SF-HC25C3 Height Controller
13
window above after the rotation shows that the value is about 3 seconds. After the timer
is finished, the arc pressure is show.
4.2
Parameter specification
the knob
”
GIVEN VOLTAGE
”
:
In the working condition of parameter setting: when
pressed, enter the menu cursor switch; When rotating, rotate counterclockwise
and rotate clockwise.
Press (GIVEN VOLTAGE) button 3 seconds to enter the parameter menu
without any action. The upper digital tube displays the parameter number and
flashes, rotating the (GIVEN VOLTAGE) knob can change the parameter number.
The number is 32 with P beginning, indicating P01~ P32. The digital tube below
shows the value of the current parameter number, with a maximum of three
digits. Click the (GIVEN VOLTAGE) button to switch to the display window below,
and rotate the setting of the arc knob to change the parameter value. Save and
exit the parameter menu at p00-001.
For example: modify manual ascent speed (P03) for 99.
1. Press (GIVEN VOLTAGE) button for 3 seconds and enter the parameter
Settings. The display window displays P01 and flashes, and the next window
shows 01.0.
2. Rotate (GIVEN VOLTAGE) knob to P03 and blink. The lower window
shows 080 (default).
3. Click (GIVEN VOLTAGE) button to switch the cursor, the upper window is
always bright, the next window is flashing.
4. Rotate (GIVEN VOLTAGE) knob to 099.
5. Click (GIVEN VOLTAGE) button to switch the cursor, the upper window
flicker and the window is always bright.
6. Rotate (GIVEN VOLTAGE) knob to P00.
7. Click (GIVEN VOLTAGE) button to switch the cursor, the upper window is
always bright, the next window is flashing.
8. Rotate (GIVEN VOLTAGE) knob to 001.
9. Press (GIVEN VOLTAGE) button to save and exit.
文件使用
"pdfFactory Pro"
试用版本创建