8. System Temperature Overheat and Fan Failure Management

If the alarm indicator has  lit up red and the audio alarm sounds, this could mean the system fan has  stopped 
operating entirely, the system temperature has exceeded over the default temperature of 60°C. Hard drive is 
not properly installed or system malfunction, When this  occurs, you may mute the audio alarm( refer to  the 
System Controls > View events > Mute Beeper ) to shut off the audio alarm and power off the system imme-
diately if in the allowed operational state then re-power on the system to double check and see if the problem 
is  still present. If the problem persists, please turn off the system and contact your supplier or the STARDOM 
tech support for further assistance.
If you require an host adapter  to be used with this  system, please log onto 

www.stardom.com.tw

 to find the 

recommended adapter or contact STARDOM for more information.

9. Visual Status Indicator Definitions

A. Voltage Indicator:

(1) When the LED indicator lights green, this means the power of the system is on.

(2) When the LED indicator is blink red, this means there is a voltage error. 

B. Temperature Indicator:

(1) When the LED indicator light green, this means the system is on normal status.

(2) This Led will blink red if the internal temperature rises above the Spec setting.

C. Fan Indicator:

(1) When the LED indicator light green, this means the system is on normal status.

(2) This Led will blink red if there is a fan problem.

D. Hard Drive Status Indicator:

(1) When the hard drive status indicator light green, this means the drive is present 

 

and is on idling.

(2) When the hard drive status indicator lights red twice per second, this means 

 

drive failure. 

(3) When the hard drive status indicator lights red four times per second, this 

 

means drive is a target disk of the rebuild situation.

10. 2.2TB Setting Instruction

Please pay attention, this process only can be worked with eSATA cable, and 64bit operating system.

1. GUI Instruction

Click  “Quick  Create”, find “Greater  2 TB Volume  Support”  and select “Yes”. Click  “Confirm The Operation” 
and press “Submit” to complete the setting process.

2. Disk Management

(1) After  complete RAID  setting, the hard drive will be divided into two parts  and show two disks  in the 

disk  management  column.  Please right click  on disk  1 and select  ”GPT Disk”  to combine these two 
disks.

(2) Format the disk to complete the process.

$

%

&

'

SOHORAID SR5 Series User Manual

17

Содержание Sohoraid SR5 Series

Страница 1: ...SR5 WBS2 Five Drive RAID Storage Enclosure...

Страница 2: ...SOHORAID SR5 Series User Manual...

Страница 3: ...e update please contact your local supplier or visit www stardom com tw for further information Copyright RAIDON TECHNOLOGY INC All rights reserved Table of Contents 1 Package Contents and Product Vie...

Страница 4: ...3OHDVH HQVXUH HDFK SOXJ LV SURSHUO FRQQHFWHG EHIRUH WXUQLQJ RQ WKH SRZHU Front View Rear View 1 Hard drive access indicator 2 Removable drive tray 3 Key access opening 4 Voltage level indicator 5 Temp...

Страница 5: ...om the removable tray then mount the hard drive onto the tray and se cure it with the screws enclosed in the accessories kit Once completed insert the drive tray back from the drive position and push...

Страница 6: ...anel mounted on the SR5 WBS2 is the primary user interface You can manage and setup the entire system using the LCD display and the four control buttons below it without using any other hardware or so...

Страница 7: ...stallation is complete log in by referring to the following instructions 1 Run the GUI Com2Http program define the necessary settings then check the Launching Web Browser when server started box Expla...

Страница 8: ...ress can t be acquired the SR5 WBS2 will automatically set an IP ad dress The default IP is 192 168 1 100 The IP address used will be automatically shown on the unit s LCD display You can access the l...

Страница 9: ...isk space C Initialization Mode includes the three options a Background Initialization It allows use of hard disk during Initialization but delivers lower efficiency b Foreground Initialization Use of...

Страница 10: ...k the Confirm The Operation box and then click Submit 4 The following screen will appear Initialization is finished 5 Please select Restart Controller under System Controls SOHORAID SR5 Series User Ma...

Страница 11: ...s completed 8 Connect SR5 WBS2 to the computer using the preferred interface connection 9 Wait for the system to complete initialization as the hard drive status indicator will briefly light up red th...

Страница 12: ...guration View Events Mute Beeper Generate Test Event Clear Event Buffer Modify Password Upgrade Firmware Restart Controller Raid Set Hierarchy Information System information Hardware Monitor When your...

Страница 13: ...ill complete the setup process Note 1 All physical drives will be included in the RAID set The RAID capacity will be calculated using the ac tual capacity of the smallest hard drive 2 This function wi...

Страница 14: ...ng with the expansion to avoid losing your data 5 3 4 Offline RAID Set This feature has been built through the established removable disk arrays facilitate you to conduct followup into a new set of di...

Страница 15: ...6 Spare 5 4 1 3 Stripe Size You can select 4K 8K 16K 32K 64K or 128K If you regularly read or write large files e g mpeg video files then you can use 128K for better performance If you mainly work wi...

Страница 16: ...the wrong HDD this function can be used to check that the correct HDD is currently selected Select this function then select the HDD to remove The LED light for the selected HDD will begin to blink 5...

Страница 17: ...n It includes following information RAID Set Hierarchy System Information Hardware Monitor 5 7 1 RAID Set Hierarchy Use this feature to view the current RAID set 5 7 2 Show System Information Shows al...

Страница 18: ...g has been completed the RAID system is ready for use Note The actual storage capacities may differ from the stated capacities on the hard drives once the drives have been formatted 7 Drive Failures a...

Страница 19: ...s a voltage error B Temperature Indicator 1 When the LED indicator light green this means the system is on normal status 2 This Led will blink red if the internal temperature rises above the Spec sett...

Страница 20: ...t RAID MODE and press ENTER 3 Press ESC is to set the volume supporting 2 2TB capacity press ENTER is to set the volume sup porting over 2 2TB capacity 4 Press ENTER to confirm the available volume 5...

Страница 21: ...Ver 1 0 www stardom com tw...

Отзывы: