1
0-1
The arc belt positioning movement, zero
positioning movement, 1 positioning movement.
Detailed description:
P00:0 do not save, 1 save, 2 restore user default, 3 restore factory default value, 4
save as user default value. When entering, display 6. In this interface, you can
also view the state of the input signal, and use 7 status indicators to represent
the state of 7 inputs, indicating that the corresponding input signal is connected
文件使用